Cargando…

Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma

Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old...

Descripción completa

Detalles Bibliográficos
Autores principales: Ranganath, Akshatha, Hashim, Adnan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350242/
https://www.ncbi.nlm.nih.gov/pubmed/22611505
http://dx.doi.org/10.1155/2011/183647
_version_ 1782232631004364800
author Ranganath, Akshatha
Hashim, Adnan
author_facet Ranganath, Akshatha
Hashim, Adnan
author_sort Ranganath, Akshatha
collection PubMed
description Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with pericardial patch graft for management of refractory glaucoma secondary to congenital ectropion uveae. The glaucoma tube was exposed due to erosion of the overlying conjunctiva with no visible pericardial graft. After control of active infection, he underwent tube revision surgery whereby the exposed tube was retained and repatched with a double-thickness pericardial patch graft. He did well following surgery with good control of IOP and restoration of vision. Conjunctival dehiscence with graft melting over the GDI tube presented a major risk factor for endophthalmitis. Prompt surgical revision of an exposed tube is highly recommended to avoid ocular morbidity.
format Online
Article
Text
id pubmed-3350242
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33502422012-05-18 Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma Ranganath, Akshatha Hashim, Adnan Case Rep Ophthalmol Med Case Report Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with pericardial patch graft for management of refractory glaucoma secondary to congenital ectropion uveae. The glaucoma tube was exposed due to erosion of the overlying conjunctiva with no visible pericardial graft. After control of active infection, he underwent tube revision surgery whereby the exposed tube was retained and repatched with a double-thickness pericardial patch graft. He did well following surgery with good control of IOP and restoration of vision. Conjunctival dehiscence with graft melting over the GDI tube presented a major risk factor for endophthalmitis. Prompt surgical revision of an exposed tube is highly recommended to avoid ocular morbidity. Hindawi Publishing Corporation 2011 2011-12-17 /pmc/articles/PMC3350242/ /pubmed/22611505 http://dx.doi.org/10.1155/2011/183647 Text en Copyright © 2011 A. Ranganath and A. Hashim. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Ranganath, Akshatha
Hashim, Adnan
Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma
title Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma
title_full Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma
title_fullStr Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma
title_full_unstemmed Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma
title_short Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma
title_sort late-onset endophthalmitis secondary to exposed glaucoma tube implant in a rare case of paediatric glaucoma
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350242/
https://www.ncbi.nlm.nih.gov/pubmed/22611505
http://dx.doi.org/10.1155/2011/183647
work_keys_str_mv AT ranganathakshatha lateonsetendophthalmitissecondarytoexposedglaucomatubeimplantinararecaseofpaediatricglaucoma
AT hashimadnan lateonsetendophthalmitissecondarytoexposedglaucomatubeimplantinararecaseofpaediatricglaucoma