Cargando…

Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease

Patient awareness and concern regarding the potential health risks from ionizing radiation have peaked recently (Coakley et al., 2011) following widespread press and media coverage of the projected cancer risks from the increasing use of computed tomography (CT) (Berrington et al., 2007). The typica...

Descripción completa

Detalles Bibliográficos
Autores principales: Mc Laughlin, Patrick D., O'Connor, Owen J., O'Neill, Siobhán B., Shanahan, Fergus, Maher, Michael M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scholarly Research Network 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3332204/
https://www.ncbi.nlm.nih.gov/pubmed/22577571
http://dx.doi.org/10.5402/2012/790279
_version_ 1782230194821529600
author Mc Laughlin, Patrick D.
O'Connor, Owen J.
O'Neill, Siobhán B.
Shanahan, Fergus
Maher, Michael M.
author_facet Mc Laughlin, Patrick D.
O'Connor, Owen J.
O'Neill, Siobhán B.
Shanahan, Fergus
Maher, Michael M.
author_sort Mc Laughlin, Patrick D.
collection PubMed
description Patient awareness and concern regarding the potential health risks from ionizing radiation have peaked recently (Coakley et al., 2011) following widespread press and media coverage of the projected cancer risks from the increasing use of computed tomography (CT) (Berrington et al., 2007). The typical young and educated patient with inflammatory bowel disease (IBD) may in particular be conscious of his/her exposure to ionising radiation as a result of diagnostic imaging. Cumulative effective doses (CEDs) in patients with IBD have been reported as being high and are rising, primarily due to the more widespread and repeated use of CT (Desmond et al., 2008). Radiologists, technologists, and referring physicians have a responsibility to firstly counsel their patients accurately regarding the actual risks of ionizing radiation exposure; secondly to limit the use of those imaging modalities which involve ionising radiation to clinical situations where they are likely to change management; thirdly to ensure that a diagnostic quality imaging examination is acquired with lowest possible radiation exposure. In this paper, we synopsize available evidence related to radiation exposure and risk and we report advances in low-dose CT technology and examine the role for alternative imaging modalities such as ultrasonography or magnetic resonance imaging which avoid radiation exposure.
format Online
Article
Text
id pubmed-3332204
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher International Scholarly Research Network
record_format MEDLINE/PubMed
spelling pubmed-33322042012-05-10 Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease Mc Laughlin, Patrick D. O'Connor, Owen J. O'Neill, Siobhán B. Shanahan, Fergus Maher, Michael M. ISRN Gastroenterol Review Article Patient awareness and concern regarding the potential health risks from ionizing radiation have peaked recently (Coakley et al., 2011) following widespread press and media coverage of the projected cancer risks from the increasing use of computed tomography (CT) (Berrington et al., 2007). The typical young and educated patient with inflammatory bowel disease (IBD) may in particular be conscious of his/her exposure to ionising radiation as a result of diagnostic imaging. Cumulative effective doses (CEDs) in patients with IBD have been reported as being high and are rising, primarily due to the more widespread and repeated use of CT (Desmond et al., 2008). Radiologists, technologists, and referring physicians have a responsibility to firstly counsel their patients accurately regarding the actual risks of ionizing radiation exposure; secondly to limit the use of those imaging modalities which involve ionising radiation to clinical situations where they are likely to change management; thirdly to ensure that a diagnostic quality imaging examination is acquired with lowest possible radiation exposure. In this paper, we synopsize available evidence related to radiation exposure and risk and we report advances in low-dose CT technology and examine the role for alternative imaging modalities such as ultrasonography or magnetic resonance imaging which avoid radiation exposure. International Scholarly Research Network 2012-04-10 /pmc/articles/PMC3332204/ /pubmed/22577571 http://dx.doi.org/10.5402/2012/790279 Text en Copyright © 2012 Patrick D. Mc Laughlin et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Mc Laughlin, Patrick D.
O'Connor, Owen J.
O'Neill, Siobhán B.
Shanahan, Fergus
Maher, Michael M.
Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease
title Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease
title_full Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease
title_fullStr Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease
title_full_unstemmed Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease
title_short Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease
title_sort minimization of radiation exposure due to computed tomography in inflammatory bowel disease
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3332204/
https://www.ncbi.nlm.nih.gov/pubmed/22577571
http://dx.doi.org/10.5402/2012/790279
work_keys_str_mv AT mclaughlinpatrickd minimizationofradiationexposureduetocomputedtomographyininflammatoryboweldisease
AT oconnorowenj minimizationofradiationexposureduetocomputedtomographyininflammatoryboweldisease
AT oneillsiobhanb minimizationofradiationexposureduetocomputedtomographyininflammatoryboweldisease
AT shanahanfergus minimizationofradiationexposureduetocomputedtomographyininflammatoryboweldisease
AT mahermichaelm minimizationofradiationexposureduetocomputedtomographyininflammatoryboweldisease