Cell phone based balance trainer

BACKGROUND: In their current laboratory-based form, existing vibrotactile sensory augmentation technologies that provide cues of body motion are impractical for home-based rehabilitation use due to their size, weight, complexity, calibration procedures, cost, and fragility. METHODS: We have designed...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Beom-Chan, Kim, Jeonghee, Chen, Shu, Sienko, Kathleen H
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3340298/
https://www.ncbi.nlm.nih.gov/pubmed/22316167
http://dx.doi.org/10.1186/1743-0003-9-10
_version_ 1782231442070175744
author Lee, Beom-Chan
Kim, Jeonghee
Chen, Shu
Sienko, Kathleen H
author_facet Lee, Beom-Chan
Kim, Jeonghee
Chen, Shu
Sienko, Kathleen H
author_sort Lee, Beom-Chan
collection PubMed
description BACKGROUND: In their current laboratory-based form, existing vibrotactile sensory augmentation technologies that provide cues of body motion are impractical for home-based rehabilitation use due to their size, weight, complexity, calibration procedures, cost, and fragility. METHODS: We have designed and developed a cell phone based vibrotactile feedback system for potential use in balance rehabilitation training in clinical and home environments. It comprises an iPhone with an embedded tri-axial linear accelerometer, custom software to estimate body tilt, a "tactor bud" accessory that plugs into the headphone jack to provide vibrotactile cues of body tilt, and a battery. Five young healthy subjects (24 ± 2.8 yrs, 3 females and 2 males) and four subjects with vestibular deficits (42.25 ± 13.5 yrs, 2 females and 2 males) participated in a proof-of-concept study to evaluate the effectiveness of the system. Healthy subjects used the system with eyes closed during Romberg, semi-tandem Romberg, and tandem Romberg stances. Subjects with vestibular deficits used the system with both eyes-open and eyes-closed conditions during semi-tandem Romberg stance. Vibrotactile feedback was provided when the subject exceeded either an anterior-posterior (A/P) or a medial-lateral (M/L) body tilt threshold. Subjects were instructed to move away from the vibration. RESULTS: The system was capable of providing real-time vibrotactile cues that informed corrective postural responses. When feedback was available, both healthy subjects and those with vestibular deficits significantly reduced their A/P or M/L RMS sway (depending on the direction of feedback), had significantly smaller elliptical area fits to their sway trajectory, spent a significantly greater mean percentage time within the no feedback zone, and showed a significantly greater A/P or M/L mean power frequency. CONCLUSION: The results suggest that the real-time feedback provided by this system can be used to reduce body sway. Its advantages over more complex laboratory-based and commercial balance training systems in terms of cost, size, weight, functionality, flexibility, and accessibility make it a good candidate for further home-based balance training evaluation.
format Online
Article
Text
id pubmed-3340298
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33402982012-05-01 Cell phone based balance trainer Lee, Beom-Chan Kim, Jeonghee Chen, Shu Sienko, Kathleen H J Neuroeng Rehabil Research BACKGROUND: In their current laboratory-based form, existing vibrotactile sensory augmentation technologies that provide cues of body motion are impractical for home-based rehabilitation use due to their size, weight, complexity, calibration procedures, cost, and fragility. METHODS: We have designed and developed a cell phone based vibrotactile feedback system for potential use in balance rehabilitation training in clinical and home environments. It comprises an iPhone with an embedded tri-axial linear accelerometer, custom software to estimate body tilt, a "tactor bud" accessory that plugs into the headphone jack to provide vibrotactile cues of body tilt, and a battery. Five young healthy subjects (24 ± 2.8 yrs, 3 females and 2 males) and four subjects with vestibular deficits (42.25 ± 13.5 yrs, 2 females and 2 males) participated in a proof-of-concept study to evaluate the effectiveness of the system. Healthy subjects used the system with eyes closed during Romberg, semi-tandem Romberg, and tandem Romberg stances. Subjects with vestibular deficits used the system with both eyes-open and eyes-closed conditions during semi-tandem Romberg stance. Vibrotactile feedback was provided when the subject exceeded either an anterior-posterior (A/P) or a medial-lateral (M/L) body tilt threshold. Subjects were instructed to move away from the vibration. RESULTS: The system was capable of providing real-time vibrotactile cues that informed corrective postural responses. When feedback was available, both healthy subjects and those with vestibular deficits significantly reduced their A/P or M/L RMS sway (depending on the direction of feedback), had significantly smaller elliptical area fits to their sway trajectory, spent a significantly greater mean percentage time within the no feedback zone, and showed a significantly greater A/P or M/L mean power frequency. CONCLUSION: The results suggest that the real-time feedback provided by this system can be used to reduce body sway. Its advantages over more complex laboratory-based and commercial balance training systems in terms of cost, size, weight, functionality, flexibility, and accessibility make it a good candidate for further home-based balance training evaluation. BioMed Central 2012-02-08 /pmc/articles/PMC3340298/ /pubmed/22316167 http://dx.doi.org/10.1186/1743-0003-9-10 Text en Copyright ©2012 Lee et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Lee, Beom-Chan
Kim, Jeonghee
Chen, Shu
Sienko, Kathleen H
Cell phone based balance trainer
title Cell phone based balance trainer
title_full Cell phone based balance trainer
title_fullStr Cell phone based balance trainer
title_full_unstemmed Cell phone based balance trainer
title_short Cell phone based balance trainer
title_sort cell phone based balance trainer
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3340298/
https://www.ncbi.nlm.nih.gov/pubmed/22316167
http://dx.doi.org/10.1186/1743-0003-9-10
work_keys_str_mv AT leebeomchan cellphonebasedbalancetrainer
AT kimjeonghee cellphonebasedbalancetrainer
AT chenshu cellphonebasedbalancetrainer
AT sienkokathleenh cellphonebasedbalancetrainer