Cargando…

Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study

Purpose. To investigate the effect of low tube voltage (80 kV) on image quality, radiation dose, and low-contrast detectability (LCD) at abdominal computed tomography (CT). Materials and Methods. A phantom containing low-contrast objects was scanned with a CT scanner at 80 and 120 kV, with tube curr...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Kun, Wang, Ling, Li, Rui, Lin, Jie, Zheng, Xiangwu, Cao, Guoquan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3347747/
https://www.ncbi.nlm.nih.gov/pubmed/22619490
http://dx.doi.org/10.1155/2012/130169
_version_ 1782232319520669696
author Tang, Kun
Wang, Ling
Li, Rui
Lin, Jie
Zheng, Xiangwu
Cao, Guoquan
author_facet Tang, Kun
Wang, Ling
Li, Rui
Lin, Jie
Zheng, Xiangwu
Cao, Guoquan
author_sort Tang, Kun
collection PubMed
description Purpose. To investigate the effect of low tube voltage (80 kV) on image quality, radiation dose, and low-contrast detectability (LCD) at abdominal computed tomography (CT). Materials and Methods. A phantom containing low-contrast objects was scanned with a CT scanner at 80 and 120 kV, with tube current-time product settings at 150–650 mAs. The differences between image noise, contrast-to-noise ratio (CNR), and scores of LCD obtained with 80 kV at 150–650 mAs and those obtained with 120 kV at 300 mAs were compared respectively. Results. The image noise substantially increased with low tube voltage. However, with identical dose, use of 80 kV resulted in higher CNR compared with CNR at 120 kV. There were no statistically significant difference in CNR and scores of LCD between 120 kV at 300 mAs and 80 kV at 550–650 mAs (P > 0.05). The relative dose delivered at 80 kV ranged from 58% at 550 mAs to 68% at 650 mAs. Conclusion. With a reduction of the tube voltage from 120 kV to 80 kV at abdominal CT, the radiation dose can be reduced by 32% to 42% without degradation of CNR and LCD.
format Online
Article
Text
id pubmed-3347747
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33477472012-05-22 Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study Tang, Kun Wang, Ling Li, Rui Lin, Jie Zheng, Xiangwu Cao, Guoquan J Biomed Biotechnol Research Article Purpose. To investigate the effect of low tube voltage (80 kV) on image quality, radiation dose, and low-contrast detectability (LCD) at abdominal computed tomography (CT). Materials and Methods. A phantom containing low-contrast objects was scanned with a CT scanner at 80 and 120 kV, with tube current-time product settings at 150–650 mAs. The differences between image noise, contrast-to-noise ratio (CNR), and scores of LCD obtained with 80 kV at 150–650 mAs and those obtained with 120 kV at 300 mAs were compared respectively. Results. The image noise substantially increased with low tube voltage. However, with identical dose, use of 80 kV resulted in higher CNR compared with CNR at 120 kV. There were no statistically significant difference in CNR and scores of LCD between 120 kV at 300 mAs and 80 kV at 550–650 mAs (P > 0.05). The relative dose delivered at 80 kV ranged from 58% at 550 mAs to 68% at 650 mAs. Conclusion. With a reduction of the tube voltage from 120 kV to 80 kV at abdominal CT, the radiation dose can be reduced by 32% to 42% without degradation of CNR and LCD. Hindawi Publishing Corporation 2012 2012-04-23 /pmc/articles/PMC3347747/ /pubmed/22619490 http://dx.doi.org/10.1155/2012/130169 Text en Copyright © 2012 Kun Tang et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Tang, Kun
Wang, Ling
Li, Rui
Lin, Jie
Zheng, Xiangwu
Cao, Guoquan
Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study
title Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study
title_full Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study
title_fullStr Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study
title_full_unstemmed Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study
title_short Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study
title_sort effect of low tube voltage on image quality, radiation dose, and low-contrast detectability at abdominal multidetector ct: phantom study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3347747/
https://www.ncbi.nlm.nih.gov/pubmed/22619490
http://dx.doi.org/10.1155/2012/130169
work_keys_str_mv AT tangkun effectoflowtubevoltageonimagequalityradiationdoseandlowcontrastdetectabilityatabdominalmultidetectorctphantomstudy
AT wangling effectoflowtubevoltageonimagequalityradiationdoseandlowcontrastdetectabilityatabdominalmultidetectorctphantomstudy
AT lirui effectoflowtubevoltageonimagequalityradiationdoseandlowcontrastdetectabilityatabdominalmultidetectorctphantomstudy
AT linjie effectoflowtubevoltageonimagequalityradiationdoseandlowcontrastdetectabilityatabdominalmultidetectorctphantomstudy
AT zhengxiangwu effectoflowtubevoltageonimagequalityradiationdoseandlowcontrastdetectabilityatabdominalmultidetectorctphantomstudy
AT caoguoquan effectoflowtubevoltageonimagequalityradiationdoseandlowcontrastdetectabilityatabdominalmultidetectorctphantomstudy