A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study

This paper describes the influence of human toe movement on blood flow and the design of a toe joint passive motion system for preventing pressure ulcers. First, we measured lower extremity blood flow in the foot during active and passive motion of the toe to facilitate the design of new rehabilitat...

Descripción completa

Detalles Bibliográficos
Autores principales: Hosono, Minako, Ino, Shuichi, Sato, Mitsuru, Yamashita, Kazuhiko, Izumi, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350992/
https://www.ncbi.nlm.nih.gov/pubmed/22619724
http://dx.doi.org/10.1155/2012/541383
_version_ 1782232723410124800
author Hosono, Minako
Ino, Shuichi
Sato, Mitsuru
Yamashita, Kazuhiko
Izumi, Takashi
author_facet Hosono, Minako
Ino, Shuichi
Sato, Mitsuru
Yamashita, Kazuhiko
Izumi, Takashi
author_sort Hosono, Minako
collection PubMed
description This paper describes the influence of human toe movement on blood flow and the design of a toe joint passive motion system for preventing pressure ulcers. First, we measured lower extremity blood flow in the foot during active and passive motion of the toe to facilitate the design of new rehabilitation equipment. Also, the flexion and extension angles and the force of the toe joints were measured to determine appropriate specifications for the system. Increases in blood flow were observed at the external malleolus during movement. Flexion and extension angles and the force of the toe joints were found to differ significantly among participants. It is shown that a toe joint passive motion system can be effective in preventing pressure ulcers. On the basis of these results, a device using alloys of metal hydride (MH) as an actuator that is suitable for the system to initiate toe motion, was developed.
format Online
Article
Text
id pubmed-3350992
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33509922012-05-22 A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study Hosono, Minako Ino, Shuichi Sato, Mitsuru Yamashita, Kazuhiko Izumi, Takashi Rehabil Res Pract Research Article This paper describes the influence of human toe movement on blood flow and the design of a toe joint passive motion system for preventing pressure ulcers. First, we measured lower extremity blood flow in the foot during active and passive motion of the toe to facilitate the design of new rehabilitation equipment. Also, the flexion and extension angles and the force of the toe joints were measured to determine appropriate specifications for the system. Increases in blood flow were observed at the external malleolus during movement. Flexion and extension angles and the force of the toe joints were found to differ significantly among participants. It is shown that a toe joint passive motion system can be effective in preventing pressure ulcers. On the basis of these results, a device using alloys of metal hydride (MH) as an actuator that is suitable for the system to initiate toe motion, was developed. Hindawi Publishing Corporation 2012 2012-04-29 /pmc/articles/PMC3350992/ /pubmed/22619724 http://dx.doi.org/10.1155/2012/541383 Text en Copyright © 2012 Minako Hosono et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hosono, Minako
Ino, Shuichi
Sato, Mitsuru
Yamashita, Kazuhiko
Izumi, Takashi
A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study
title A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study
title_full A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study
title_fullStr A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study
title_full_unstemmed A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study
title_short A System Utilizing Metal Hydride Actuators to Achieve Passive Motion of Toe Joints for Prevention of Pressure Ulcers: A Pilot Study
title_sort system utilizing metal hydride actuators to achieve passive motion of toe joints for prevention of pressure ulcers: a pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350992/
https://www.ncbi.nlm.nih.gov/pubmed/22619724
http://dx.doi.org/10.1155/2012/541383
work_keys_str_mv AT hosonominako asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT inoshuichi asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT satomitsuru asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT yamashitakazuhiko asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT izumitakashi asystemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT hosonominako systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT inoshuichi systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT satomitsuru systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT yamashitakazuhiko systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy
AT izumitakashi systemutilizingmetalhydrideactuatorstoachievepassivemotionoftoejointsforpreventionofpressureulcersapilotstudy