Cargando…
Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study
A simple, sensitive, and rapid HPLC-MS/MS method was developed and validated for quantitative estimation of memantine in human plasma. Chromatography was performed on Zorbax SB-C(18) (4.6 × 75 mm, 3.5 μm) column. Memantine (ME) and internal standard Memantine-d6(MED6) were extracted by using liquid-...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3335321/ https://www.ncbi.nlm.nih.gov/pubmed/22567548 http://dx.doi.org/10.1155/2012/101249 |
_version_ | 1782230778891993088 |
---|---|
author | Konda, Ravi Kumar Challa, B. R. Chandu, Babu Rao Chandrasekhar, Kothapalli B. |
author_facet | Konda, Ravi Kumar Challa, B. R. Chandu, Babu Rao Chandrasekhar, Kothapalli B. |
author_sort | Konda, Ravi Kumar |
collection | PubMed |
description | A simple, sensitive, and rapid HPLC-MS/MS method was developed and validated for quantitative estimation of memantine in human plasma. Chromatography was performed on Zorbax SB-C(18) (4.6 × 75 mm, 3.5 μm) column. Memantine (ME) and internal standard Memantine-d6(MED6) were extracted by using liquid-liquid extraction and analyzed by LC-ESI-MS/MS using multiple-reaction monitoring (MRM) mode. The assay exhibited a linear dynamic range of 50.00–50000.00 pg/ml for ME in human plasma. This method demonstrated an intra- and interday precision within the range of 2.1–3.7 and 1.4–7.8%, respectively. Further intra- and interday accuracy was within the range of 95.6–99.8 and 95.7–99.1% correspondingly. The mean recovery of ME and MED6 was 86.07 ± 6.87 and 80.31 ± 5.70%, respectively. The described method was successfully employed in bioequivalence study of ME in Indian male healthy human volunteers under fasting conditions. |
format | Online Article Text |
id | pubmed-3335321 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-33353212012-05-07 Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study Konda, Ravi Kumar Challa, B. R. Chandu, Babu Rao Chandrasekhar, Kothapalli B. J Anal Methods Chem Research Article A simple, sensitive, and rapid HPLC-MS/MS method was developed and validated for quantitative estimation of memantine in human plasma. Chromatography was performed on Zorbax SB-C(18) (4.6 × 75 mm, 3.5 μm) column. Memantine (ME) and internal standard Memantine-d6(MED6) were extracted by using liquid-liquid extraction and analyzed by LC-ESI-MS/MS using multiple-reaction monitoring (MRM) mode. The assay exhibited a linear dynamic range of 50.00–50000.00 pg/ml for ME in human plasma. This method demonstrated an intra- and interday precision within the range of 2.1–3.7 and 1.4–7.8%, respectively. Further intra- and interday accuracy was within the range of 95.6–99.8 and 95.7–99.1% correspondingly. The mean recovery of ME and MED6 was 86.07 ± 6.87 and 80.31 ± 5.70%, respectively. The described method was successfully employed in bioequivalence study of ME in Indian male healthy human volunteers under fasting conditions. Hindawi Publishing Corporation 2012 2012-03-22 /pmc/articles/PMC3335321/ /pubmed/22567548 http://dx.doi.org/10.1155/2012/101249 Text en Copyright © 2012 Ravi Kumar Konda et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Konda, Ravi Kumar Challa, B. R. Chandu, Babu Rao Chandrasekhar, Kothapalli B. Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study |
title | Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study |
title_full | Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study |
title_fullStr | Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study |
title_full_unstemmed | Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study |
title_short | Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study |
title_sort | bioanalytical method development and validation of memantine in human plasma by high performance liquid chromatography with tandem mass spectrometry: application to bioequivalence study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3335321/ https://www.ncbi.nlm.nih.gov/pubmed/22567548 http://dx.doi.org/10.1155/2012/101249 |
work_keys_str_mv | AT kondaravikumar bioanalyticalmethoddevelopmentandvalidationofmemantineinhumanplasmabyhighperformanceliquidchromatographywithtandemmassspectrometryapplicationtobioequivalencestudy AT challabr bioanalyticalmethoddevelopmentandvalidationofmemantineinhumanplasmabyhighperformanceliquidchromatographywithtandemmassspectrometryapplicationtobioequivalencestudy AT chandubaburao bioanalyticalmethoddevelopmentandvalidationofmemantineinhumanplasmabyhighperformanceliquidchromatographywithtandemmassspectrometryapplicationtobioequivalencestudy AT chandrasekharkothapallib bioanalyticalmethoddevelopmentandvalidationofmemantineinhumanplasmabyhighperformanceliquidchromatographywithtandemmassspectrometryapplicationtobioequivalencestudy |