Cargando…

Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis

The goal of this paper is to access to pelvis position and morphology in standing posture and to determine the relative locations of their articular surfaces. This is obtained from coupling biplanar radiography and bone modeling. The technique involves different successive steps. Punctual landmarks...

Descripción completa

Detalles Bibliográficos
Autores principales: Berthonnaud, E., Hilmi, R., Dimnet, J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3337515/
https://www.ncbi.nlm.nih.gov/pubmed/22567279
http://dx.doi.org/10.1155/2012/685497
_version_ 1782231094427385856
author Berthonnaud, E.
Hilmi, R.
Dimnet, J.
author_facet Berthonnaud, E.
Hilmi, R.
Dimnet, J.
author_sort Berthonnaud, E.
collection PubMed
description The goal of this paper is to access to pelvis position and morphology in standing posture and to determine the relative locations of their articular surfaces. This is obtained from coupling biplanar radiography and bone modeling. The technique involves different successive steps. Punctual landmarks are first reconstructed, in space, from their projected images, identified on two orthogonal standing X-rays. Geometric models, of global pelvis and articular surfaces, are determined from punctual landmarks. The global pelvis is represented as a triangle of summits: the two femoral head centers and the sacral plateau center. The two acetabular cavities are modeled as hemispheres. The anterior sacral plateau edge is represented by an hemi-ellipsis. The modeled articular surfaces are projected on each X-ray. Their optimal location is obtained when the projected contours of their models best fit real outlines identified from landmark images. Linear and angular parameters characterizing the position of global pelvis and articular surfaces are calculated from the corresponding sets of axis. Relative positions of sacral plateau, and acetabular cavities, are then calculated. Two hundred standing pelvis, of subjects and scoliotic patients, have been studied. Examples are presented. They focus upon pelvis orientations, relative positions of articular surfaces, and pelvis asymmetries.
format Online
Article
Text
id pubmed-3337515
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33375152012-05-07 Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis Berthonnaud, E. Hilmi, R. Dimnet, J. Radiol Res Pract Research Article The goal of this paper is to access to pelvis position and morphology in standing posture and to determine the relative locations of their articular surfaces. This is obtained from coupling biplanar radiography and bone modeling. The technique involves different successive steps. Punctual landmarks are first reconstructed, in space, from their projected images, identified on two orthogonal standing X-rays. Geometric models, of global pelvis and articular surfaces, are determined from punctual landmarks. The global pelvis is represented as a triangle of summits: the two femoral head centers and the sacral plateau center. The two acetabular cavities are modeled as hemispheres. The anterior sacral plateau edge is represented by an hemi-ellipsis. The modeled articular surfaces are projected on each X-ray. Their optimal location is obtained when the projected contours of their models best fit real outlines identified from landmark images. Linear and angular parameters characterizing the position of global pelvis and articular surfaces are calculated from the corresponding sets of axis. Relative positions of sacral plateau, and acetabular cavities, are then calculated. Two hundred standing pelvis, of subjects and scoliotic patients, have been studied. Examples are presented. They focus upon pelvis orientations, relative positions of articular surfaces, and pelvis asymmetries. Hindawi Publishing Corporation 2012 2012-04-10 /pmc/articles/PMC3337515/ /pubmed/22567279 http://dx.doi.org/10.1155/2012/685497 Text en Copyright © 2012 E. Berthonnaud et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Berthonnaud, E.
Hilmi, R.
Dimnet, J.
Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis
title Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis
title_full Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis
title_fullStr Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis
title_full_unstemmed Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis
title_short Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis
title_sort accessing 3d location of standing pelvis: relative position of sacral plateau and acetabular cavities versus pelvis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3337515/
https://www.ncbi.nlm.nih.gov/pubmed/22567279
http://dx.doi.org/10.1155/2012/685497
work_keys_str_mv AT berthonnaude accessing3dlocationofstandingpelvisrelativepositionofsacralplateauandacetabularcavitiesversuspelvis
AT hilmir accessing3dlocationofstandingpelvisrelativepositionofsacralplateauandacetabularcavitiesversuspelvis
AT dimnetj accessing3dlocationofstandingpelvisrelativepositionofsacralplateauandacetabularcavitiesversuspelvis