Cargando…
Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome
BACKGROUND: We developed a single-color multitarget flow cytometry (SM-FC) assay, a single-tube assay with graded mean fluorescence intensities (MFIs). We evaluated the repeatability of SM-FC, and its correlation with multicolor flow cytometry (MFC), to assess its application as a routine FC assay....
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3339295/ https://www.ncbi.nlm.nih.gov/pubmed/22563550 http://dx.doi.org/10.3343/alm.2012.32.3.171 |
_version_ | 1782231331525099520 |
---|---|
author | Park, Joonhong Han, Kyungja |
author_facet | Park, Joonhong Han, Kyungja |
author_sort | Park, Joonhong |
collection | PubMed |
description | BACKGROUND: We developed a single-color multitarget flow cytometry (SM-FC) assay, a single-tube assay with graded mean fluorescence intensities (MFIs). We evaluated the repeatability of SM-FC, and its correlation with multicolor flow cytometry (MFC), to assess its application as a routine FC assay. METHODS: We selected CD19, CD3, CD4, and CD8 as antigen targets to analyze a lymphocyte subset. MFIs were graded by adjusting monoclonal antibody (mAb) volumes to detect several cell populations. Dimly labeled mAb was prepared by decreasing mAb volume and the optimum diluted volume was determined by serial dilution. SM-FC repeatability was analyzed 10 times in 2 normal controls. The correlation between SM-FC and MFC was evaluated in 20 normal and 23 patient samples. RESULTS: CV values (0.8-5.0% and 1.3-4.1% in samples 1 and 2, respectively) acquired by SM-FC with CD3-fluorescein α-isothyocyanate (FITC)(dim)+CD4-FITC(bright) and with CD19-FITC(dim)+CD3-FITC(bright) showed good repeatability, comparable to that acquired by MFC (1.6-3.7% and 1.0-4.8% in samples 1 and 2, respectively). Excellent correlation was observed between the 2 methods in the 20 normal samples (B cells, T cells, non-T(helper) cells, and T(helper) cells; r(2)=0.87, 0.97, 0.97, and 0.98, respectively; P<0.05). There were also linear relationships between SM-FC with CD19-FITC(dim)+CD3-FITC(bright) and CD8-PE(dim)+CD4-PE(bright), and MFC, in the 23 patient samples (B cells, T cells, T(cytotoxic) cells, and T(helper) cells; r(2)≥0.98, 0.99, 0.99, and 0.99, respectively; P<0.05). CONCLUSIONS: The multicolor, single-tube SM-FC technique is a potential alternative tool for identifying a lymphocyte subset. |
format | Online Article Text |
id | pubmed-3339295 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-33392952012-05-05 Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome Park, Joonhong Han, Kyungja Ann Lab Med Original Article BACKGROUND: We developed a single-color multitarget flow cytometry (SM-FC) assay, a single-tube assay with graded mean fluorescence intensities (MFIs). We evaluated the repeatability of SM-FC, and its correlation with multicolor flow cytometry (MFC), to assess its application as a routine FC assay. METHODS: We selected CD19, CD3, CD4, and CD8 as antigen targets to analyze a lymphocyte subset. MFIs were graded by adjusting monoclonal antibody (mAb) volumes to detect several cell populations. Dimly labeled mAb was prepared by decreasing mAb volume and the optimum diluted volume was determined by serial dilution. SM-FC repeatability was analyzed 10 times in 2 normal controls. The correlation between SM-FC and MFC was evaluated in 20 normal and 23 patient samples. RESULTS: CV values (0.8-5.0% and 1.3-4.1% in samples 1 and 2, respectively) acquired by SM-FC with CD3-fluorescein α-isothyocyanate (FITC)(dim)+CD4-FITC(bright) and with CD19-FITC(dim)+CD3-FITC(bright) showed good repeatability, comparable to that acquired by MFC (1.6-3.7% and 1.0-4.8% in samples 1 and 2, respectively). Excellent correlation was observed between the 2 methods in the 20 normal samples (B cells, T cells, non-T(helper) cells, and T(helper) cells; r(2)=0.87, 0.97, 0.97, and 0.98, respectively; P<0.05). There were also linear relationships between SM-FC with CD19-FITC(dim)+CD3-FITC(bright) and CD8-PE(dim)+CD4-PE(bright), and MFC, in the 23 patient samples (B cells, T cells, T(cytotoxic) cells, and T(helper) cells; r(2)≥0.98, 0.99, 0.99, and 0.99, respectively; P<0.05). CONCLUSIONS: The multicolor, single-tube SM-FC technique is a potential alternative tool for identifying a lymphocyte subset. The Korean Society for Laboratory Medicine 2012-05 2012-04-18 /pmc/articles/PMC3339295/ /pubmed/22563550 http://dx.doi.org/10.3343/alm.2012.32.3.171 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Park, Joonhong Han, Kyungja Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome |
title | Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome |
title_full | Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome |
title_fullStr | Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome |
title_full_unstemmed | Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome |
title_short | Single-color Multitarget Flow Cytometry Using Monoclonal Antibodies Labeled with Different Intensities of the Same Fluorochrome |
title_sort | single-color multitarget flow cytometry using monoclonal antibodies labeled with different intensities of the same fluorochrome |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3339295/ https://www.ncbi.nlm.nih.gov/pubmed/22563550 http://dx.doi.org/10.3343/alm.2012.32.3.171 |
work_keys_str_mv | AT parkjoonhong singlecolormultitargetflowcytometryusingmonoclonalantibodieslabeledwithdifferentintensitiesofthesamefluorochrome AT hankyungja singlecolormultitargetflowcytometryusingmonoclonalantibodieslabeledwithdifferentintensitiesofthesamefluorochrome |