Cargando…

Spectroscopic optical coherence elastography

We present an optical technique to image the frequency-dependent complex mechanical response of a viscoelastic sample. Three-dimensional hyperspectral data, comprising two-dimensional B-mode images and a third dimension corresponding to vibration frequency, were acquired from samples undergoing exte...

Descripción completa

Detalles Bibliográficos
Autores principales: Adie, Steven G., Liang, Xing, Kennedy, Brendan F., John, Renu, Sampson, David D., Boppart, Stephen A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3319753/
https://www.ncbi.nlm.nih.gov/pubmed/21164898
http://dx.doi.org/10.1364/OE.18.025519
_version_ 1782228748764971008
author Adie, Steven G.
Liang, Xing
Kennedy, Brendan F.
John, Renu
Sampson, David D.
Boppart, Stephen A.
author_facet Adie, Steven G.
Liang, Xing
Kennedy, Brendan F.
John, Renu
Sampson, David D.
Boppart, Stephen A.
author_sort Adie, Steven G.
collection PubMed
description We present an optical technique to image the frequency-dependent complex mechanical response of a viscoelastic sample. Three-dimensional hyperspectral data, comprising two-dimensional B-mode images and a third dimension corresponding to vibration frequency, were acquired from samples undergoing external mechanical excitation in the audio-frequency range. We describe the optical coherence tomography (OCT) signal when vibration is applied to a sample and detail the processing and acquisition techniques used to extract the local complex mechanical response from three-dimensional data that, due to a wide range of vibration frequencies, possess a wide range of sample velocities. We demonstrate frequency-dependent contrast of the displacement amplitude and phase of a silicone phantom containing inclusions of higher stiffness. Measurements of an ex vivo tumor margin demonstrate distinct spectra between adipose and tumor regions, and images of displacement amplitude and phase demonstrated spatially-resolved contrast. Contrast was also observed in displacement amplitude and phase images of a rat muscle sample. These results represent the first demonstration of mechanical spectroscopy based on B-mode OCT imaging. Spectroscopic optical coherence elastography (S-OCE) provides a high-resolution imaging capability for the detection of tissue pathologies that are characterized by a frequency-dependent viscoelastic response.
format Online
Article
Text
id pubmed-3319753
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-33197532012-04-04 Spectroscopic optical coherence elastography Adie, Steven G. Liang, Xing Kennedy, Brendan F. John, Renu Sampson, David D. Boppart, Stephen A. Opt Express Research-Article We present an optical technique to image the frequency-dependent complex mechanical response of a viscoelastic sample. Three-dimensional hyperspectral data, comprising two-dimensional B-mode images and a third dimension corresponding to vibration frequency, were acquired from samples undergoing external mechanical excitation in the audio-frequency range. We describe the optical coherence tomography (OCT) signal when vibration is applied to a sample and detail the processing and acquisition techniques used to extract the local complex mechanical response from three-dimensional data that, due to a wide range of vibration frequencies, possess a wide range of sample velocities. We demonstrate frequency-dependent contrast of the displacement amplitude and phase of a silicone phantom containing inclusions of higher stiffness. Measurements of an ex vivo tumor margin demonstrate distinct spectra between adipose and tumor regions, and images of displacement amplitude and phase demonstrated spatially-resolved contrast. Contrast was also observed in displacement amplitude and phase images of a rat muscle sample. These results represent the first demonstration of mechanical spectroscopy based on B-mode OCT imaging. Spectroscopic optical coherence elastography (S-OCE) provides a high-resolution imaging capability for the detection of tissue pathologies that are characterized by a frequency-dependent viscoelastic response. Optical Society of America 2010-11-22 /pmc/articles/PMC3319753/ /pubmed/21164898 http://dx.doi.org/10.1364/OE.18.025519 Text en ©2010 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Research-Article
Adie, Steven G.
Liang, Xing
Kennedy, Brendan F.
John, Renu
Sampson, David D.
Boppart, Stephen A.
Spectroscopic optical coherence elastography
title Spectroscopic optical coherence elastography
title_full Spectroscopic optical coherence elastography
title_fullStr Spectroscopic optical coherence elastography
title_full_unstemmed Spectroscopic optical coherence elastography
title_short Spectroscopic optical coherence elastography
title_sort spectroscopic optical coherence elastography
topic Research-Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3319753/
https://www.ncbi.nlm.nih.gov/pubmed/21164898
http://dx.doi.org/10.1364/OE.18.025519
work_keys_str_mv AT adiesteveng spectroscopicopticalcoherenceelastography
AT liangxing spectroscopicopticalcoherenceelastography
AT kennedybrendanf spectroscopicopticalcoherenceelastography
AT johnrenu spectroscopicopticalcoherenceelastography
AT sampsondavidd spectroscopicopticalcoherenceelastography
AT boppartstephena spectroscopicopticalcoherenceelastography