Soft Tissue Attenuation Patterns Associated with Supine Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study

PURPOSE: Soft-tissue attenuation patterns in SPECT-myocardial perfusion imaging (MPI) of supine acquisition systems are well recognized. Their prevalence and interaction with body-habitus and gender are ill-defined, which we sought to describe in this study. METHODS: In a cross-sectional study, we d...

Descripción completa

Detalles Bibliográficos
Autores principales: Doukky, Rami, Rahaby, Mouyyad, Alyousef, Tareq, Vashistha, Raj, Chawla, Dave, Amin, Amit P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3339431/
https://www.ncbi.nlm.nih.gov/pubmed/22550547
http://dx.doi.org/10.2174/1874192401206010033
_version_ 1782231356522102784
author Doukky, Rami
Rahaby, Mouyyad
Alyousef, Tareq
Vashistha, Raj
Chawla, Dave
Amin, Amit P
author_facet Doukky, Rami
Rahaby, Mouyyad
Alyousef, Tareq
Vashistha, Raj
Chawla, Dave
Amin, Amit P
author_sort Doukky, Rami
collection PubMed
description PURPOSE: Soft-tissue attenuation patterns in SPECT-myocardial perfusion imaging (MPI) of supine acquisition systems are well recognized. Their prevalence and interaction with body-habitus and gender are ill-defined, which we sought to describe in this study. METHODS: In a cross-sectional study, we described the prevalence of soft-tissue attenuation patterns in normal SPECT-MPI studies acquired with a supine patient-position SPECT system. RESULTS: In 263 normal, clinically-indicated, supine-acquisition SPECT-MPIs the attenuation patterns observed were: anterior (35.4%), inferior (41.8%) and lateral (13.3%). Anterior attenuation was more prevalent among women (50.7% vs. 15.7%, P<0.001) and was associated with chest circumference among men. Conversely, inferior attenuation was more prevalent among men (78.3% vs. 13.5%, P<0.001) and was not affected by body-habitus. Lateral attenuation was more common among women (19.6% vs. 5.2%, p=0.001) and was associated with obesity (p=0.015). CONCLUSIONS: Soft-tissue attenuation artifacts are common in supine-acquisition SPECT-MPI. The recognition of their prevalence and association with body-habitus and gender is critical for the accurate interpretation of SPECT-MPI.
format Online
Article
Text
id pubmed-3339431
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-33394312012-05-01 Soft Tissue Attenuation Patterns Associated with Supine Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study Doukky, Rami Rahaby, Mouyyad Alyousef, Tareq Vashistha, Raj Chawla, Dave Amin, Amit P Open Cardiovasc Med J Article PURPOSE: Soft-tissue attenuation patterns in SPECT-myocardial perfusion imaging (MPI) of supine acquisition systems are well recognized. Their prevalence and interaction with body-habitus and gender are ill-defined, which we sought to describe in this study. METHODS: In a cross-sectional study, we described the prevalence of soft-tissue attenuation patterns in normal SPECT-MPI studies acquired with a supine patient-position SPECT system. RESULTS: In 263 normal, clinically-indicated, supine-acquisition SPECT-MPIs the attenuation patterns observed were: anterior (35.4%), inferior (41.8%) and lateral (13.3%). Anterior attenuation was more prevalent among women (50.7% vs. 15.7%, P<0.001) and was associated with chest circumference among men. Conversely, inferior attenuation was more prevalent among men (78.3% vs. 13.5%, P<0.001) and was not affected by body-habitus. Lateral attenuation was more common among women (19.6% vs. 5.2%, p=0.001) and was associated with obesity (p=0.015). CONCLUSIONS: Soft-tissue attenuation artifacts are common in supine-acquisition SPECT-MPI. The recognition of their prevalence and association with body-habitus and gender is critical for the accurate interpretation of SPECT-MPI. Bentham Open 2012-04-17 /pmc/articles/PMC3339431/ /pubmed/22550547 http://dx.doi.org/10.2174/1874192401206010033 Text en © Doukky et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Doukky, Rami
Rahaby, Mouyyad
Alyousef, Tareq
Vashistha, Raj
Chawla, Dave
Amin, Amit P
Soft Tissue Attenuation Patterns Associated with Supine Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study
title Soft Tissue Attenuation Patterns Associated with Supine Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study
title_full Soft Tissue Attenuation Patterns Associated with Supine Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study
title_fullStr Soft Tissue Attenuation Patterns Associated with Supine Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study
title_full_unstemmed Soft Tissue Attenuation Patterns Associated with Supine Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study
title_short Soft Tissue Attenuation Patterns Associated with Supine Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study
title_sort soft tissue attenuation patterns associated with supine acquisition spect myocardial perfusion imaging: a descriptive study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3339431/
https://www.ncbi.nlm.nih.gov/pubmed/22550547
http://dx.doi.org/10.2174/1874192401206010033
work_keys_str_mv AT doukkyrami softtissueattenuationpatternsassociatedwithsupineacquisitionspectmyocardialperfusionimagingadescriptivestudy
AT rahabymouyyad softtissueattenuationpatternsassociatedwithsupineacquisitionspectmyocardialperfusionimagingadescriptivestudy
AT alyouseftareq softtissueattenuationpatternsassociatedwithsupineacquisitionspectmyocardialperfusionimagingadescriptivestudy
AT vashistharaj softtissueattenuationpatternsassociatedwithsupineacquisitionspectmyocardialperfusionimagingadescriptivestudy
AT chawladave softtissueattenuationpatternsassociatedwithsupineacquisitionspectmyocardialperfusionimagingadescriptivestudy
AT aminamitp softtissueattenuationpatternsassociatedwithsupineacquisitionspectmyocardialperfusionimagingadescriptivestudy