Cargando…

Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment

BACKGROUND: The short inversion time inversion recovery (STIR) black-blood technique has been used to visualize myocardial edema, and thus to differentiate acute from chronic myocardial lesions. However, some cardiovascular magnetic resonance (CMR) groups have reported variable image quality, and he...

Descripción completa

Detalles Bibliográficos
Autores principales: h-Ici, Darach O, Ridgway, John P, Kuehne, Titus, Berger, Felix, Plein, Sven, Sivananthan, Mohan, Messroghli, Daniel R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350411/
https://www.ncbi.nlm.nih.gov/pubmed/22455461
http://dx.doi.org/10.1186/1532-429X-14-22
_version_ 1782232657659166720
author h-Ici, Darach O
Ridgway, John P
Kuehne, Titus
Berger, Felix
Plein, Sven
Sivananthan, Mohan
Messroghli, Daniel R
author_facet h-Ici, Darach O
Ridgway, John P
Kuehne, Titus
Berger, Felix
Plein, Sven
Sivananthan, Mohan
Messroghli, Daniel R
author_sort h-Ici, Darach O
collection PubMed
description BACKGROUND: The short inversion time inversion recovery (STIR) black-blood technique has been used to visualize myocardial edema, and thus to differentiate acute from chronic myocardial lesions. However, some cardiovascular magnetic resonance (CMR) groups have reported variable image quality, and hence the diagnostic value of STIR in routine clinical practice has been put into question. The aim of our study was to analyze image quality and diagnostic performance of STIR using a set of pulse sequence parameters dedicated to edema detection, and to discuss possible factors that influence image quality. We hypothesized that STIR imaging is an accurate and robust way of detecting myocardial edema in non-selected patients with acute myocardial infarction. METHODS: Forty-six consecutive patients with acute myocardial infarction underwent CMR (day 4.5, +/- 1.6) including STIR for the assessment of myocardial edema and late gadolinium enhancement (LGE) for quantification of myocardial necrosis. Thirty of these patients underwent a follow-up CMR at approximately six months (195 +/- 39 days). Both STIR and LGE images were evaluated separately on a segmental basis for image quality as well as for presence and extent of myocardial hyper-intensity, with both visual and semi-quantitative (threshold-based) analysis. LGE was used as a reference standard for localization and extent of myocardial necrosis (acute) or scar (chronic). RESULTS: Image quality of STIR images was rated as diagnostic in 99.5% of cases. At the acute stage, the sensitivity and specificity of STIR to detect infarcted segments on visual assessment was 95% and 78% respectively, and on semi-quantitative assessment was 99% and 83%, respectively. STIR differentiated acutely from chronically infarcted segments with a sensitivity of 95% by both methods and with a specificity of 99% by visual assessment and 97% by semi-quantitative assessment. The extent of hyper-intense areas on acute STIR images was 85% larger than those on LGE images, with a larger myocardial salvage index in reperfused than in non-reperfused infarcts (p = 0.035). CONCLUSIONS: STIR with appropriate pulse sequence settings is accurate in detecting acute myocardial infarction (MI) and distinguishing acute from chronic MI with both visual and semi-quantitative analysis. Due to its unique technical characteristics, STIR should be regarded as an edema-weighted rather than a purely T2-weighted technique.
format Online
Article
Text
id pubmed-3350411
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33504112012-05-12 Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment h-Ici, Darach O Ridgway, John P Kuehne, Titus Berger, Felix Plein, Sven Sivananthan, Mohan Messroghli, Daniel R J Cardiovasc Magn Reson Research BACKGROUND: The short inversion time inversion recovery (STIR) black-blood technique has been used to visualize myocardial edema, and thus to differentiate acute from chronic myocardial lesions. However, some cardiovascular magnetic resonance (CMR) groups have reported variable image quality, and hence the diagnostic value of STIR in routine clinical practice has been put into question. The aim of our study was to analyze image quality and diagnostic performance of STIR using a set of pulse sequence parameters dedicated to edema detection, and to discuss possible factors that influence image quality. We hypothesized that STIR imaging is an accurate and robust way of detecting myocardial edema in non-selected patients with acute myocardial infarction. METHODS: Forty-six consecutive patients with acute myocardial infarction underwent CMR (day 4.5, +/- 1.6) including STIR for the assessment of myocardial edema and late gadolinium enhancement (LGE) for quantification of myocardial necrosis. Thirty of these patients underwent a follow-up CMR at approximately six months (195 +/- 39 days). Both STIR and LGE images were evaluated separately on a segmental basis for image quality as well as for presence and extent of myocardial hyper-intensity, with both visual and semi-quantitative (threshold-based) analysis. LGE was used as a reference standard for localization and extent of myocardial necrosis (acute) or scar (chronic). RESULTS: Image quality of STIR images was rated as diagnostic in 99.5% of cases. At the acute stage, the sensitivity and specificity of STIR to detect infarcted segments on visual assessment was 95% and 78% respectively, and on semi-quantitative assessment was 99% and 83%, respectively. STIR differentiated acutely from chronically infarcted segments with a sensitivity of 95% by both methods and with a specificity of 99% by visual assessment and 97% by semi-quantitative assessment. The extent of hyper-intense areas on acute STIR images was 85% larger than those on LGE images, with a larger myocardial salvage index in reperfused than in non-reperfused infarcts (p = 0.035). CONCLUSIONS: STIR with appropriate pulse sequence settings is accurate in detecting acute myocardial infarction (MI) and distinguishing acute from chronic MI with both visual and semi-quantitative analysis. Due to its unique technical characteristics, STIR should be regarded as an edema-weighted rather than a purely T2-weighted technique. BioMed Central 2012-03-28 /pmc/articles/PMC3350411/ /pubmed/22455461 http://dx.doi.org/10.1186/1532-429X-14-22 Text en Copyright ©2012 h-Ici et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
h-Ici, Darach O
Ridgway, John P
Kuehne, Titus
Berger, Felix
Plein, Sven
Sivananthan, Mohan
Messroghli, Daniel R
Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment
title Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment
title_full Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment
title_fullStr Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment
title_full_unstemmed Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment
title_short Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment
title_sort cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (stir) black-blood technique: diagnostic accuracy of visual and semi-quantitative assessment
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350411/
https://www.ncbi.nlm.nih.gov/pubmed/22455461
http://dx.doi.org/10.1186/1532-429X-14-22
work_keys_str_mv AT hicidaracho cardiovascularmagneticresonanceofmyocardialedemausingashortinversiontimeinversionrecoverystirblackbloodtechniquediagnosticaccuracyofvisualandsemiquantitativeassessment
AT ridgwayjohnp cardiovascularmagneticresonanceofmyocardialedemausingashortinversiontimeinversionrecoverystirblackbloodtechniquediagnosticaccuracyofvisualandsemiquantitativeassessment
AT kuehnetitus cardiovascularmagneticresonanceofmyocardialedemausingashortinversiontimeinversionrecoverystirblackbloodtechniquediagnosticaccuracyofvisualandsemiquantitativeassessment
AT bergerfelix cardiovascularmagneticresonanceofmyocardialedemausingashortinversiontimeinversionrecoverystirblackbloodtechniquediagnosticaccuracyofvisualandsemiquantitativeassessment
AT pleinsven cardiovascularmagneticresonanceofmyocardialedemausingashortinversiontimeinversionrecoverystirblackbloodtechniquediagnosticaccuracyofvisualandsemiquantitativeassessment
AT sivananthanmohan cardiovascularmagneticresonanceofmyocardialedemausingashortinversiontimeinversionrecoverystirblackbloodtechniquediagnosticaccuracyofvisualandsemiquantitativeassessment
AT messroghlidanielr cardiovascularmagneticresonanceofmyocardialedemausingashortinversiontimeinversionrecoverystirblackbloodtechniquediagnosticaccuracyofvisualandsemiquantitativeassessment