Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma

BACKGROUND: Changes in maximum standardised uptake values (SUV(max)) between serial PET/CT studies are used to determine disease progression or regression in oncologic patients. To measure these changes manually can be time consuming in a clinical routine. A semi-automatic method for calculation of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ly, John, Garpered, Sabine, Höglund, Peter, Jönsson, Eskil, Valind, Sven, Edenbrandt, Lars, Wollmer, Per
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350379/
https://www.ncbi.nlm.nih.gov/pubmed/22471689
http://dx.doi.org/10.1186/1471-2342-12-6
_version_ 1782232650241540096
author Ly, John
Garpered, Sabine
Höglund, Peter
Jönsson, Eskil
Valind, Sven
Edenbrandt, Lars
Wollmer, Per
author_facet Ly, John
Garpered, Sabine
Höglund, Peter
Jönsson, Eskil
Valind, Sven
Edenbrandt, Lars
Wollmer, Per
author_sort Ly, John
collection PubMed
description BACKGROUND: Changes in maximum standardised uptake values (SUV(max)) between serial PET/CT studies are used to determine disease progression or regression in oncologic patients. To measure these changes manually can be time consuming in a clinical routine. A semi-automatic method for calculation of SUV(max )in serial PET/CT studies was developed and compared to a conventional manual method. The semi-automatic method first aligns the serial PET/CT studies based on the CT images. Thereafter, the reader selects an abnormal lesion in one of the PET studies. After this manual step, the program automatically detects the corresponding lesion in the other PET study, segments the two lesions and calculates the SUV(max )in both studies as well as the difference between the SUV(max )values. The results of the semi-automatic analysis were compared to that of a manual SUV(max )analysis using a Philips PET/CT workstation. Three readers did the SUV(max )readings in both methods. Sixteen patients with lung cancer or lymphoma who had undergone two PET/CT studies were included. There were a total of 26 lesions. RESULTS: Linear regression analysis of changes in SUV(max )show that intercepts and slopes are close to the line of identity for all readers (reader 1: intercept = 1.02, R(2 )= 0.96; reader 2: intercept = 0.97, R(2 )= 0.98; reader 3: intercept = 0.99, R(2 )= 0.98). Manual and semi-automatic method agreed in all cases whether SUV(max )had increased or decreased between the serial studies. The average time to measure SUV(max )changes in two serial PET/CT examinations was four to five times longer for the manual method compared to the semi-automatic method for all readers (reader 1: 53.7 vs. 10.5 s; reader 2: 27.3 vs. 6.9 s; reader 3: 47.5 vs. 9.5 s; p < 0.001 for all). CONCLUSIONS: Good agreement was shown in assessment of SUV(max )changes between manual and semi-automatic method. The semi-automatic analysis was four to five times faster to perform than the manual analysis. These findings show the feasibility of using semi-automatic methods for calculation of SUV(max )in clinical routine and encourage further development of programs using this type of methods.
format Online
Article
Text
id pubmed-3350379
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33503792012-05-12 Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma Ly, John Garpered, Sabine Höglund, Peter Jönsson, Eskil Valind, Sven Edenbrandt, Lars Wollmer, Per BMC Med Imaging Research Article BACKGROUND: Changes in maximum standardised uptake values (SUV(max)) between serial PET/CT studies are used to determine disease progression or regression in oncologic patients. To measure these changes manually can be time consuming in a clinical routine. A semi-automatic method for calculation of SUV(max )in serial PET/CT studies was developed and compared to a conventional manual method. The semi-automatic method first aligns the serial PET/CT studies based on the CT images. Thereafter, the reader selects an abnormal lesion in one of the PET studies. After this manual step, the program automatically detects the corresponding lesion in the other PET study, segments the two lesions and calculates the SUV(max )in both studies as well as the difference between the SUV(max )values. The results of the semi-automatic analysis were compared to that of a manual SUV(max )analysis using a Philips PET/CT workstation. Three readers did the SUV(max )readings in both methods. Sixteen patients with lung cancer or lymphoma who had undergone two PET/CT studies were included. There were a total of 26 lesions. RESULTS: Linear regression analysis of changes in SUV(max )show that intercepts and slopes are close to the line of identity for all readers (reader 1: intercept = 1.02, R(2 )= 0.96; reader 2: intercept = 0.97, R(2 )= 0.98; reader 3: intercept = 0.99, R(2 )= 0.98). Manual and semi-automatic method agreed in all cases whether SUV(max )had increased or decreased between the serial studies. The average time to measure SUV(max )changes in two serial PET/CT examinations was four to five times longer for the manual method compared to the semi-automatic method for all readers (reader 1: 53.7 vs. 10.5 s; reader 2: 27.3 vs. 6.9 s; reader 3: 47.5 vs. 9.5 s; p < 0.001 for all). CONCLUSIONS: Good agreement was shown in assessment of SUV(max )changes between manual and semi-automatic method. The semi-automatic analysis was four to five times faster to perform than the manual analysis. These findings show the feasibility of using semi-automatic methods for calculation of SUV(max )in clinical routine and encourage further development of programs using this type of methods. BioMed Central 2012-04-02 /pmc/articles/PMC3350379/ /pubmed/22471689 http://dx.doi.org/10.1186/1471-2342-12-6 Text en Copyright ©2012 Ly et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ly, John
Garpered, Sabine
Höglund, Peter
Jönsson, Eskil
Valind, Sven
Edenbrandt, Lars
Wollmer, Per
Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma
title Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma
title_full Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma
title_fullStr Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma
title_full_unstemmed Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma
title_short Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma
title_sort semi-automatic analysis of standard uptake values in serial pet/ct studies in patients with lung cancer and lymphoma
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350379/
https://www.ncbi.nlm.nih.gov/pubmed/22471689
http://dx.doi.org/10.1186/1471-2342-12-6
work_keys_str_mv AT lyjohn semiautomaticanalysisofstandarduptakevaluesinserialpetctstudiesinpatientswithlungcancerandlymphoma
AT garperedsabine semiautomaticanalysisofstandarduptakevaluesinserialpetctstudiesinpatientswithlungcancerandlymphoma
AT hoglundpeter semiautomaticanalysisofstandarduptakevaluesinserialpetctstudiesinpatientswithlungcancerandlymphoma
AT jonssoneskil semiautomaticanalysisofstandarduptakevaluesinserialpetctstudiesinpatientswithlungcancerandlymphoma
AT valindsven semiautomaticanalysisofstandarduptakevaluesinserialpetctstudiesinpatientswithlungcancerandlymphoma
AT edenbrandtlars semiautomaticanalysisofstandarduptakevaluesinserialpetctstudiesinpatientswithlungcancerandlymphoma
AT wollmerper semiautomaticanalysisofstandarduptakevaluesinserialpetctstudiesinpatientswithlungcancerandlymphoma