Cargando…
RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma
A simple, accurate, and precise HPLC method was developed and validated for determination of rimonabant in human plasma. Following liquid-liquid extraction, chromatographic separation was accomplished using C18 column with mobile phase consisting of acetonitrile : water (90 : 10, v/v), drug was dete...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3347727/ https://www.ncbi.nlm.nih.gov/pubmed/22619744 http://dx.doi.org/10.1155/2012/625979 |
_version_ | 1782232317950951424 |
---|---|
author | Bankey, Shravan Tapadiya, Ganesh Lamale, Jasvant Jain, Deepti Saboo, Shweta Khadabadi, S. S. |
author_facet | Bankey, Shravan Tapadiya, Ganesh Lamale, Jasvant Jain, Deepti Saboo, Shweta Khadabadi, S. S. |
author_sort | Bankey, Shravan |
collection | PubMed |
description | A simple, accurate, and precise HPLC method was developed and validated for determination of rimonabant in human plasma. Following liquid-liquid extraction, chromatographic separation was accomplished using C18 column with mobile phase consisting of acetonitrile : water (90 : 10, v/v), drug was detected at 260 nm using UVdetector. The LOD and LOQ were 3.0 and 10.0 μg/L, respectively. The method is linear in the interval 50.0–1000.0 μg/L. The average extraction recovery of drug from plasma was found to be 92.2%. The percent CV of the method was found to be less than 10.8%, and accuracy was found between 94.5 and 106.7%. The assay may be applied to a pharmacokinetic and bioequivalence study of rimonabant. |
format | Online Article Text |
id | pubmed-3347727 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-33477272012-05-22 RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma Bankey, Shravan Tapadiya, Ganesh Lamale, Jasvant Jain, Deepti Saboo, Shweta Khadabadi, S. S. J Anal Methods Chem Research Article A simple, accurate, and precise HPLC method was developed and validated for determination of rimonabant in human plasma. Following liquid-liquid extraction, chromatographic separation was accomplished using C18 column with mobile phase consisting of acetonitrile : water (90 : 10, v/v), drug was detected at 260 nm using UVdetector. The LOD and LOQ were 3.0 and 10.0 μg/L, respectively. The method is linear in the interval 50.0–1000.0 μg/L. The average extraction recovery of drug from plasma was found to be 92.2%. The percent CV of the method was found to be less than 10.8%, and accuracy was found between 94.5 and 106.7%. The assay may be applied to a pharmacokinetic and bioequivalence study of rimonabant. Hindawi Publishing Corporation 2012 2012-04-23 /pmc/articles/PMC3347727/ /pubmed/22619744 http://dx.doi.org/10.1155/2012/625979 Text en Copyright © 2012 Shravan Bankey et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Bankey, Shravan Tapadiya, Ganesh Lamale, Jasvant Jain, Deepti Saboo, Shweta Khadabadi, S. S. RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma |
title | RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma |
title_full | RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma |
title_fullStr | RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma |
title_full_unstemmed | RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma |
title_short | RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma |
title_sort | rp-hplc method development and its validation for quantitative determination of rimonabant in human plasma |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3347727/ https://www.ncbi.nlm.nih.gov/pubmed/22619744 http://dx.doi.org/10.1155/2012/625979 |
work_keys_str_mv | AT bankeyshravan rphplcmethoddevelopmentanditsvalidationforquantitativedeterminationofrimonabantinhumanplasma AT tapadiyaganesh rphplcmethoddevelopmentanditsvalidationforquantitativedeterminationofrimonabantinhumanplasma AT lamalejasvant rphplcmethoddevelopmentanditsvalidationforquantitativedeterminationofrimonabantinhumanplasma AT jaindeepti rphplcmethoddevelopmentanditsvalidationforquantitativedeterminationofrimonabantinhumanplasma AT sabooshweta rphplcmethoddevelopmentanditsvalidationforquantitativedeterminationofrimonabantinhumanplasma AT khadabadiss rphplcmethoddevelopmentanditsvalidationforquantitativedeterminationofrimonabantinhumanplasma |