Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation

BACKGROUND: Methods for the electrical inhibition of cardiac excitation have long been sought to control excitability and conduction, but to date remain largely impractical. High-amplitude alternating current (AC) stimulation has been known to extend cardiac action potentials (APs), and has been rec...

Descripción completa

Detalles Bibliográficos
Autores principales: Dura, Burak, Kovacs, Gregory T. A., Giovangrandi, Laurent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3340354/
https://www.ncbi.nlm.nih.gov/pubmed/22558389
http://dx.doi.org/10.1371/journal.pone.0036217
_version_ 1782231454371020800
author Dura, Burak
Kovacs, Gregory T. A.
Giovangrandi, Laurent
author_facet Dura, Burak
Kovacs, Gregory T. A.
Giovangrandi, Laurent
author_sort Dura, Burak
collection PubMed
description BACKGROUND: Methods for the electrical inhibition of cardiac excitation have long been sought to control excitability and conduction, but to date remain largely impractical. High-amplitude alternating current (AC) stimulation has been known to extend cardiac action potentials (APs), and has been recently exploited to terminate reentrant arrhythmias by producing reversible conduction blocks. Yet, low-amplitude currents at similar frequencies have been shown to entrain cardiac tissues by generation of repetitive APs, leading in some cases to ventricular fibrillation and hemodynamic collapse in vivo. Therefore, an inhibition method that does not lead to entrainment – irrespective of the stimulation amplitude (bound to fluctuate in an in vivo setting) – is highly desirable. METHODOLOGY/PRINCIPAL FINDINGS: We investigated the effects of broader amplitude and frequency ranges on the inhibitory effects of extracellular AC stimulation on HL-1 cardiomyocytes cultured on microelectrode arrays, using both sinusoidal and square waveforms. Our results indicate that, at sufficiently high frequencies, cardiac tissue exhibits a binary response to stimulus amplitude with either prolonged APs or no effect, thereby effectively avoiding the risks of entrainment by repetitive firing observed at lower frequencies. We further demonstrate the ability to precisely define reversible local conduction blocks in beating cultures without influencing the propagation activity in non-blocked areas. The conduction blocks were spatiotemporally controlled by electrode geometry and stimuli duration, respectively, and sustainable for long durations (300 s). CONCLUSION/SIGNIFICANCE: Inhibition of cardiac excitation induced by high-frequency AC stimulation exhibits a binary response to amplitude above a threshold frequency, enabling the generation of reversible conduction blocks without the risks of entrainment. This inhibition method could yield novel approaches for arrhythmia modeling in vitro, as well as safer and more efficacious tools for in vivo cardiac mapping and radio-frequency ablation guidance applications.
format Online
Article
Text
id pubmed-3340354
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-33403542012-05-03 Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation Dura, Burak Kovacs, Gregory T. A. Giovangrandi, Laurent PLoS One Research Article BACKGROUND: Methods for the electrical inhibition of cardiac excitation have long been sought to control excitability and conduction, but to date remain largely impractical. High-amplitude alternating current (AC) stimulation has been known to extend cardiac action potentials (APs), and has been recently exploited to terminate reentrant arrhythmias by producing reversible conduction blocks. Yet, low-amplitude currents at similar frequencies have been shown to entrain cardiac tissues by generation of repetitive APs, leading in some cases to ventricular fibrillation and hemodynamic collapse in vivo. Therefore, an inhibition method that does not lead to entrainment – irrespective of the stimulation amplitude (bound to fluctuate in an in vivo setting) – is highly desirable. METHODOLOGY/PRINCIPAL FINDINGS: We investigated the effects of broader amplitude and frequency ranges on the inhibitory effects of extracellular AC stimulation on HL-1 cardiomyocytes cultured on microelectrode arrays, using both sinusoidal and square waveforms. Our results indicate that, at sufficiently high frequencies, cardiac tissue exhibits a binary response to stimulus amplitude with either prolonged APs or no effect, thereby effectively avoiding the risks of entrainment by repetitive firing observed at lower frequencies. We further demonstrate the ability to precisely define reversible local conduction blocks in beating cultures without influencing the propagation activity in non-blocked areas. The conduction blocks were spatiotemporally controlled by electrode geometry and stimuli duration, respectively, and sustainable for long durations (300 s). CONCLUSION/SIGNIFICANCE: Inhibition of cardiac excitation induced by high-frequency AC stimulation exhibits a binary response to amplitude above a threshold frequency, enabling the generation of reversible conduction blocks without the risks of entrainment. This inhibition method could yield novel approaches for arrhythmia modeling in vitro, as well as safer and more efficacious tools for in vivo cardiac mapping and radio-frequency ablation guidance applications. Public Library of Science 2012-04-30 /pmc/articles/PMC3340354/ /pubmed/22558389 http://dx.doi.org/10.1371/journal.pone.0036217 Text en Dura et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Dura, Burak
Kovacs, Gregory T. A.
Giovangrandi, Laurent
Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation
title Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation
title_full Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation
title_fullStr Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation
title_full_unstemmed Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation
title_short Spatiotemporally Controlled Cardiac Conduction Block Using High-Frequency Electrical Stimulation
title_sort spatiotemporally controlled cardiac conduction block using high-frequency electrical stimulation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3340354/
https://www.ncbi.nlm.nih.gov/pubmed/22558389
http://dx.doi.org/10.1371/journal.pone.0036217
work_keys_str_mv AT duraburak spatiotemporallycontrolledcardiacconductionblockusinghighfrequencyelectricalstimulation
AT kovacsgregoryta spatiotemporallycontrolledcardiacconductionblockusinghighfrequencyelectricalstimulation
AT giovangrandilaurent spatiotemporallycontrolledcardiacconductionblockusinghighfrequencyelectricalstimulation