Cargando…
A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System
BACKGROUND: For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N(2))MBW system. METHODS: The N(2)MBW s...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3338632/ https://www.ncbi.nlm.nih.gov/pubmed/22558338 http://dx.doi.org/10.1371/journal.pone.0036083 |
_version_ | 1782231230943592448 |
---|---|
author | Singer, Florian Houltz, Birgitta Latzin, Philipp Robinson, Paul Gustafsson, Per |
author_facet | Singer, Florian Houltz, Birgitta Latzin, Philipp Robinson, Paul Gustafsson, Per |
author_sort | Singer, Florian |
collection | PubMed |
description | BACKGROUND: For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N(2))MBW system. METHODS: The N(2)MBW setup indirectly measures the N(2) fraction (F(N2)) from main-stream carbon dioxide (CO(2)) and side-stream oxygen (O(2)) signals: F(N2) = 1−F(O2)−F(CO2)−F(Argon). For in vitro N(2)MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and F(CO2). In vivo N(2)MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N(2)MBW outcome was functional residual capacity (FRC). We assessed in vitro error (√[difference](2)) between measured and model FRC (100–4174 mL), and error between tests of in vivo FRC, lung clearance index (LCI), and normalized phase III slope indices (S(acin) and S(cond)). RESULTS: The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD) error was 2.3 (1.7)%. In 500 to 4174 mL FRCs, 121 (98%) of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2)%. LCI was the most reproducible ventilation inhomogeneity index. CONCLUSION: The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N(2)MBW system reliably measures lung volumes and delivers reproducible LCI values. |
format | Online Article Text |
id | pubmed-3338632 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-33386322012-05-03 A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System Singer, Florian Houltz, Birgitta Latzin, Philipp Robinson, Paul Gustafsson, Per PLoS One Research Article BACKGROUND: For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N(2))MBW system. METHODS: The N(2)MBW setup indirectly measures the N(2) fraction (F(N2)) from main-stream carbon dioxide (CO(2)) and side-stream oxygen (O(2)) signals: F(N2) = 1−F(O2)−F(CO2)−F(Argon). For in vitro N(2)MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and F(CO2). In vivo N(2)MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N(2)MBW outcome was functional residual capacity (FRC). We assessed in vitro error (√[difference](2)) between measured and model FRC (100–4174 mL), and error between tests of in vivo FRC, lung clearance index (LCI), and normalized phase III slope indices (S(acin) and S(cond)). RESULTS: The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD) error was 2.3 (1.7)%. In 500 to 4174 mL FRCs, 121 (98%) of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2)%. LCI was the most reproducible ventilation inhomogeneity index. CONCLUSION: The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N(2)MBW system reliably measures lung volumes and delivers reproducible LCI values. Public Library of Science 2012-04-27 /pmc/articles/PMC3338632/ /pubmed/22558338 http://dx.doi.org/10.1371/journal.pone.0036083 Text en Singer et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Singer, Florian Houltz, Birgitta Latzin, Philipp Robinson, Paul Gustafsson, Per A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System |
title | A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System |
title_full | A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System |
title_fullStr | A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System |
title_full_unstemmed | A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System |
title_short | A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System |
title_sort | realistic validation study of a new nitrogen multiple-breath washout system |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3338632/ https://www.ncbi.nlm.nih.gov/pubmed/22558338 http://dx.doi.org/10.1371/journal.pone.0036083 |
work_keys_str_mv | AT singerflorian arealisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT houltzbirgitta arealisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT latzinphilipp arealisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT robinsonpaul arealisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT gustafssonper arealisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT singerflorian realisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT houltzbirgitta realisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT latzinphilipp realisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT robinsonpaul realisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem AT gustafssonper realisticvalidationstudyofanewnitrogenmultiplebreathwashoutsystem |