Cargando…
Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials
Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Scientific World Journal
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3349102/ https://www.ncbi.nlm.nih.gov/pubmed/22619599 http://dx.doi.org/10.1100/2012/156186 |
_version_ | 1782232464841768960 |
---|---|
author | Safari, Mohammad Reza Rowe, Philip Buis, Arjan |
author_facet | Safari, Mohammad Reza Rowe, Philip Buis, Arjan |
author_sort | Safari, Mohammad Reza |
collection | PubMed |
description | Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements. |
format | Online Article Text |
id | pubmed-3349102 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Scientific World Journal |
record_format | MEDLINE/PubMed |
spelling | pubmed-33491022012-05-22 Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials Safari, Mohammad Reza Rowe, Philip Buis, Arjan ScientificWorldJournal Research Article Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements. The Scientific World Journal 2012-04-24 /pmc/articles/PMC3349102/ /pubmed/22619599 http://dx.doi.org/10.1100/2012/156186 Text en Copyright © 2012 Mohammad Reza Safari et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Safari, Mohammad Reza Rowe, Philip Buis, Arjan Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials |
title | Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials |
title_full | Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials |
title_fullStr | Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials |
title_full_unstemmed | Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials |
title_short | Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials |
title_sort | accuracy verification of magnetic resonance imaging (mri) technology for lower-limb prosthetic research: utilising animal soft tissue specimen and common socket casting materials |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3349102/ https://www.ncbi.nlm.nih.gov/pubmed/22619599 http://dx.doi.org/10.1100/2012/156186 |
work_keys_str_mv | AT safarimohammadreza accuracyverificationofmagneticresonanceimagingmritechnologyforlowerlimbprostheticresearchutilisinganimalsofttissuespecimenandcommonsocketcastingmaterials AT rowephilip accuracyverificationofmagneticresonanceimagingmritechnologyforlowerlimbprostheticresearchutilisinganimalsofttissuespecimenandcommonsocketcastingmaterials AT buisarjan accuracyverificationofmagneticresonanceimagingmritechnologyforlowerlimbprostheticresearchutilisinganimalsofttissuespecimenandcommonsocketcastingmaterials |