Cargando…
Comparison of the novel ResPlex III assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007
Influenza virus is a major cause of disease worldwide. The accurate detection and further subtyping of influenza A viruses are important for epidemiologic surveillance, and subsequent comprehensive characterization of circulating influenza viruses is essential for the selection of an optimal vaccine...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3346937/ https://www.ncbi.nlm.nih.gov/pubmed/22012658 http://dx.doi.org/10.1007/s10096-011-1437-1 |
_version_ | 1782232249107742720 |
---|---|
author | Eggers, M. Roth, B. Schweiger, B. Schmid, M. Gregersen, J.-P. Enders, M. |
author_facet | Eggers, M. Roth, B. Schweiger, B. Schmid, M. Gregersen, J.-P. Enders, M. |
author_sort | Eggers, M. |
collection | PubMed |
description | Influenza virus is a major cause of disease worldwide. The accurate detection and further subtyping of influenza A viruses are important for epidemiologic surveillance, and subsequent comprehensive characterization of circulating influenza viruses is essential for the selection of an optimal vaccine composition. ResPlex III is a new multiplex reverse transcriptase polymerase chain reaction (RT-PCR)-based method for detecting, typing, and subtyping influenza virus in clinical specimens. The ResPlex III assay was compared with other methods with respect to sensitivity and accuracy, using 450 clinical specimens obtained from subjects throughout Germany during the 2006–2007 influenza season. Samples were analyzed for the presence of influenza virus in Madin-Darby canine kidney (MDCK) cells by rapid cell culture using peroxidase staining and conventional cell culture confirmed by hemagglutination inhibition assay, a rapid diagnostic assay (Directigen Flu A+B test; BD Diagnostic Systems, Heidelberg, Germany), in-house real-time RT-PCR (RRT-PCR), and ResPlex III (Qiagen, Hilden, Germany). ResPlex III had the highest sensitivity for detecting influenza virus in clinical specimens, followed by in-house RRT-PCR (96% compared with ResPlex III). Conventional cell culture in MDCK cells, rapid culture, and quick test assays were substantially less sensitive (55%, 72%, and 39%, respectively). Virus subtyping results were identical using ResPlex III and the standard virological subtyping method, hemagglutination inhibition. ResPlex III is a quick, accurate, and sensitive assay for detecting and typing influenza A and B viruses and subtyping influenza A viruses in clinical specimens, and might be considered for a supplemental role in worldwide seasonal and pandemic influenza surveillance. |
format | Online Article Text |
id | pubmed-3346937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-33469372012-05-24 Comparison of the novel ResPlex III assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007 Eggers, M. Roth, B. Schweiger, B. Schmid, M. Gregersen, J.-P. Enders, M. Eur J Clin Microbiol Infect Dis Research Article Influenza virus is a major cause of disease worldwide. The accurate detection and further subtyping of influenza A viruses are important for epidemiologic surveillance, and subsequent comprehensive characterization of circulating influenza viruses is essential for the selection of an optimal vaccine composition. ResPlex III is a new multiplex reverse transcriptase polymerase chain reaction (RT-PCR)-based method for detecting, typing, and subtyping influenza virus in clinical specimens. The ResPlex III assay was compared with other methods with respect to sensitivity and accuracy, using 450 clinical specimens obtained from subjects throughout Germany during the 2006–2007 influenza season. Samples were analyzed for the presence of influenza virus in Madin-Darby canine kidney (MDCK) cells by rapid cell culture using peroxidase staining and conventional cell culture confirmed by hemagglutination inhibition assay, a rapid diagnostic assay (Directigen Flu A+B test; BD Diagnostic Systems, Heidelberg, Germany), in-house real-time RT-PCR (RRT-PCR), and ResPlex III (Qiagen, Hilden, Germany). ResPlex III had the highest sensitivity for detecting influenza virus in clinical specimens, followed by in-house RRT-PCR (96% compared with ResPlex III). Conventional cell culture in MDCK cells, rapid culture, and quick test assays were substantially less sensitive (55%, 72%, and 39%, respectively). Virus subtyping results were identical using ResPlex III and the standard virological subtyping method, hemagglutination inhibition. ResPlex III is a quick, accurate, and sensitive assay for detecting and typing influenza A and B viruses and subtyping influenza A viruses in clinical specimens, and might be considered for a supplemental role in worldwide seasonal and pandemic influenza surveillance. Springer-Verlag 2011-10-20 2012 /pmc/articles/PMC3346937/ /pubmed/22012658 http://dx.doi.org/10.1007/s10096-011-1437-1 Text en © The Author(s) 2011 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Research Article Eggers, M. Roth, B. Schweiger, B. Schmid, M. Gregersen, J.-P. Enders, M. Comparison of the novel ResPlex III assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007 |
title | Comparison of the novel ResPlex III assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007 |
title_full | Comparison of the novel ResPlex III assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007 |
title_fullStr | Comparison of the novel ResPlex III assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007 |
title_full_unstemmed | Comparison of the novel ResPlex III assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007 |
title_short | Comparison of the novel ResPlex III assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007 |
title_sort | comparison of the novel resplex iii assay and existing techniques for the detection and subtyping of influenza virus during the influenza season 2006–2007 |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3346937/ https://www.ncbi.nlm.nih.gov/pubmed/22012658 http://dx.doi.org/10.1007/s10096-011-1437-1 |
work_keys_str_mv | AT eggersm comparisonofthenovelresplexiiiassayandexistingtechniquesforthedetectionandsubtypingofinfluenzavirusduringtheinfluenzaseason20062007 AT rothb comparisonofthenovelresplexiiiassayandexistingtechniquesforthedetectionandsubtypingofinfluenzavirusduringtheinfluenzaseason20062007 AT schweigerb comparisonofthenovelresplexiiiassayandexistingtechniquesforthedetectionandsubtypingofinfluenzavirusduringtheinfluenzaseason20062007 AT schmidm comparisonofthenovelresplexiiiassayandexistingtechniquesforthedetectionandsubtypingofinfluenzavirusduringtheinfluenzaseason20062007 AT gregersenjp comparisonofthenovelresplexiiiassayandexistingtechniquesforthedetectionandsubtypingofinfluenzavirusduringtheinfluenzaseason20062007 AT endersm comparisonofthenovelresplexiiiassayandexistingtechniquesforthedetectionandsubtypingofinfluenzavirusduringtheinfluenzaseason20062007 |