Toxicity of topical lidocaine applied to the breasts to reduce discomfort during screening mammography

BACKGROUND: We measured the effect of 30 milliliters (mL) of 4% lidocaine gel on the breasts and chest wall of healthy women covered for 1 h on plasma concentrations of lidocaine and its principal metabolite, monoethylglycinexylidide (MEGX), electrocardiogram (EKG) results, and adverse events. MATER...

Descripción completa

Detalles Bibliográficos
Autores principales: Lambertz, Colleen K, Johnson, Christopher J, Montgomery, Paul G, Maxwell, James R, Fry, Stefanie J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3339725/
https://www.ncbi.nlm.nih.gov/pubmed/22557743
http://dx.doi.org/10.4103/0970-9185.94859
Descripción
Sumario:BACKGROUND: We measured the effect of 30 milliliters (mL) of 4% lidocaine gel on the breasts and chest wall of healthy women covered for 1 h on plasma concentrations of lidocaine and its principal metabolite, monoethylglycinexylidide (MEGX), electrocardiogram (EKG) results, and adverse events. MATERIALS AND METHODS: This institutional review board-approved, prospective, open-label study complied with the Health Insurance Portability and Accountability Act (HIPAA). The study evaluated 10 healthy women aged 42-75 years with 30 mL of 4% lidocaine gel on the skin of the breasts and chest wall covered for 1 h. Cardiac and neurological assessments were performed and blood was drawn for lidocaine and MEGX levels at baseline and 1/2, 1, 2, 3, 4, 6, and 8 h after application. EKGs were performed before application and at 3 h. Subjects provided informed written consent. Primary and secondary outcomes were plasma concentrations of lidocaine and MEGX and frequency of adverse events, respectively. Statistical analysis included paired t-tests for EKGs and repeated measures regression for vital signs. RESULTS: No lidocaine was detected in the blood of 9 of 10 subjects. One subject had low plasma concentrations of lidocaine just above the level of detection the first 4 h after application only. No MEGX was detected. Mean decrease in heart rate was likely multifactorial. CONCLUSION: Thirty mL of 4% lidocaine gel on the breasts and chest wall covered for 1 h in healthy women resulted in plasma concentrations of lidocaine and MEGX well below therapeutic or toxic levels and no clinically significant adverse events.