Cargando…

Partial Nephrectomy in a Patient with a Left Ventricular Assist Device

Left ventricular assist device (LVAD) use has increased as a bridge to heart transplant as well as destination therapy in patients with severe heart failure. Presence of LVAD is not a contraindication to noncardiac surgery but does present special challenges to the surgical, anesthesia, and cardiac...

Descripción completa

Detalles Bibliográficos
Autores principales: Manger, Jules P., Kern, John A., Krupski, Tracey L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350215/
https://www.ncbi.nlm.nih.gov/pubmed/22606616
http://dx.doi.org/10.1155/2011/526903
_version_ 1782232624791552000
author Manger, Jules P.
Kern, John A.
Krupski, Tracey L.
author_facet Manger, Jules P.
Kern, John A.
Krupski, Tracey L.
author_sort Manger, Jules P.
collection PubMed
description Left ventricular assist device (LVAD) use has increased as a bridge to heart transplant as well as destination therapy in patients with severe heart failure. Presence of LVAD is not a contraindication to noncardiac surgery but does present special challenges to the surgical, anesthesia, and cardiac teams. We present the case of a 40-year-old woman with idiopathic cardiomyopathy necessitating LVAD who underwent left partial nephrectomy for a renal mass. She had undergone three nondiagnostic percutaneous image-guided biopsies. Left partial nephrectomy was performed. Perioperative care was without incident due to careful oversight by a multidisciplinary team. Pathology revealed high-grade clear cell renal cell carcinoma (RCC) with negative margins. Polytetrafluoroethylene (PTFE) bolsters were misidentified six months postoperatively on computed tomography (CT) at an outside institution as a retained laparotomy sponge. This is, to our knowledge, the first report of a partial nephrectomy performed in a patient with LVAD.
format Online
Article
Text
id pubmed-3350215
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33502152012-05-17 Partial Nephrectomy in a Patient with a Left Ventricular Assist Device Manger, Jules P. Kern, John A. Krupski, Tracey L. Case Rep Urol Case Report Left ventricular assist device (LVAD) use has increased as a bridge to heart transplant as well as destination therapy in patients with severe heart failure. Presence of LVAD is not a contraindication to noncardiac surgery but does present special challenges to the surgical, anesthesia, and cardiac teams. We present the case of a 40-year-old woman with idiopathic cardiomyopathy necessitating LVAD who underwent left partial nephrectomy for a renal mass. She had undergone three nondiagnostic percutaneous image-guided biopsies. Left partial nephrectomy was performed. Perioperative care was without incident due to careful oversight by a multidisciplinary team. Pathology revealed high-grade clear cell renal cell carcinoma (RCC) with negative margins. Polytetrafluoroethylene (PTFE) bolsters were misidentified six months postoperatively on computed tomography (CT) at an outside institution as a retained laparotomy sponge. This is, to our knowledge, the first report of a partial nephrectomy performed in a patient with LVAD. Hindawi Publishing Corporation 2011 2011-09-22 /pmc/articles/PMC3350215/ /pubmed/22606616 http://dx.doi.org/10.1155/2011/526903 Text en Copyright © 2011 Jules P. Manger et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Manger, Jules P.
Kern, John A.
Krupski, Tracey L.
Partial Nephrectomy in a Patient with a Left Ventricular Assist Device
title Partial Nephrectomy in a Patient with a Left Ventricular Assist Device
title_full Partial Nephrectomy in a Patient with a Left Ventricular Assist Device
title_fullStr Partial Nephrectomy in a Patient with a Left Ventricular Assist Device
title_full_unstemmed Partial Nephrectomy in a Patient with a Left Ventricular Assist Device
title_short Partial Nephrectomy in a Patient with a Left Ventricular Assist Device
title_sort partial nephrectomy in a patient with a left ventricular assist device
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350215/
https://www.ncbi.nlm.nih.gov/pubmed/22606616
http://dx.doi.org/10.1155/2011/526903
work_keys_str_mv AT mangerjulesp partialnephrectomyinapatientwithaleftventricularassistdevice
AT kernjohna partialnephrectomyinapatientwithaleftventricularassistdevice
AT krupskitraceyl partialnephrectomyinapatientwithaleftventricularassistdevice