A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study
This paper describes the influence of human toe movement on blood flow and the design of a toe joint passive motion system for preventing pressure ulcers. First, we measured lower extremity blood flow in the foot during active and passive motion of the toe to facilitate the design of new rehabilitat...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350992/ https://www.ncbi.nlm.nih.gov/pubmed/22619724 http://dx.doi.org/10.1155/2012/541383 |
_version_ | 1782232723410124800 |
---|---|
author | Hosono, Minako Ino, Shuichi Sato, Mitsuru Yamashita, Kazuhiko Izumi, Takashi |
author_facet | Hosono, Minako Ino, Shuichi Sato, Mitsuru Yamashita, Kazuhiko Izumi, Takashi |
author_sort | Hosono, Minako |
collection | PubMed |
description | This paper describes the influence of human toe movement on blood flow and the design of a toe joint passive motion system for preventing pressure ulcers. First, we measured lower extremity blood flow in the foot during active and passive motion of the toe to facilitate the design of new rehabilitation equipment. Also, the flexion and extension angles and the force of the toe joints were measured to determine appropriate specifications for the system. Increases in blood flow were observed at the external malleolus during movement. Flexion and extension angles and the force of the toe joints were found to differ significantly among participants. It is shown that a toe joint passive motion system can be effective in preventing pressure ulcers. On the basis of these results, a device using alloys of metal hydride (MH) as an actuator that is suitable for the system to initiate toe motion, was developed. |
format | Online Article Text |
id | pubmed-3350992 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-33509922012-05-22 A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study Hosono, Minako Ino, Shuichi Sato, Mitsuru Yamashita, Kazuhiko Izumi, Takashi Rehabil Res Pract Research Article This paper describes the influence of human toe movement on blood flow and the design of a toe joint passive motion system for preventing pressure ulcers. First, we measured lower extremity blood flow in the foot during active and passive motion of the toe to facilitate the design of new rehabilitation equipment. Also, the flexion and extension angles and the force of the toe joints were measured to determine appropriate specifications for the system. Increases in blood flow were observed at the external malleolus during movement. Flexion and extension angles and the force of the toe joints were found to differ significantly among participants. It is shown that a toe joint passive motion system can be effective in preventing pressure ulcers. On the basis of these results, a device using alloys of metal hydride (MH) as an actuator that is suitable for the system to initiate toe motion, was developed. Hindawi Publishing Corporation 2012 2012-04-29 /pmc/articles/PMC3350992/ /pubmed/22619724 http://dx.doi.org/10.1155/2012/541383 Text en Copyright © 2012 Minako Hosono et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Hosono, Minako Ino, Shuichi Sato, Mitsuru Yamashita, Kazuhiko Izumi, Takashi A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study |
title | A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study |
title_full | A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study |
title_fullStr | A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study |
title_full_unstemmed | A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study |
title_short | A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study |
title_sort | system utilizing metal hydride actuators to achieve passive motion of toe joints for prevention of pressure ulcers: a pilot study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350992/ https://www.ncbi.nlm.nih.gov/pubmed/22619724 http://dx.doi.org/10.1155/2012/541383 |
work_keys_str_mv | AT hosonominako asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT inoshuichi asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT satomitsuru asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT yamashitakazuhiko asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT izumitakashi asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT hosonominako systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT inoshuichi systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT satomitsuru systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT yamashitakazuhiko systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy AT izumitakashi systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy |