Cargando…

Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula

Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to t...

Descripción completa

Detalles Bibliográficos
Autores principales: Sierraalta, Marianella, Vivas, Jose L., Razzoog, Michael E., Wang, Rui-Feng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3328952/
https://www.ncbi.nlm.nih.gov/pubmed/22550486
http://dx.doi.org/10.1155/2012/374315
_version_ 1782229791590580224
author Sierraalta, Marianella
Vivas, Jose L.
Razzoog, Michael E.
Wang, Rui-Feng
author_facet Sierraalta, Marianella
Vivas, Jose L.
Razzoog, Michael E.
Wang, Rui-Feng
author_sort Sierraalta, Marianella
collection PubMed
description Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single edentulous CAD/CAM surgical guide were separated in two groups and resin patterns simulating the framework for a fixed complete denture developed. Five casts were sent to dental laboratories to invest, cast in a Palladium-Gold alloy and fit the framework. Ten casts had the resin pattern scanned for fabrication of milled bars in Titanium. Using measuring software, positions of implant replicas in the definitive model were recorded. The three dimensional spatial orientation of each implant replica was matched to the implant replica. Results. Results demonstrated the mean vertical gap of the Cast framework was 0.021 (+0.004) mm and 0.012 (0.002) mm determined by fixed and unfixed best-fit matching coordinate system. For Titanium frameworks they were 0.0037 (+0.0028) mm and 0.0024 (+0.0005) mm, respectively. Conclusions. Milled one-piece Titanium fixed complete denture frameworks provided a more accurate precision of fit then traditional cast frameworks.
format Online
Article
Text
id pubmed-3328952
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33289522012-05-01 Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula Sierraalta, Marianella Vivas, Jose L. Razzoog, Michael E. Wang, Rui-Feng Int J Dent Research Article Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single edentulous CAD/CAM surgical guide were separated in two groups and resin patterns simulating the framework for a fixed complete denture developed. Five casts were sent to dental laboratories to invest, cast in a Palladium-Gold alloy and fit the framework. Ten casts had the resin pattern scanned for fabrication of milled bars in Titanium. Using measuring software, positions of implant replicas in the definitive model were recorded. The three dimensional spatial orientation of each implant replica was matched to the implant replica. Results. Results demonstrated the mean vertical gap of the Cast framework was 0.021 (+0.004) mm and 0.012 (0.002) mm determined by fixed and unfixed best-fit matching coordinate system. For Titanium frameworks they were 0.0037 (+0.0028) mm and 0.0024 (+0.0005) mm, respectively. Conclusions. Milled one-piece Titanium fixed complete denture frameworks provided a more accurate precision of fit then traditional cast frameworks. Hindawi Publishing Corporation 2012 2012-04-08 /pmc/articles/PMC3328952/ /pubmed/22550486 http://dx.doi.org/10.1155/2012/374315 Text en Copyright © 2012 Marianella Sierraalta et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sierraalta, Marianella
Vivas, Jose L.
Razzoog, Michael E.
Wang, Rui-Feng
Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
title Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
title_full Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
title_fullStr Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
title_full_unstemmed Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
title_short Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
title_sort precision of fit of titanium and cast implant frameworks using a new matching formula
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3328952/
https://www.ncbi.nlm.nih.gov/pubmed/22550486
http://dx.doi.org/10.1155/2012/374315
work_keys_str_mv AT sierraaltamarianella precisionoffitoftitaniumandcastimplantframeworksusinganewmatchingformula
AT vivasjosel precisionoffitoftitaniumandcastimplantframeworksusinganewmatchingformula
AT razzoogmichaele precisionoffitoftitaniumandcastimplantframeworksusinganewmatchingformula
AT wangruifeng precisionoffitoftitaniumandcastimplantframeworksusinganewmatchingformula