Cargando…

Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome

BACKGROUND: We developed a single-color multitarget flow cytometry (SM-FC) assay, a single-tube assay with graded mean fluorescence intensities (MFIs). We evaluated the repeatability of SM-FC, and its correlation with multicolor flow cytometry (MFC), to assess its application as a routine FC assay....

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Joonhong, Han, Kyungja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3339295/
https://www.ncbi.nlm.nih.gov/pubmed/22563550
http://dx.doi.org/10.3343/alm.2012.32.3.171
_version_ 1782231331525099520
author Park, Joonhong
Han, Kyungja
author_facet Park, Joonhong
Han, Kyungja
author_sort Park, Joonhong
collection PubMed
description BACKGROUND: We developed a single-color multitarget flow cytometry (SM-FC) assay, a single-tube assay with graded mean fluorescence intensities (MFIs). We evaluated the repeatability of SM-FC, and its correlation with multicolor flow cytometry (MFC), to assess its application as a routine FC assay. METHODS: We selected CD19, CD3, CD4, and CD8 as antigen targets to analyze a lymphocyte subset. MFIs were graded by adjusting monoclonal antibody (mAb) volumes to detect several cell populations. Dimly labeled mAb was prepared by decreasing mAb volume and the optimum diluted volume was determined by serial dilution. SM-FC repeatability was analyzed 10 times in 2 normal controls. The correlation between SM-FC and MFC was evaluated in 20 normal and 23 patient samples. RESULTS: CV values (0.8-5.0% and 1.3-4.1% in samples 1 and 2, respectively) acquired by SM-FC with CD3-fluorescein α-isothyocyanate (FITC)(dim)+CD4-FITC(bright) and with CD19-FITC(dim)+CD3-FITC(bright) showed good repeatability, comparable to that acquired by MFC (1.6-3.7% and 1.0-4.8% in samples 1 and 2, respectively). Excellent correlation was observed between the 2 methods in the 20 normal samples (B cells, T cells, non-T(helper) cells, and T(helper) cells; r(2)=0.87, 0.97, 0.97, and 0.98, respectively; P<0.05). There were also linear relationships between SM-FC with CD19-FITC(dim)+CD3-FITC(bright) and CD8-PE(dim)+CD4-PE(bright), and MFC, in the 23 patient samples (B cells, T cells, T(cytotoxic) cells, and T(helper) cells; r(2)≥0.98, 0.99, 0.99, and 0.99, respectively; P<0.05). CONCLUSIONS: The multicolor, single-tube SM-FC technique is a potential alternative tool for identifying a lymphocyte subset.
format Online
Article
Text
id pubmed-3339295
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-33392952012-05-05 Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome Park, Joonhong Han, Kyungja Ann Lab Med Original Article BACKGROUND: We developed a single-color multitarget flow cytometry (SM-FC) assay, a single-tube assay with graded mean fluorescence intensities (MFIs). We evaluated the repeatability of SM-FC, and its correlation with multicolor flow cytometry (MFC), to assess its application as a routine FC assay. METHODS: We selected CD19, CD3, CD4, and CD8 as antigen targets to analyze a lymphocyte subset. MFIs were graded by adjusting monoclonal antibody (mAb) volumes to detect several cell populations. Dimly labeled mAb was prepared by decreasing mAb volume and the optimum diluted volume was determined by serial dilution. SM-FC repeatability was analyzed 10 times in 2 normal controls. The correlation between SM-FC and MFC was evaluated in 20 normal and 23 patient samples. RESULTS: CV values (0.8-5.0% and 1.3-4.1% in samples 1 and 2, respectively) acquired by SM-FC with CD3-fluorescein α-isothyocyanate (FITC)(dim)+CD4-FITC(bright) and with CD19-FITC(dim)+CD3-FITC(bright) showed good repeatability, comparable to that acquired by MFC (1.6-3.7% and 1.0-4.8% in samples 1 and 2, respectively). Excellent correlation was observed between the 2 methods in the 20 normal samples (B cells, T cells, non-T(helper) cells, and T(helper) cells; r(2)=0.87, 0.97, 0.97, and 0.98, respectively; P<0.05). There were also linear relationships between SM-FC with CD19-FITC(dim)+CD3-FITC(bright) and CD8-PE(dim)+CD4-PE(bright), and MFC, in the 23 patient samples (B cells, T cells, T(cytotoxic) cells, and T(helper) cells; r(2)≥0.98, 0.99, 0.99, and 0.99, respectively; P<0.05). CONCLUSIONS: The multicolor, single-tube SM-FC technique is a potential alternative tool for identifying a lymphocyte subset. The Korean Society for Laboratory Medicine 2012-05 2012-04-18 /pmc/articles/PMC3339295/ /pubmed/22563550 http://dx.doi.org/10.3343/alm.2012.32.3.171 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Park, Joonhong
Han, Kyungja
Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome
title Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome
title_full Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome
title_fullStr Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome
title_full_unstemmed Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome
title_short Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome
title_sort single-color multitarget flow cytometry using monoclonal antibodies labeled with different intensities of the same fluorochrome
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3339295/
https://www.ncbi.nlm.nih.gov/pubmed/22563550
http://dx.doi.org/10.3343/alm.2012.32.3.171
work_keys_str_mv AT parkjoonhong singlecolormultitargetflowcytometryusingmonoclonalantibodieslabeledwithdifferentintensitiesofthesamefluorochrome
AT hankyungja singlecolormultitargetflowcytometryusingmonoclonalantibodieslabeledwithdifferentintensitiesofthesamefluorochrome