Cargando…
Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography
Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitra...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Echocardiography
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3324729/ https://www.ncbi.nlm.nih.gov/pubmed/22509440 http://dx.doi.org/10.4250/jcu.2012.20.1.52 |
_version_ | 1782229345241137152 |
---|---|
author | Chung, Eui-Jong Kim, Tae-Yop Hwang, Jong Min Kim, Sang-Phil Yang, Hyun Suk |
author_facet | Chung, Eui-Jong Kim, Tae-Yop Hwang, Jong Min Kim, Sang-Phil Yang, Hyun Suk |
author_sort | Chung, Eui-Jong |
collection | PubMed |
description | Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images. |
format | Online Article Text |
id | pubmed-3324729 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Korean Society of Echocardiography |
record_format | MEDLINE/PubMed |
spelling | pubmed-33247292012-04-16 Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography Chung, Eui-Jong Kim, Tae-Yop Hwang, Jong Min Kim, Sang-Phil Yang, Hyun Suk J Cardiovasc Ultrasound Case Report Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images. Korean Society of Echocardiography 2012-03 2012-03-27 /pmc/articles/PMC3324729/ /pubmed/22509440 http://dx.doi.org/10.4250/jcu.2012.20.1.52 Text en Copyright © 2012 Korean Society of Echocardiography http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Chung, Eui-Jong Kim, Tae-Yop Hwang, Jong Min Kim, Sang-Phil Yang, Hyun Suk Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography |
title | Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography |
title_full | Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography |
title_fullStr | Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography |
title_full_unstemmed | Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography |
title_short | Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography |
title_sort | cases of hemolytic anemia with periprosthetic leaks evaluated by real-time 3-dimensional transesophageal echocardiography |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3324729/ https://www.ncbi.nlm.nih.gov/pubmed/22509440 http://dx.doi.org/10.4250/jcu.2012.20.1.52 |
work_keys_str_mv | AT chungeuijong casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography AT kimtaeyop casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography AT hwangjongmin casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography AT kimsangphil casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography AT yanghyunsuk casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography |