Cargando…

Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices

BACKGROUND: In the context of a potential bioterrorist attack sensitive and fast detection of functionally active toxins such as ricin from complex matrices is necessary to be able to start timely countermeasures. One of the functional detection methods currently available for ricin is the endpoint...

Descripción completa

Detalles Bibliográficos
Autores principales: Pauly, Diana, Worbs, Sylvia, Kirchner, Sebastian, Shatohina, Olena, Dorner, Martin B., Dorner, Brigitte G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3330811/
https://www.ncbi.nlm.nih.gov/pubmed/22532852
http://dx.doi.org/10.1371/journal.pone.0035360
_version_ 1782229959098499072
author Pauly, Diana
Worbs, Sylvia
Kirchner, Sebastian
Shatohina, Olena
Dorner, Martin B.
Dorner, Brigitte G.
author_facet Pauly, Diana
Worbs, Sylvia
Kirchner, Sebastian
Shatohina, Olena
Dorner, Martin B.
Dorner, Brigitte G.
author_sort Pauly, Diana
collection PubMed
description BACKGROUND: In the context of a potential bioterrorist attack sensitive and fast detection of functionally active toxins such as ricin from complex matrices is necessary to be able to start timely countermeasures. One of the functional detection methods currently available for ricin is the endpoint cytotoxicity assay, which suffers from a number of technical deficits. METHODOLOGY/FINDINGS: This work describes a novel online cytotoxicity assay for the detection of active ricin and Ricinus communis agglutinin, that is based on a real-time cell electronic sensing system and impedance measurement. Characteristic growth parameters of Vero cells were monitored online and used as standardized viability control. Upon incubation with toxin the cell status and the cytotoxic effect were visualized using a characteristic cell index–time profile. For ricin, tested in concentrations of 0.06 ng/mL or above, a concentration-dependent decrease of cell index correlating with cytotoxicity was recorded between 3.5 h and 60 h. For ricin, sensitive detection was determined after 24 h, with an IC50 of 0.4 ng/mL (for agglutinin, an IC50 of 30 ng/mL was observed). Using functionally blocking antibodies, the specificity for ricin and agglutinin was shown. For detection from complex matrices, ricin was spiked into several food matrices, and an IC50 ranging from 5.6 to 200 ng/mL was observed. Additionally, the assay proved to be useful in detecting active ricin in environmental sample materials, as shown for organic fertilizer containing R. communis material. CONCLUSIONS/SIGNIFICANCE: The cell-electrode impedance measurement provides a sensitive online detection method for biologically active cytotoxins such as ricin. As the cell status is monitored online, the assay can be standardized more efficiently than previous approaches based on endpoint measurement. More importantly, the real-time cytotoxicity assay provides a fast and easy tool to detect active ricin in complex sample matrices.
format Online
Article
Text
id pubmed-3330811
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-33308112012-04-24 Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices Pauly, Diana Worbs, Sylvia Kirchner, Sebastian Shatohina, Olena Dorner, Martin B. Dorner, Brigitte G. PLoS One Research Article BACKGROUND: In the context of a potential bioterrorist attack sensitive and fast detection of functionally active toxins such as ricin from complex matrices is necessary to be able to start timely countermeasures. One of the functional detection methods currently available for ricin is the endpoint cytotoxicity assay, which suffers from a number of technical deficits. METHODOLOGY/FINDINGS: This work describes a novel online cytotoxicity assay for the detection of active ricin and Ricinus communis agglutinin, that is based on a real-time cell electronic sensing system and impedance measurement. Characteristic growth parameters of Vero cells were monitored online and used as standardized viability control. Upon incubation with toxin the cell status and the cytotoxic effect were visualized using a characteristic cell index–time profile. For ricin, tested in concentrations of 0.06 ng/mL or above, a concentration-dependent decrease of cell index correlating with cytotoxicity was recorded between 3.5 h and 60 h. For ricin, sensitive detection was determined after 24 h, with an IC50 of 0.4 ng/mL (for agglutinin, an IC50 of 30 ng/mL was observed). Using functionally blocking antibodies, the specificity for ricin and agglutinin was shown. For detection from complex matrices, ricin was spiked into several food matrices, and an IC50 ranging from 5.6 to 200 ng/mL was observed. Additionally, the assay proved to be useful in detecting active ricin in environmental sample materials, as shown for organic fertilizer containing R. communis material. CONCLUSIONS/SIGNIFICANCE: The cell-electrode impedance measurement provides a sensitive online detection method for biologically active cytotoxins such as ricin. As the cell status is monitored online, the assay can be standardized more efficiently than previous approaches based on endpoint measurement. More importantly, the real-time cytotoxicity assay provides a fast and easy tool to detect active ricin in complex sample matrices. Public Library of Science 2012-04-19 /pmc/articles/PMC3330811/ /pubmed/22532852 http://dx.doi.org/10.1371/journal.pone.0035360 Text en Pauly et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Pauly, Diana
Worbs, Sylvia
Kirchner, Sebastian
Shatohina, Olena
Dorner, Martin B.
Dorner, Brigitte G.
Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices
title Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices
title_full Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices
title_fullStr Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices
title_full_unstemmed Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices
title_short Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices
title_sort real-time cytotoxicity assay for rapid and sensitive detection of ricin from complex matrices
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3330811/
https://www.ncbi.nlm.nih.gov/pubmed/22532852
http://dx.doi.org/10.1371/journal.pone.0035360
work_keys_str_mv AT paulydiana realtimecytotoxicityassayforrapidandsensitivedetectionofricinfromcomplexmatrices
AT worbssylvia realtimecytotoxicityassayforrapidandsensitivedetectionofricinfromcomplexmatrices
AT kirchnersebastian realtimecytotoxicityassayforrapidandsensitivedetectionofricinfromcomplexmatrices
AT shatohinaolena realtimecytotoxicityassayforrapidandsensitivedetectionofricinfromcomplexmatrices
AT dornermartinb realtimecytotoxicityassayforrapidandsensitivedetectionofricinfromcomplexmatrices
AT dornerbrigitteg realtimecytotoxicityassayforrapidandsensitivedetectionofricinfromcomplexmatrices