Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units

Background: Currently, to our knowledge, quality of output water of dental chair units is not covered by specific regulations in the European Union, and national recommendations are heterogeneous. In Germany, water used in dental chair units must follow drinking water quality. In the United States o...

Descripción completa

Detalles Bibliográficos
Autores principales: Bristela, Margit, Skolka, Astrid, Schmid-Schwap, Martina, Piehslinger, Eva, Indra, Alexander, Wewalka, Günther, Stauffer, Fritz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: German Medical Science GMS Publishing House 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3334951/
https://www.ncbi.nlm.nih.gov/pubmed/22558046
http://dx.doi.org/10.3205/dgkh000196
_version_ 1782230713714606080
author Bristela, Margit
Skolka, Astrid
Schmid-Schwap, Martina
Piehslinger, Eva
Indra, Alexander
Wewalka, Günther
Stauffer, Fritz
author_facet Bristela, Margit
Skolka, Astrid
Schmid-Schwap, Martina
Piehslinger, Eva
Indra, Alexander
Wewalka, Günther
Stauffer, Fritz
author_sort Bristela, Margit
collection PubMed
description Background: Currently, to our knowledge, quality of output water of dental chair units is not covered by specific regulations in the European Union, and national recommendations are heterogeneous. In Germany, water used in dental chair units must follow drinking water quality. In the United States of America, testing for aerobic heterotrophic bacteria is recommended. The present study was performed to evaluate whether the counts of aerobic heterotrophic bacteria correlate with the presence of potentially pathogenic bacteria such as Legionella spp. or Pseudomonas aeruginosa. Methods: 71 samples were collected from 26 dental chair units with integrated disinfection device and 31 samples from 15 outlets of the water distribution pipework within the department were examined. Samples were tested for aerobic heterotrophic bacteria at 35°C and 22°C using different culture media and for Legionella spp. and for Pseudomonas aeruginosa. Additionally, strains of Legionella pneumophila serogroup 1 were typed with monoclonal antibodies and representative samples of Legionella pneumophila serogroup 1 were typed by sequence based typing. Results: Our results showed a correlation between different agars for aerobic heterotrophic bacteria but no correlation for the count of aerobic heterotrophic bacteria and the presence of Legionella spp. or Pseudomonas aeruginosa. Conclusion: Testing for aerobic heterotrophic bacteria in output water or water distribution pipework within the departments alone is without any value for predicting whether the water is contaminated with potentially pathogenic bacteria like Legionella spp. or Pseudomonas aeruginosa.
format Online
Article
Text
id pubmed-3334951
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher German Medical Science GMS Publishing House
record_format MEDLINE/PubMed
spelling pubmed-33349512012-05-03 Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units Bristela, Margit Skolka, Astrid Schmid-Schwap, Martina Piehslinger, Eva Indra, Alexander Wewalka, Günther Stauffer, Fritz GMS Krankenhhyg Interdiszip Article Background: Currently, to our knowledge, quality of output water of dental chair units is not covered by specific regulations in the European Union, and national recommendations are heterogeneous. In Germany, water used in dental chair units must follow drinking water quality. In the United States of America, testing for aerobic heterotrophic bacteria is recommended. The present study was performed to evaluate whether the counts of aerobic heterotrophic bacteria correlate with the presence of potentially pathogenic bacteria such as Legionella spp. or Pseudomonas aeruginosa. Methods: 71 samples were collected from 26 dental chair units with integrated disinfection device and 31 samples from 15 outlets of the water distribution pipework within the department were examined. Samples were tested for aerobic heterotrophic bacteria at 35°C and 22°C using different culture media and for Legionella spp. and for Pseudomonas aeruginosa. Additionally, strains of Legionella pneumophila serogroup 1 were typed with monoclonal antibodies and representative samples of Legionella pneumophila serogroup 1 were typed by sequence based typing. Results: Our results showed a correlation between different agars for aerobic heterotrophic bacteria but no correlation for the count of aerobic heterotrophic bacteria and the presence of Legionella spp. or Pseudomonas aeruginosa. Conclusion: Testing for aerobic heterotrophic bacteria in output water or water distribution pipework within the departments alone is without any value for predicting whether the water is contaminated with potentially pathogenic bacteria like Legionella spp. or Pseudomonas aeruginosa. German Medical Science GMS Publishing House 2012-04-04 /pmc/articles/PMC3334951/ /pubmed/22558046 http://dx.doi.org/10.3205/dgkh000196 Text en Copyright © 2012 Bristela et al. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.en). You are free to copy, distribute and transmit the work, provided the original author and source are credited.
spellingShingle Article
Bristela, Margit
Skolka, Astrid
Schmid-Schwap, Martina
Piehslinger, Eva
Indra, Alexander
Wewalka, Günther
Stauffer, Fritz
Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units
title Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units
title_full Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units
title_fullStr Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units
title_full_unstemmed Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units
title_short Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units
title_sort testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3334951/
https://www.ncbi.nlm.nih.gov/pubmed/22558046
http://dx.doi.org/10.3205/dgkh000196
work_keys_str_mv AT bristelamargit testingforaerobicheterotrophicbacteriaallowsnopredictionofcontaminationwithpotentiallypathogenicbacteriaintheoutputwaterofdentalchairunits
AT skolkaastrid testingforaerobicheterotrophicbacteriaallowsnopredictionofcontaminationwithpotentiallypathogenicbacteriaintheoutputwaterofdentalchairunits
AT schmidschwapmartina testingforaerobicheterotrophicbacteriaallowsnopredictionofcontaminationwithpotentiallypathogenicbacteriaintheoutputwaterofdentalchairunits
AT piehslingereva testingforaerobicheterotrophicbacteriaallowsnopredictionofcontaminationwithpotentiallypathogenicbacteriaintheoutputwaterofdentalchairunits
AT indraalexander testingforaerobicheterotrophicbacteriaallowsnopredictionofcontaminationwithpotentiallypathogenicbacteriaintheoutputwaterofdentalchairunits
AT wewalkagunther testingforaerobicheterotrophicbacteriaallowsnopredictionofcontaminationwithpotentiallypathogenicbacteriaintheoutputwaterofdentalchairunits
AT staufferfritz testingforaerobicheterotrophicbacteriaallowsnopredictionofcontaminationwithpotentiallypathogenicbacteriaintheoutputwaterofdentalchairunits