Cargando…

A technique for pediatric total skin electron irradiation

BACKGROUND: Total skin electron irradiation (TSEI) is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and...

Descripción completa

Detalles Bibliográficos
Autores principales: Bao, Qinan, Hrycushko, Brian A, Dugas, Joseph P, Hager, Frederick H, Solberg, Timothy D
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3349519/
https://www.ncbi.nlm.nih.gov/pubmed/22433063
http://dx.doi.org/10.1186/1748-717X-7-40
_version_ 1782232514562097152
author Bao, Qinan
Hrycushko, Brian A
Dugas, Joseph P
Hager, Frederick H
Solberg, Timothy D
author_facet Bao, Qinan
Hrycushko, Brian A
Dugas, Joseph P
Hager, Frederick H
Solberg, Timothy D
author_sort Bao, Qinan
collection PubMed
description BACKGROUND: Total skin electron irradiation (TSEI) is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and quality assurance (QA) methods for implementing a modified Stanford technique using a rotating harness system to position sedated pediatric patients treated with electrons to the total skin. METHODS AND RESULTS: Commissioning of pediatric TSEI consisted of absolute calibration, measurement of dosimetric parameters, and subsequent verification in a pediatric patient sized cylindrical phantom using radiographic film and optically stimulated luminance (OSL) dosimeters. The depth of dose penetration under TSEI treatment condition was evaluated using radiographic film sandwiched in the phantom and demonstrated a 2 cm penetration depth with the maximum dose located at the phantom surface. Dosimetry measurements on the cylindrical phantom and in-vivo measurements from the patients suggested that, the factor relating the skin and calibration point doses (i.e., the B-factor) was larger for the pediatric TSEI treatments as compared to adult TSEI treatments. Custom made equipment, including a rotating plate and harness, was fabricated and added to a standard total body irradiation stand and tested to facilitate patient setup under sedated condition. A pediatric TSEI QA program, consisting of daily output, energy, flatness, and symmetry measurements as well as in-vivo dosimetry verification for the first cycle was developed. With a long interval between pediatric TSEI cases, absolute dosimetry was also repeated as part of the QA program. In-vivo dosimetry for the first two infants showed that a dose of ± 10% of the prescription dose can be achieved over the entire patient body. CONCLUSION: Though pediatric leukemia cutis and the subsequent need for TSEI are rare, the ability to commission the technique on a modified TBI stand is appealing for clinical implementation and has been successfully used for the treatment of two pediatric patients at our institution.
format Online
Article
Text
id pubmed-3349519
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33495192012-05-11 A technique for pediatric total skin electron irradiation Bao, Qinan Hrycushko, Brian A Dugas, Joseph P Hager, Frederick H Solberg, Timothy D Radiat Oncol Methodology BACKGROUND: Total skin electron irradiation (TSEI) is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and quality assurance (QA) methods for implementing a modified Stanford technique using a rotating harness system to position sedated pediatric patients treated with electrons to the total skin. METHODS AND RESULTS: Commissioning of pediatric TSEI consisted of absolute calibration, measurement of dosimetric parameters, and subsequent verification in a pediatric patient sized cylindrical phantom using radiographic film and optically stimulated luminance (OSL) dosimeters. The depth of dose penetration under TSEI treatment condition was evaluated using radiographic film sandwiched in the phantom and demonstrated a 2 cm penetration depth with the maximum dose located at the phantom surface. Dosimetry measurements on the cylindrical phantom and in-vivo measurements from the patients suggested that, the factor relating the skin and calibration point doses (i.e., the B-factor) was larger for the pediatric TSEI treatments as compared to adult TSEI treatments. Custom made equipment, including a rotating plate and harness, was fabricated and added to a standard total body irradiation stand and tested to facilitate patient setup under sedated condition. A pediatric TSEI QA program, consisting of daily output, energy, flatness, and symmetry measurements as well as in-vivo dosimetry verification for the first cycle was developed. With a long interval between pediatric TSEI cases, absolute dosimetry was also repeated as part of the QA program. In-vivo dosimetry for the first two infants showed that a dose of ± 10% of the prescription dose can be achieved over the entire patient body. CONCLUSION: Though pediatric leukemia cutis and the subsequent need for TSEI are rare, the ability to commission the technique on a modified TBI stand is appealing for clinical implementation and has been successfully used for the treatment of two pediatric patients at our institution. BioMed Central 2012-03-20 /pmc/articles/PMC3349519/ /pubmed/22433063 http://dx.doi.org/10.1186/1748-717X-7-40 Text en Copyright ©2012 Bao et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Bao, Qinan
Hrycushko, Brian A
Dugas, Joseph P
Hager, Frederick H
Solberg, Timothy D
A technique for pediatric total skin electron irradiation
title A technique for pediatric total skin electron irradiation
title_full A technique for pediatric total skin electron irradiation
title_fullStr A technique for pediatric total skin electron irradiation
title_full_unstemmed A technique for pediatric total skin electron irradiation
title_short A technique for pediatric total skin electron irradiation
title_sort technique for pediatric total skin electron irradiation
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3349519/
https://www.ncbi.nlm.nih.gov/pubmed/22433063
http://dx.doi.org/10.1186/1748-717X-7-40
work_keys_str_mv AT baoqinan atechniqueforpediatrictotalskinelectronirradiation
AT hrycushkobriana atechniqueforpediatrictotalskinelectronirradiation
AT dugasjosephp atechniqueforpediatrictotalskinelectronirradiation
AT hagerfrederickh atechniqueforpediatrictotalskinelectronirradiation
AT solbergtimothyd atechniqueforpediatrictotalskinelectronirradiation
AT baoqinan techniqueforpediatrictotalskinelectronirradiation
AT hrycushkobriana techniqueforpediatrictotalskinelectronirradiation
AT dugasjosephp techniqueforpediatrictotalskinelectronirradiation
AT hagerfrederickh techniqueforpediatrictotalskinelectronirradiation
AT solbergtimothyd techniqueforpediatrictotalskinelectronirradiation