Cargando…

Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography

Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitra...

Descripción completa

Detalles Bibliográficos
Autores principales: Chung, Eui-Jong, Kim, Tae-Yop, Hwang, Jong Min, Kim, Sang-Phil, Yang, Hyun Suk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Echocardiography 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3324729/
https://www.ncbi.nlm.nih.gov/pubmed/22509440
http://dx.doi.org/10.4250/jcu.2012.20.1.52
_version_ 1782229345241137152
author Chung, Eui-Jong
Kim, Tae-Yop
Hwang, Jong Min
Kim, Sang-Phil
Yang, Hyun Suk
author_facet Chung, Eui-Jong
Kim, Tae-Yop
Hwang, Jong Min
Kim, Sang-Phil
Yang, Hyun Suk
author_sort Chung, Eui-Jong
collection PubMed
description Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images.
format Online
Article
Text
id pubmed-3324729
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Korean Society of Echocardiography
record_format MEDLINE/PubMed
spelling pubmed-33247292012-04-16 Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography Chung, Eui-Jong Kim, Tae-Yop Hwang, Jong Min Kim, Sang-Phil Yang, Hyun Suk J Cardiovasc Ultrasound Case Report Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images. Korean Society of Echocardiography 2012-03 2012-03-27 /pmc/articles/PMC3324729/ /pubmed/22509440 http://dx.doi.org/10.4250/jcu.2012.20.1.52 Text en Copyright © 2012 Korean Society of Echocardiography http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Chung, Eui-Jong
Kim, Tae-Yop
Hwang, Jong Min
Kim, Sang-Phil
Yang, Hyun Suk
Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography
title Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography
title_full Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography
title_fullStr Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography
title_full_unstemmed Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography
title_short Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography
title_sort cases of hemolytic anemia with periprosthetic leaks evaluated by real-time 3-dimensional transesophageal echocardiography
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3324729/
https://www.ncbi.nlm.nih.gov/pubmed/22509440
http://dx.doi.org/10.4250/jcu.2012.20.1.52
work_keys_str_mv AT chungeuijong casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography
AT kimtaeyop casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography
AT hwangjongmin casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography
AT kimsangphil casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography
AT yanghyunsuk casesofhemolyticanemiawithperiprostheticleaksevaluatedbyrealtime3dimensionaltransesophagealechocardiography