Cargando…

Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification

BACKGROUND: The identification of differences in protein expression resulting from methodical variations is an essential component to the interpretation of true, biologically significant results. AIMS: We used the Lowry and Bradford methods- two most commonly used methods for protein quantification,...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Tzong-Shi, Yiao, Szu-Yu, Lim, Kenneth, Jensen, Roderick V., Hsiao, Li-Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3341640/
https://www.ncbi.nlm.nih.gov/pubmed/22558582
http://dx.doi.org/10.4297/najms.2010.2325
_version_ 1782231569020223488
author Lu, Tzong-Shi
Yiao, Szu-Yu
Lim, Kenneth
Jensen, Roderick V.
Hsiao, Li-Li
author_facet Lu, Tzong-Shi
Yiao, Szu-Yu
Lim, Kenneth
Jensen, Roderick V.
Hsiao, Li-Li
author_sort Lu, Tzong-Shi
collection PubMed
description BACKGROUND: The identification of differences in protein expression resulting from methodical variations is an essential component to the interpretation of true, biologically significant results. AIMS: We used the Lowry and Bradford methods- two most commonly used methods for protein quantification, to assess whether differential protein expressions are a result of true biological or methodical variations. MATERIAL & METHODS: Differential protein expression patterns was assessed by western blot following protein quantification by the Lowry and Bradford methods. RESULTS: We have observed significant variations in protein concentrations following assessment with the Lowry versus Bradford methods, using identical samples. Greater variations in protein concentration readings were observed over time and in samples with higher concentrations, with the Bradford method. Identical samples quantified using both methods yielded significantly different expression patterns on Western blot. CONCLUSIONS: We show for the first time that methodical variations observed in these protein assay techniques, can potentially translate into differential protein expression patterns, that can be falsely taken to be biologically significant. Our study therefore highlights the pivotal need to carefully consider methodical approaches to protein quantification in techniques that report quantitative differences.
format Online
Article
Text
id pubmed-3341640
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-33416402012-05-03 Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification Lu, Tzong-Shi Yiao, Szu-Yu Lim, Kenneth Jensen, Roderick V. Hsiao, Li-Li N Am J Med Sci Technical Article BACKGROUND: The identification of differences in protein expression resulting from methodical variations is an essential component to the interpretation of true, biologically significant results. AIMS: We used the Lowry and Bradford methods- two most commonly used methods for protein quantification, to assess whether differential protein expressions are a result of true biological or methodical variations. MATERIAL & METHODS: Differential protein expression patterns was assessed by western blot following protein quantification by the Lowry and Bradford methods. RESULTS: We have observed significant variations in protein concentrations following assessment with the Lowry versus Bradford methods, using identical samples. Greater variations in protein concentration readings were observed over time and in samples with higher concentrations, with the Bradford method. Identical samples quantified using both methods yielded significantly different expression patterns on Western blot. CONCLUSIONS: We show for the first time that methodical variations observed in these protein assay techniques, can potentially translate into differential protein expression patterns, that can be falsely taken to be biologically significant. Our study therefore highlights the pivotal need to carefully consider methodical approaches to protein quantification in techniques that report quantitative differences. Medknow Publications & Media Pvt Ltd 2010-07 /pmc/articles/PMC3341640/ /pubmed/22558582 http://dx.doi.org/10.4297/najms.2010.2325 Text en Copyright: © North American Journal of Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Article
Lu, Tzong-Shi
Yiao, Szu-Yu
Lim, Kenneth
Jensen, Roderick V.
Hsiao, Li-Li
Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification
title Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification
title_full Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification
title_fullStr Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification
title_full_unstemmed Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification
title_short Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification
title_sort interpretation of biological and mechanical variations between the lowry versus bradford method for protein quantification
topic Technical Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3341640/
https://www.ncbi.nlm.nih.gov/pubmed/22558582
http://dx.doi.org/10.4297/najms.2010.2325
work_keys_str_mv AT lutzongshi interpretationofbiologicalandmechanicalvariationsbetweenthelowryversusbradfordmethodforproteinquantification
AT yiaoszuyu interpretationofbiologicalandmechanicalvariationsbetweenthelowryversusbradfordmethodforproteinquantification
AT limkenneth interpretationofbiologicalandmechanicalvariationsbetweenthelowryversusbradfordmethodforproteinquantification
AT jensenroderickv interpretationofbiologicalandmechanicalvariationsbetweenthelowryversusbradfordmethodforproteinquantification
AT hsiaolili interpretationofbiologicalandmechanicalvariationsbetweenthelowryversusbradfordmethodforproteinquantification