Cargando…

Pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a Q-damped atomic force microscopy cantilever

The frequency-resolved viscoelasticity of a hydration layer on a mica surface was studied by pulse-response measurement of a magnetically driven atomic force microscopy cantilever. Resonant ringing of the cantilever due to its 1st and 2nd resonance modes was suppressed by means of the Q-control tech...

Descripción completa

Detalles Bibliográficos
Autor principal: Kageshima, Masami
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Beilstein-Institut 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3323915/
https://www.ncbi.nlm.nih.gov/pubmed/22496999
http://dx.doi.org/10.3762/bjnano.3.29
_version_ 1782229274057506816
author Kageshima, Masami
author_facet Kageshima, Masami
author_sort Kageshima, Masami
collection PubMed
description The frequency-resolved viscoelasticity of a hydration layer on a mica surface was studied by pulse-response measurement of a magnetically driven atomic force microscopy cantilever. Resonant ringing of the cantilever due to its 1st and 2nd resonance modes was suppressed by means of the Q-control technique. The Fourier–Laplace transform of the deflection signal of the cantilever gave the frequency-resolved complex compliance of the cantilever–sample system. The significant viscoelasticity spectrum of the hydration layer was successfully derived in a frequency range below 100 kHz by comparison of data obtained at a distance of 300 nm from the substrate with those taken in the proximity of the substrate. A positive value of the real part of the stiffness was determined and is attributed to the reported solidification of the hydration layers.
format Online
Article
Text
id pubmed-3323915
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Beilstein-Institut
record_format MEDLINE/PubMed
spelling pubmed-33239152012-04-11 Pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a Q-damped atomic force microscopy cantilever Kageshima, Masami Beilstein J Nanotechnol Full Research Paper The frequency-resolved viscoelasticity of a hydration layer on a mica surface was studied by pulse-response measurement of a magnetically driven atomic force microscopy cantilever. Resonant ringing of the cantilever due to its 1st and 2nd resonance modes was suppressed by means of the Q-control technique. The Fourier–Laplace transform of the deflection signal of the cantilever gave the frequency-resolved complex compliance of the cantilever–sample system. The significant viscoelasticity spectrum of the hydration layer was successfully derived in a frequency range below 100 kHz by comparison of data obtained at a distance of 300 nm from the substrate with those taken in the proximity of the substrate. A positive value of the real part of the stiffness was determined and is attributed to the reported solidification of the hydration layers. Beilstein-Institut 2012-03-19 /pmc/articles/PMC3323915/ /pubmed/22496999 http://dx.doi.org/10.3762/bjnano.3.29 Text en Copyright © 2012, Kageshima https://creativecommons.org/licenses/by/2.0https://www.beilstein-journals.org/bjnano/termsThis is an Open Access article under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The license is subject to the Beilstein Journal of Nanotechnology terms and conditions: (https://www.beilstein-journals.org/bjnano/terms)
spellingShingle Full Research Paper
Kageshima, Masami
Pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a Q-damped atomic force microscopy cantilever
title Pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a Q-damped atomic force microscopy cantilever
title_full Pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a Q-damped atomic force microscopy cantilever
title_fullStr Pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a Q-damped atomic force microscopy cantilever
title_full_unstemmed Pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a Q-damped atomic force microscopy cantilever
title_short Pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a Q-damped atomic force microscopy cantilever
title_sort pulse-response measurement of frequency-resolved water dynamics on a hydrophilic surface using a q-damped atomic force microscopy cantilever
topic Full Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3323915/
https://www.ncbi.nlm.nih.gov/pubmed/22496999
http://dx.doi.org/10.3762/bjnano.3.29
work_keys_str_mv AT kageshimamasami pulseresponsemeasurementoffrequencyresolvedwaterdynamicsonahydrophilicsurfaceusingaqdampedatomicforcemicroscopycantilever