Cargando…

Development of an Electrogenerated Chemiluminescence Biosensor using Carboxylic acid-functionalized MWCNT and Au Nanoparticles

A COOH-F-MWCNT-Nafion-Ru(bpy)(3)(2+)-Au-ADH electrogenerated chemiluminescence (ECL) electrode using COOH-functionalized MWCNT (COOH-F-MWCNT) and Au nanoparticles synthesized by the radiation method was fabricated for ethanol sensing. A higher sensing efficiency for ethanol for the ECL biosensor pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Piao, Ming-Hua, Yang, Dae-Soo, Yoon, Kuk-Ro, Lee, Seung-Ho, Choi, Seong-Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3345825/
https://www.ncbi.nlm.nih.gov/pubmed/22573979
http://dx.doi.org/10.3390/s90301662
_version_ 1782232160680280064
author Piao, Ming-Hua
Yang, Dae-Soo
Yoon, Kuk-Ro
Lee, Seung-Ho
Choi, Seong-Ho
author_facet Piao, Ming-Hua
Yang, Dae-Soo
Yoon, Kuk-Ro
Lee, Seung-Ho
Choi, Seong-Ho
author_sort Piao, Ming-Hua
collection PubMed
description A COOH-F-MWCNT-Nafion-Ru(bpy)(3)(2+)-Au-ADH electrogenerated chemiluminescence (ECL) electrode using COOH-functionalized MWCNT (COOH-F-MWCNT) and Au nanoparticles synthesized by the radiation method was fabricated for ethanol sensing. A higher sensing efficiency for ethanol for the ECL biosensor prepared by PAAc-g-MWCNT was measured compared to that of the ECL biosensor prepared by PMAc-g-MWCNT, and purified MWCNT. Experimental parameters affecting ethanol detection were also examined in terms of pH and the content of PAAc-g-MWCNT in Nafion. Little interference of other compounds was observed for the assay of ethanol. Results suggest this ECL biosensor could be applied for ethanol detection in real samples.
format Online
Article
Text
id pubmed-3345825
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-33458252012-05-09 Development of an Electrogenerated Chemiluminescence Biosensor using Carboxylic acid-functionalized MWCNT and Au Nanoparticles Piao, Ming-Hua Yang, Dae-Soo Yoon, Kuk-Ro Lee, Seung-Ho Choi, Seong-Ho Sensors (Basel) Communication A COOH-F-MWCNT-Nafion-Ru(bpy)(3)(2+)-Au-ADH electrogenerated chemiluminescence (ECL) electrode using COOH-functionalized MWCNT (COOH-F-MWCNT) and Au nanoparticles synthesized by the radiation method was fabricated for ethanol sensing. A higher sensing efficiency for ethanol for the ECL biosensor prepared by PAAc-g-MWCNT was measured compared to that of the ECL biosensor prepared by PMAc-g-MWCNT, and purified MWCNT. Experimental parameters affecting ethanol detection were also examined in terms of pH and the content of PAAc-g-MWCNT in Nafion. Little interference of other compounds was observed for the assay of ethanol. Results suggest this ECL biosensor could be applied for ethanol detection in real samples. Molecular Diversity Preservation International (MDPI) 2009-03-10 /pmc/articles/PMC3345825/ /pubmed/22573979 http://dx.doi.org/10.3390/s90301662 Text en © 2009 by the authors; licensee MDPI, Basel, Switzerland This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Communication
Piao, Ming-Hua
Yang, Dae-Soo
Yoon, Kuk-Ro
Lee, Seung-Ho
Choi, Seong-Ho
Development of an Electrogenerated Chemiluminescence Biosensor using Carboxylic acid-functionalized MWCNT and Au Nanoparticles
title Development of an Electrogenerated Chemiluminescence Biosensor using Carboxylic acid-functionalized MWCNT and Au Nanoparticles
title_full Development of an Electrogenerated Chemiluminescence Biosensor using Carboxylic acid-functionalized MWCNT and Au Nanoparticles
title_fullStr Development of an Electrogenerated Chemiluminescence Biosensor using Carboxylic acid-functionalized MWCNT and Au Nanoparticles
title_full_unstemmed Development of an Electrogenerated Chemiluminescence Biosensor using Carboxylic acid-functionalized MWCNT and Au Nanoparticles
title_short Development of an Electrogenerated Chemiluminescence Biosensor using Carboxylic acid-functionalized MWCNT and Au Nanoparticles
title_sort development of an electrogenerated chemiluminescence biosensor using carboxylic acid-functionalized mwcnt and au nanoparticles
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3345825/
https://www.ncbi.nlm.nih.gov/pubmed/22573979
http://dx.doi.org/10.3390/s90301662
work_keys_str_mv AT piaominghua developmentofanelectrogeneratedchemiluminescencebiosensorusingcarboxylicacidfunctionalizedmwcntandaunanoparticles
AT yangdaesoo developmentofanelectrogeneratedchemiluminescencebiosensorusingcarboxylicacidfunctionalizedmwcntandaunanoparticles
AT yoonkukro developmentofanelectrogeneratedchemiluminescencebiosensorusingcarboxylicacidfunctionalizedmwcntandaunanoparticles
AT leeseungho developmentofanelectrogeneratedchemiluminescencebiosensorusingcarboxylicacidfunctionalizedmwcntandaunanoparticles
AT choiseongho developmentofanelectrogeneratedchemiluminescencebiosensorusingcarboxylicacidfunctionalizedmwcntandaunanoparticles