Cargando…

Interpretation of non-invasive breath tests using (13)C-labeled substrates - a preliminary report with (13)C-methacetin

Non-invasive breath tests can serve as valuable diagnostic tools in medicine as they can determine particular enzymatic and metabolic functions in vivo. However, methodological pitfalls have limited the actual clinical application of those tests till today. A major challenge of non-invasive breath t...

Descripción completa

Detalles Bibliográficos
Autores principales: Lock, JF, Taheri, P, Bauer, S, Holzhütter, HG, Malinowski, M, Neuhaus, P, Stockmann, M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3351941/
https://www.ncbi.nlm.nih.gov/pubmed/20149989
http://dx.doi.org/10.1186/2047-783X-14-12-547
_version_ 1782232813935788032
author Lock, JF
Taheri, P
Bauer, S
Holzhütter, HG
Malinowski, M
Neuhaus, P
Stockmann, M
author_facet Lock, JF
Taheri, P
Bauer, S
Holzhütter, HG
Malinowski, M
Neuhaus, P
Stockmann, M
author_sort Lock, JF
collection PubMed
description Non-invasive breath tests can serve as valuable diagnostic tools in medicine as they can determine particular enzymatic and metabolic functions in vivo. However, methodological pitfalls have limited the actual clinical application of those tests till today. A major challenge of non-invasive breath tests has remained the provision of individually reliable test results. To overcome these limitations, a better understanding of breath kinetics during non-invasive breaths tests is essential. This analysis compares the breath recovery of a (13)C-methacetin breath test with the actual serum kinetics of the substrate. It is shown, that breath and serum kinetics of the same test are significantly different over a period of 60 minutes. The recovery of the tracer (13)CO(2 )in breath seems to be significantly delayed due to intermediate storage in the bicarbonate pool. This has to be taken into account for the application of non-invasive breath test protocols. Otherwise, breath tests might display bicarbonate kinetics despite the metabolic capacity of the particular target enzyme.
format Online
Article
Text
id pubmed-3351941
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33519412012-05-16 Interpretation of non-invasive breath tests using (13)C-labeled substrates - a preliminary report with (13)C-methacetin Lock, JF Taheri, P Bauer, S Holzhütter, HG Malinowski, M Neuhaus, P Stockmann, M Eur J Med Res Research Non-invasive breath tests can serve as valuable diagnostic tools in medicine as they can determine particular enzymatic and metabolic functions in vivo. However, methodological pitfalls have limited the actual clinical application of those tests till today. A major challenge of non-invasive breath tests has remained the provision of individually reliable test results. To overcome these limitations, a better understanding of breath kinetics during non-invasive breaths tests is essential. This analysis compares the breath recovery of a (13)C-methacetin breath test with the actual serum kinetics of the substrate. It is shown, that breath and serum kinetics of the same test are significantly different over a period of 60 minutes. The recovery of the tracer (13)CO(2 )in breath seems to be significantly delayed due to intermediate storage in the bicarbonate pool. This has to be taken into account for the application of non-invasive breath test protocols. Otherwise, breath tests might display bicarbonate kinetics despite the metabolic capacity of the particular target enzyme. BioMed Central 2009-12-14 /pmc/articles/PMC3351941/ /pubmed/20149989 http://dx.doi.org/10.1186/2047-783X-14-12-547 Text en Copyright ©2009 I. Holzapfel Publishers
spellingShingle Research
Lock, JF
Taheri, P
Bauer, S
Holzhütter, HG
Malinowski, M
Neuhaus, P
Stockmann, M
Interpretation of non-invasive breath tests using (13)C-labeled substrates - a preliminary report with (13)C-methacetin
title Interpretation of non-invasive breath tests using (13)C-labeled substrates - a preliminary report with (13)C-methacetin
title_full Interpretation of non-invasive breath tests using (13)C-labeled substrates - a preliminary report with (13)C-methacetin
title_fullStr Interpretation of non-invasive breath tests using (13)C-labeled substrates - a preliminary report with (13)C-methacetin
title_full_unstemmed Interpretation of non-invasive breath tests using (13)C-labeled substrates - a preliminary report with (13)C-methacetin
title_short Interpretation of non-invasive breath tests using (13)C-labeled substrates - a preliminary report with (13)C-methacetin
title_sort interpretation of non-invasive breath tests using (13)c-labeled substrates - a preliminary report with (13)c-methacetin
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3351941/
https://www.ncbi.nlm.nih.gov/pubmed/20149989
http://dx.doi.org/10.1186/2047-783X-14-12-547
work_keys_str_mv AT lockjf interpretationofnoninvasivebreathtestsusing13clabeledsubstratesapreliminaryreportwith13cmethacetin
AT taherip interpretationofnoninvasivebreathtestsusing13clabeledsubstratesapreliminaryreportwith13cmethacetin
AT bauers interpretationofnoninvasivebreathtestsusing13clabeledsubstratesapreliminaryreportwith13cmethacetin
AT holzhutterhg interpretationofnoninvasivebreathtestsusing13clabeledsubstratesapreliminaryreportwith13cmethacetin
AT malinowskim interpretationofnoninvasivebreathtestsusing13clabeledsubstratesapreliminaryreportwith13cmethacetin
AT neuhausp interpretationofnoninvasivebreathtestsusing13clabeledsubstratesapreliminaryreportwith13cmethacetin
AT stockmannm interpretationofnoninvasivebreathtestsusing13clabeledsubstratesapreliminaryreportwith13cmethacetin