Cargando…

Airway response to acute mechanical stress in a human bronchial model of stretch

INTRODUCTION: Lung inflation may have deleterious effects on the alveoli during mechanical ventilation. However, the consequences of stretch during excessive lung inflation on basal tone and responsiveness of human bronchi are unknown. This study was undertaken to devise an experimental model of acu...

Descripción completa

Detalles Bibliográficos
Autores principales: Faisy, Christophe, Pinto, Francisco M, Le Guen, Morgan, Naline, Emmanuel, Delyle, Stanislas Grassin, Sage, Edouard, Candenas, Maria-Luz, Devillier, Philippe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3334752/
https://www.ncbi.nlm.nih.gov/pubmed/21914176
http://dx.doi.org/10.1186/cc10443
_version_ 1782230678635544576
author Faisy, Christophe
Pinto, Francisco M
Le Guen, Morgan
Naline, Emmanuel
Delyle, Stanislas Grassin
Sage, Edouard
Candenas, Maria-Luz
Devillier, Philippe
author_facet Faisy, Christophe
Pinto, Francisco M
Le Guen, Morgan
Naline, Emmanuel
Delyle, Stanislas Grassin
Sage, Edouard
Candenas, Maria-Luz
Devillier, Philippe
author_sort Faisy, Christophe
collection PubMed
description INTRODUCTION: Lung inflation may have deleterious effects on the alveoli during mechanical ventilation. However, the consequences of stretch during excessive lung inflation on basal tone and responsiveness of human bronchi are unknown. This study was undertaken to devise an experimental model of acute mechanical stretch in isolated human bronchi and to investigate its effect on airway tone and responsiveness. METHODS: Bronchi were removed from 48 thoracic surgery patients. After preparation and equilibration in an organ bath, bronchial rings were stretched for 5 min using a force (2.5 × basal tone) that corresponded to airway-inflation pressure > 30 cm H(2)O. The consequences of stretch were examined by using functional experiments, analysis of organ-bath fluid, and ribonucleic acid (RNA) isolation from tissue samples. RESULTS: Following removal of the applied force the airways immediately developed an increase in basal tone (P < 0.0001 vs. paired controls) that was sustained and it did so without significantly increasing responsiveness to acetylcholine. The spontaneous tone was abolished with a Rho-kinase inhibitor and epithelium removal, a leukotriene antagonist or nitric oxide synthase inhibitors reduced it, whereas indomethacin, sensory nerve inhibitors or antagonists for muscarinic, endothelin and histamine receptors had no effect. Stretch enhanced leukotriene-E(4 )production during the immediate spontaneous contraction of human bronchi (P < 0.05). Moreover, stretch up-regulated the early mRNA expression of genes involved in wingless-type mouse mammary tumor virus integration-site family (WNT)-signaling and Rho-kinase pathways. CONCLUSIONS: Stretching human bronchi for only 5 min induces epithelial leukotriene release via nitric oxide synthase activation and provokes a myogenic response dependent on Rho-kinase and WNT-signaling pathways. From a clinical perspective, these findings highlight the response of human airway to acute mechanical stress during excessive pulmonary inflation.
format Online
Article
Text
id pubmed-3334752
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33347522012-04-25 Airway response to acute mechanical stress in a human bronchial model of stretch Faisy, Christophe Pinto, Francisco M Le Guen, Morgan Naline, Emmanuel Delyle, Stanislas Grassin Sage, Edouard Candenas, Maria-Luz Devillier, Philippe Crit Care Research INTRODUCTION: Lung inflation may have deleterious effects on the alveoli during mechanical ventilation. However, the consequences of stretch during excessive lung inflation on basal tone and responsiveness of human bronchi are unknown. This study was undertaken to devise an experimental model of acute mechanical stretch in isolated human bronchi and to investigate its effect on airway tone and responsiveness. METHODS: Bronchi were removed from 48 thoracic surgery patients. After preparation and equilibration in an organ bath, bronchial rings were stretched for 5 min using a force (2.5 × basal tone) that corresponded to airway-inflation pressure > 30 cm H(2)O. The consequences of stretch were examined by using functional experiments, analysis of organ-bath fluid, and ribonucleic acid (RNA) isolation from tissue samples. RESULTS: Following removal of the applied force the airways immediately developed an increase in basal tone (P < 0.0001 vs. paired controls) that was sustained and it did so without significantly increasing responsiveness to acetylcholine. The spontaneous tone was abolished with a Rho-kinase inhibitor and epithelium removal, a leukotriene antagonist or nitric oxide synthase inhibitors reduced it, whereas indomethacin, sensory nerve inhibitors or antagonists for muscarinic, endothelin and histamine receptors had no effect. Stretch enhanced leukotriene-E(4 )production during the immediate spontaneous contraction of human bronchi (P < 0.05). Moreover, stretch up-regulated the early mRNA expression of genes involved in wingless-type mouse mammary tumor virus integration-site family (WNT)-signaling and Rho-kinase pathways. CONCLUSIONS: Stretching human bronchi for only 5 min induces epithelial leukotriene release via nitric oxide synthase activation and provokes a myogenic response dependent on Rho-kinase and WNT-signaling pathways. From a clinical perspective, these findings highlight the response of human airway to acute mechanical stress during excessive pulmonary inflation. BioMed Central 2011 2011-09-13 /pmc/articles/PMC3334752/ /pubmed/21914176 http://dx.doi.org/10.1186/cc10443 Text en Copyright ©2011 Faisy et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Faisy, Christophe
Pinto, Francisco M
Le Guen, Morgan
Naline, Emmanuel
Delyle, Stanislas Grassin
Sage, Edouard
Candenas, Maria-Luz
Devillier, Philippe
Airway response to acute mechanical stress in a human bronchial model of stretch
title Airway response to acute mechanical stress in a human bronchial model of stretch
title_full Airway response to acute mechanical stress in a human bronchial model of stretch
title_fullStr Airway response to acute mechanical stress in a human bronchial model of stretch
title_full_unstemmed Airway response to acute mechanical stress in a human bronchial model of stretch
title_short Airway response to acute mechanical stress in a human bronchial model of stretch
title_sort airway response to acute mechanical stress in a human bronchial model of stretch
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3334752/
https://www.ncbi.nlm.nih.gov/pubmed/21914176
http://dx.doi.org/10.1186/cc10443
work_keys_str_mv AT faisychristophe airwayresponsetoacutemechanicalstressinahumanbronchialmodelofstretch
AT pintofranciscom airwayresponsetoacutemechanicalstressinahumanbronchialmodelofstretch
AT leguenmorgan airwayresponsetoacutemechanicalstressinahumanbronchialmodelofstretch
AT nalineemmanuel airwayresponsetoacutemechanicalstressinahumanbronchialmodelofstretch
AT delylestanislasgrassin airwayresponsetoacutemechanicalstressinahumanbronchialmodelofstretch
AT sageedouard airwayresponsetoacutemechanicalstressinahumanbronchialmodelofstretch
AT candenasmarialuz airwayresponsetoacutemechanicalstressinahumanbronchialmodelofstretch
AT devillierphilippe airwayresponsetoacutemechanicalstressinahumanbronchialmodelofstretch