Mitigation of building-related polychlorinated biphenyls in indoor air of a school
BACKGROUND: Sealants and other building materials sold in the U.S. from 1958 - 1971 were commonly manufactured with polychlorinated biphenyls (PCBs) at percent quantities by weight. Volatilization of PCBs from construction materials has been reported to produce PCB levels in indoor air that exceed h...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3353159/ https://www.ncbi.nlm.nih.gov/pubmed/22490055 http://dx.doi.org/10.1186/1476-069X-11-24 |
_version_ | 1782233000551907328 |
---|---|
author | MacIntosh, David L Minegishi, Taeko Fragala, Matthew A Allen, Joseph G Coghlan, Kevin M Stewart, James H McCarthy, John F |
author_facet | MacIntosh, David L Minegishi, Taeko Fragala, Matthew A Allen, Joseph G Coghlan, Kevin M Stewart, James H McCarthy, John F |
author_sort | MacIntosh, David L |
collection | PubMed |
description | BACKGROUND: Sealants and other building materials sold in the U.S. from 1958 - 1971 were commonly manufactured with polychlorinated biphenyls (PCBs) at percent quantities by weight. Volatilization of PCBs from construction materials has been reported to produce PCB levels in indoor air that exceed health protective guideline values. The discovery of PCBs in indoor air of schools can produce numerous complications including disruption of normal operations and potential risks to health. Understanding the dynamics of building-related PCBs in indoor air is needed to identify effective strategies for managing potential exposures and risks. This paper reports on the efficacy of selected engineering controls implemented to mitigate concentrations of PCBs in indoor air. METHODS: Three interventions (ventilation, contact encapsulation, and physical barriers) were evaluated in an elementary school with PCB-containing caulk and elevated PCB concentrations in indoor air. Fluorescent light ballasts did not contain PCBs. Following implementation of the final intervention, measurements obtained over 14 months were used to assess the efficacy of the mitigation methods over time as well as temporal variability of PCBs in indoor air. RESULTS: Controlling for air exchange rates and temperature, the interventions produced statistically significant (p < 0.05) reductions in concentrations of PCBs in indoor air of the school. The mitigation measures remained effective over the course of the entire follow-up period. After all interventions were implemented, PCB levels in indoor air were associated with indoor temperature. In a "broken-stick" regression model with a node at 20°C, temperature explained 79% of the variability of indoor PCB concentrations over time (p < 0.001). CONCLUSIONS: Increasing outdoor air ventilation, encapsulating caulk, and constructing a physical barrier over the encapsulated material were shown to be effective at reducing exposure concentrations of PCBs in indoor air of a school and also preventing direct contact with PCB caulk. In-place management methods such as these avoid the disruption and higher costs of demolition, disposal and reconstruction required when PCB-containing building materials are removed from a school. Because of the influence of temperature on indoor air PCB levels, risk assessment results based on short-term measurements, e.g., a single day or season, may be erroneous and could lead to sub-optimal allocation of resources. |
format | Online Article Text |
id | pubmed-3353159 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-33531592012-05-16 Mitigation of building-related polychlorinated biphenyls in indoor air of a school MacIntosh, David L Minegishi, Taeko Fragala, Matthew A Allen, Joseph G Coghlan, Kevin M Stewart, James H McCarthy, John F Environ Health Research BACKGROUND: Sealants and other building materials sold in the U.S. from 1958 - 1971 were commonly manufactured with polychlorinated biphenyls (PCBs) at percent quantities by weight. Volatilization of PCBs from construction materials has been reported to produce PCB levels in indoor air that exceed health protective guideline values. The discovery of PCBs in indoor air of schools can produce numerous complications including disruption of normal operations and potential risks to health. Understanding the dynamics of building-related PCBs in indoor air is needed to identify effective strategies for managing potential exposures and risks. This paper reports on the efficacy of selected engineering controls implemented to mitigate concentrations of PCBs in indoor air. METHODS: Three interventions (ventilation, contact encapsulation, and physical barriers) were evaluated in an elementary school with PCB-containing caulk and elevated PCB concentrations in indoor air. Fluorescent light ballasts did not contain PCBs. Following implementation of the final intervention, measurements obtained over 14 months were used to assess the efficacy of the mitigation methods over time as well as temporal variability of PCBs in indoor air. RESULTS: Controlling for air exchange rates and temperature, the interventions produced statistically significant (p < 0.05) reductions in concentrations of PCBs in indoor air of the school. The mitigation measures remained effective over the course of the entire follow-up period. After all interventions were implemented, PCB levels in indoor air were associated with indoor temperature. In a "broken-stick" regression model with a node at 20°C, temperature explained 79% of the variability of indoor PCB concentrations over time (p < 0.001). CONCLUSIONS: Increasing outdoor air ventilation, encapsulating caulk, and constructing a physical barrier over the encapsulated material were shown to be effective at reducing exposure concentrations of PCBs in indoor air of a school and also preventing direct contact with PCB caulk. In-place management methods such as these avoid the disruption and higher costs of demolition, disposal and reconstruction required when PCB-containing building materials are removed from a school. Because of the influence of temperature on indoor air PCB levels, risk assessment results based on short-term measurements, e.g., a single day or season, may be erroneous and could lead to sub-optimal allocation of resources. BioMed Central 2012-04-10 /pmc/articles/PMC3353159/ /pubmed/22490055 http://dx.doi.org/10.1186/1476-069X-11-24 Text en Copyright ©2012 MacIntosh et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research MacIntosh, David L Minegishi, Taeko Fragala, Matthew A Allen, Joseph G Coghlan, Kevin M Stewart, James H McCarthy, John F Mitigation of building-related polychlorinated biphenyls in indoor air of a school |
title | Mitigation of building-related polychlorinated biphenyls in indoor air of a school |
title_full | Mitigation of building-related polychlorinated biphenyls in indoor air of a school |
title_fullStr | Mitigation of building-related polychlorinated biphenyls in indoor air of a school |
title_full_unstemmed | Mitigation of building-related polychlorinated biphenyls in indoor air of a school |
title_short | Mitigation of building-related polychlorinated biphenyls in indoor air of a school |
title_sort | mitigation of building-related polychlorinated biphenyls in indoor air of a school |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3353159/ https://www.ncbi.nlm.nih.gov/pubmed/22490055 http://dx.doi.org/10.1186/1476-069X-11-24 |
work_keys_str_mv | AT macintoshdavidl mitigationofbuildingrelatedpolychlorinatedbiphenylsinindoorairofaschool AT minegishitaeko mitigationofbuildingrelatedpolychlorinatedbiphenylsinindoorairofaschool AT fragalamatthewa mitigationofbuildingrelatedpolychlorinatedbiphenylsinindoorairofaschool AT allenjosephg mitigationofbuildingrelatedpolychlorinatedbiphenylsinindoorairofaschool AT coghlankevinm mitigationofbuildingrelatedpolychlorinatedbiphenylsinindoorairofaschool AT stewartjamesh mitigationofbuildingrelatedpolychlorinatedbiphenylsinindoorairofaschool AT mccarthyjohnf mitigationofbuildingrelatedpolychlorinatedbiphenylsinindoorairofaschool |