Cargando…

Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer

BACKGROUND: Intensity-modulated radiotherapy (IMRT) enables a better conformality to the target while sparing the surrounding normal tissues and potentially allows to increase the dose to the target, if this is precisely and accurately determined. The goal of this work is to determine inter-fraction...

Descripción completa

Detalles Bibliográficos
Autores principales: Palombarini, Marcella, Mengoli, Stefano, Fantazzini, Paola, Cadioli, Cecilia, Degli Esposti, Claudio, Frezza, Giovanni Piero
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3359229/
https://www.ncbi.nlm.nih.gov/pubmed/22472040
http://dx.doi.org/10.1186/1748-717X-7-56
_version_ 1782233840549363712
author Palombarini, Marcella
Mengoli, Stefano
Fantazzini, Paola
Cadioli, Cecilia
Degli Esposti, Claudio
Frezza, Giovanni Piero
author_facet Palombarini, Marcella
Mengoli, Stefano
Fantazzini, Paola
Cadioli, Cecilia
Degli Esposti, Claudio
Frezza, Giovanni Piero
author_sort Palombarini, Marcella
collection PubMed
description BACKGROUND: Intensity-modulated radiotherapy (IMRT) enables a better conformality to the target while sparing the surrounding normal tissues and potentially allows to increase the dose to the target, if this is precisely and accurately determined. The goal of this work is to determine inter-fraction setup errors and prostate motion in IMRT for localized prostate cancer, guided by daily kilovoltage cone beam computed tomography (kVCBCT). METHODS: Systematic and random components of the shifts were retrospectively evaluated by comparing two matching modalities (automatic bone and manual soft-tissue) between each of the 641 daily kVCBCTs (18 patients) and the planning kVCT. A simulated Adaptive Radiation Therapy (ART) protocol using the average of the first 5 kVCBCTs was tested by non-parametric bootstrapping procedure. RESULTS: Shifts were < 1 mm in left-right (LR) and in supero-inferior (SI) direction. In antero-posterior (AP) direction systematic prostate motion (2.7 ± 0.7 mm) gave the major contribution to the variability of results; the averages of the absolute total shifts were significantly larger in anterior (6.3 ± 0.2 mm) than in posterior (3.9 mm ± 0.2 mm) direction. The ART protocol would reduce margins in LR, SI and anterior but not in posterior direction. CONCLUSIONS: The online soft-tissue correction based on daily kVCBCT during IMRT of prostate cancer is fast and efficient. The large random movements of prostate respect to bony anatomy, especially in the AP direction, where anisotropic margins are needed, suggest that daily kVCBCT is at the present time preferable for high dose and high gradients IMRT prostate treatments.
format Online
Article
Text
id pubmed-3359229
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33592292012-05-24 Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer Palombarini, Marcella Mengoli, Stefano Fantazzini, Paola Cadioli, Cecilia Degli Esposti, Claudio Frezza, Giovanni Piero Radiat Oncol Research BACKGROUND: Intensity-modulated radiotherapy (IMRT) enables a better conformality to the target while sparing the surrounding normal tissues and potentially allows to increase the dose to the target, if this is precisely and accurately determined. The goal of this work is to determine inter-fraction setup errors and prostate motion in IMRT for localized prostate cancer, guided by daily kilovoltage cone beam computed tomography (kVCBCT). METHODS: Systematic and random components of the shifts were retrospectively evaluated by comparing two matching modalities (automatic bone and manual soft-tissue) between each of the 641 daily kVCBCTs (18 patients) and the planning kVCT. A simulated Adaptive Radiation Therapy (ART) protocol using the average of the first 5 kVCBCTs was tested by non-parametric bootstrapping procedure. RESULTS: Shifts were < 1 mm in left-right (LR) and in supero-inferior (SI) direction. In antero-posterior (AP) direction systematic prostate motion (2.7 ± 0.7 mm) gave the major contribution to the variability of results; the averages of the absolute total shifts were significantly larger in anterior (6.3 ± 0.2 mm) than in posterior (3.9 mm ± 0.2 mm) direction. The ART protocol would reduce margins in LR, SI and anterior but not in posterior direction. CONCLUSIONS: The online soft-tissue correction based on daily kVCBCT during IMRT of prostate cancer is fast and efficient. The large random movements of prostate respect to bony anatomy, especially in the AP direction, where anisotropic margins are needed, suggest that daily kVCBCT is at the present time preferable for high dose and high gradients IMRT prostate treatments. BioMed Central 2012-04-02 /pmc/articles/PMC3359229/ /pubmed/22472040 http://dx.doi.org/10.1186/1748-717X-7-56 Text en Copyright ©2012 Palombarini et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Palombarini, Marcella
Mengoli, Stefano
Fantazzini, Paola
Cadioli, Cecilia
Degli Esposti, Claudio
Frezza, Giovanni Piero
Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
title Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
title_full Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
title_fullStr Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
title_full_unstemmed Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
title_short Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
title_sort analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3359229/
https://www.ncbi.nlm.nih.gov/pubmed/22472040
http://dx.doi.org/10.1186/1748-717X-7-56
work_keys_str_mv AT palombarinimarcella analysisofinterfractionsetuperrorsandorganmotionbydailykilovoltageconebeamcomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT mengolistefano analysisofinterfractionsetuperrorsandorganmotionbydailykilovoltageconebeamcomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT fantazzinipaola analysisofinterfractionsetuperrorsandorganmotionbydailykilovoltageconebeamcomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT cadiolicecilia analysisofinterfractionsetuperrorsandorganmotionbydailykilovoltageconebeamcomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT degliesposticlaudio analysisofinterfractionsetuperrorsandorganmotionbydailykilovoltageconebeamcomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT frezzagiovannipiero analysisofinterfractionsetuperrorsandorganmotionbydailykilovoltageconebeamcomputedtomographyinintensitymodulatedradiotherapyofprostatecancer