Cargando…

Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used

Detalles Bibliográficos
Autores principales: Mateo, Jose, Paniagua, Pilar, Koller, Tobias, Moral, Victoria, Fontcuberta, Jordi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3334723/
https://www.ncbi.nlm.nih.gov/pubmed/21958443
http://dx.doi.org/10.1186/cc10304
_version_ 1782230671978135552
author Mateo, Jose
Paniagua, Pilar
Koller, Tobias
Moral, Victoria
Fontcuberta, Jordi
author_facet Mateo, Jose
Paniagua, Pilar
Koller, Tobias
Moral, Victoria
Fontcuberta, Jordi
author_sort Mateo, Jose
collection PubMed
description
format Online
Article
Text
id pubmed-3334723
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33347232012-09-12 Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used Mateo, Jose Paniagua, Pilar Koller, Tobias Moral, Victoria Fontcuberta, Jordi Crit Care Letter BioMed Central 2011 2011-09-12 /pmc/articles/PMC3334723/ /pubmed/21958443 http://dx.doi.org/10.1186/cc10304 Text en Copyright ©2011 BioMed Central Ltd
spellingShingle Letter
Mateo, Jose
Paniagua, Pilar
Koller, Tobias
Moral, Victoria
Fontcuberta, Jordi
Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used
title Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used
title_full Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used
title_fullStr Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used
title_full_unstemmed Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used
title_short Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used
title_sort dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if clauss method with mechanical clot detection is used
topic Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3334723/
https://www.ncbi.nlm.nih.gov/pubmed/21958443
http://dx.doi.org/10.1186/cc10304
work_keys_str_mv AT mateojose dextranandhydroxyethylstarchdonotinterferewithfibrinogenmeasurementifclaussmethodwithmechanicalclotdetectionisused
AT paniaguapilar dextranandhydroxyethylstarchdonotinterferewithfibrinogenmeasurementifclaussmethodwithmechanicalclotdetectionisused
AT kollertobias dextranandhydroxyethylstarchdonotinterferewithfibrinogenmeasurementifclaussmethodwithmechanicalclotdetectionisused
AT moralvictoria dextranandhydroxyethylstarchdonotinterferewithfibrinogenmeasurementifclaussmethodwithmechanicalclotdetectionisused
AT fontcubertajordi dextranandhydroxyethylstarchdonotinterferewithfibrinogenmeasurementifclaussmethodwithmechanicalclotdetectionisused