Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head

PURPOSE: To compare the performance of scanning laser topography (SLT) and scanning laser polarimetry (SLP) on the rim of the optic nerve head and its surrounding area and thereby to evaluate whether these imaging technologies are influenced by other factors beyond the thickness of the retinal nerve...

Descripción completa

Detalles Bibliográficos
Autores principales: Kremmer, Stephan, Keienburg, Marcus, Anastassiou, Gerasimos, Schallenberg, Maurice, Steuhl, Klaus-Peter, Selbach, J. Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3322449/
https://www.ncbi.nlm.nih.gov/pubmed/22496715
http://dx.doi.org/10.2174/1874364101206010006
_version_ 1782229067071750144
author Kremmer, Stephan
Keienburg, Marcus
Anastassiou, Gerasimos
Schallenberg, Maurice
Steuhl, Klaus-Peter
Selbach, J. Michael
author_facet Kremmer, Stephan
Keienburg, Marcus
Anastassiou, Gerasimos
Schallenberg, Maurice
Steuhl, Klaus-Peter
Selbach, J. Michael
author_sort Kremmer, Stephan
collection PubMed
description PURPOSE: To compare the performance of scanning laser topography (SLT) and scanning laser polarimetry (SLP) on the rim of the optic nerve head and its surrounding area and thereby to evaluate whether these imaging technologies are influenced by other factors beyond the thickness of the retinal nerve fiber layer (RNFL). MATERIALS AND METHODOLOGY: A total of 154 eyes from 5 different groups were examined: young healthy subjects (YNorm), old healthy subjects (ONorm), patients with normal tension glaucoma (NTG), patients with open-angle glaucoma and early glaucomatous damage (OAGE) and patients with open-angle glaucoma and advanced glaucomatous damage (OAGA). SLT and SLP measurements were taken. Four concentric circles were superimposed on each of the images: the first one measuring at the rim of the optic nerve head (1.0 ONHD), the next measuring at 1.25 optic nerve head diameters (ONHD), at 1.5 ONHD and at 1.75 ONHD. The aligned images were analyzed using GDx/NFA software. RESULTS: Both methods showed peaks of RNFL thickness in the superior and inferior segments of the ONH. The maximum thickness, registered by the SLT device was at the ONH rim where the SLP device tended to measure the lowest values. SLT measurements at the ONH were influenced by other tissues besides the RNFL like blood vessels and glial tissues. SLT and SLP were most strongly correlated at distances of 1.25 and 1.5 ONHD. CONCLUSIONS: While both imaging technologies are valuable tools in detecting glaucoma, measurements at the ONH rim should be interpreted critically since both methods might provide misleading results. For the assessment of the retinal nerve fiber layer we would like to recommend for both imaging technologies, SLT and SLP, measurements in 1.25 and 1.5 ONHD distance of the rim of the optic nerve head.
format Online
Article
Text
id pubmed-3322449
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-33224492012-04-11 Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head Kremmer, Stephan Keienburg, Marcus Anastassiou, Gerasimos Schallenberg, Maurice Steuhl, Klaus-Peter Selbach, J. Michael Open Ophthalmol J Article PURPOSE: To compare the performance of scanning laser topography (SLT) and scanning laser polarimetry (SLP) on the rim of the optic nerve head and its surrounding area and thereby to evaluate whether these imaging technologies are influenced by other factors beyond the thickness of the retinal nerve fiber layer (RNFL). MATERIALS AND METHODOLOGY: A total of 154 eyes from 5 different groups were examined: young healthy subjects (YNorm), old healthy subjects (ONorm), patients with normal tension glaucoma (NTG), patients with open-angle glaucoma and early glaucomatous damage (OAGE) and patients with open-angle glaucoma and advanced glaucomatous damage (OAGA). SLT and SLP measurements were taken. Four concentric circles were superimposed on each of the images: the first one measuring at the rim of the optic nerve head (1.0 ONHD), the next measuring at 1.25 optic nerve head diameters (ONHD), at 1.5 ONHD and at 1.75 ONHD. The aligned images were analyzed using GDx/NFA software. RESULTS: Both methods showed peaks of RNFL thickness in the superior and inferior segments of the ONH. The maximum thickness, registered by the SLT device was at the ONH rim where the SLP device tended to measure the lowest values. SLT measurements at the ONH were influenced by other tissues besides the RNFL like blood vessels and glial tissues. SLT and SLP were most strongly correlated at distances of 1.25 and 1.5 ONHD. CONCLUSIONS: While both imaging technologies are valuable tools in detecting glaucoma, measurements at the ONH rim should be interpreted critically since both methods might provide misleading results. For the assessment of the retinal nerve fiber layer we would like to recommend for both imaging technologies, SLT and SLP, measurements in 1.25 and 1.5 ONHD distance of the rim of the optic nerve head. Bentham Open 2012-03-22 /pmc/articles/PMC3322449/ /pubmed/22496715 http://dx.doi.org/10.2174/1874364101206010006 Text en © Kremmer et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Kremmer, Stephan
Keienburg, Marcus
Anastassiou, Gerasimos
Schallenberg, Maurice
Steuhl, Klaus-Peter
Selbach, J. Michael
Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head
title Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head
title_full Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head
title_fullStr Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head
title_full_unstemmed Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head
title_short Scanning Laser Topography and Scanning Laser Polarimetry: Comparing Both Imaging Methods at Same Distances from the Optic Nerve Head
title_sort scanning laser topography and scanning laser polarimetry: comparing both imaging methods at same distances from the optic nerve head
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3322449/
https://www.ncbi.nlm.nih.gov/pubmed/22496715
http://dx.doi.org/10.2174/1874364101206010006
work_keys_str_mv AT kremmerstephan scanninglasertopographyandscanninglaserpolarimetrycomparingbothimagingmethodsatsamedistancesfromtheopticnervehead
AT keienburgmarcus scanninglasertopographyandscanninglaserpolarimetrycomparingbothimagingmethodsatsamedistancesfromtheopticnervehead
AT anastassiougerasimos scanninglasertopographyandscanninglaserpolarimetrycomparingbothimagingmethodsatsamedistancesfromtheopticnervehead
AT schallenbergmaurice scanninglasertopographyandscanninglaserpolarimetrycomparingbothimagingmethodsatsamedistancesfromtheopticnervehead
AT steuhlklauspeter scanninglasertopographyandscanninglaserpolarimetrycomparingbothimagingmethodsatsamedistancesfromtheopticnervehead
AT selbachjmichael scanninglasertopographyandscanninglaserpolarimetrycomparingbothimagingmethodsatsamedistancesfromtheopticnervehead