Cargando…

Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry

Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation...

Descripción completa

Detalles Bibliográficos
Autores principales: Zelinková, Hana, Červenka, Rostislav, Komárek, Josef
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Scientific World Journal 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3361235/
https://www.ncbi.nlm.nih.gov/pubmed/22654606
http://dx.doi.org/10.1100/2012/439875
_version_ 1782234104241061888
author Zelinková, Hana
Červenka, Rostislav
Komárek, Josef
author_facet Zelinková, Hana
Červenka, Rostislav
Komárek, Josef
author_sort Zelinková, Hana
collection PubMed
description Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. The calibration solutions had the form of methyl isobutyl ketone (MIBK) extracts or MIBK-methanol solutions with the TMDTC and DEDTC chelates and aqueous solutions with thiourea complexes. The best results were obtained for MIBK-methanol solutions in the presence of 2.5 g L(−1) TMDTC. The surface of graphite platforms for solid sampling was modified with palladium or rhenium by using electrodeposition from a drop of solutions. The Re modifier is preferable due to a higher lifetime of platform coating. A new SS-ETAAS procedure using the direct sampling of solid samples into a platform with an Re modified graphite surface and the calibration against MIBK-methanol solutions in the presence of TMDTC is proposed for the determination of mercury content in solid environmental samples, such as soil and plants.
format Online
Article
Text
id pubmed-3361235
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Scientific World Journal
record_format MEDLINE/PubMed
spelling pubmed-33612352012-05-31 Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry Zelinková, Hana Červenka, Rostislav Komárek, Josef ScientificWorldJournal Research Article Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. The calibration solutions had the form of methyl isobutyl ketone (MIBK) extracts or MIBK-methanol solutions with the TMDTC and DEDTC chelates and aqueous solutions with thiourea complexes. The best results were obtained for MIBK-methanol solutions in the presence of 2.5 g L(−1) TMDTC. The surface of graphite platforms for solid sampling was modified with palladium or rhenium by using electrodeposition from a drop of solutions. The Re modifier is preferable due to a higher lifetime of platform coating. A new SS-ETAAS procedure using the direct sampling of solid samples into a platform with an Re modified graphite surface and the calibration against MIBK-methanol solutions in the presence of TMDTC is proposed for the determination of mercury content in solid environmental samples, such as soil and plants. The Scientific World Journal 2012-04-30 /pmc/articles/PMC3361235/ /pubmed/22654606 http://dx.doi.org/10.1100/2012/439875 Text en Copyright © 2012 Hana Zelinková et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zelinková, Hana
Červenka, Rostislav
Komárek, Josef
Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
title Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
title_full Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
title_fullStr Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
title_full_unstemmed Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
title_short Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
title_sort stabilizing agents for calibration in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3361235/
https://www.ncbi.nlm.nih.gov/pubmed/22654606
http://dx.doi.org/10.1100/2012/439875
work_keys_str_mv AT zelinkovahana stabilizingagentsforcalibrationinthedeterminationofmercuryusingsolidsamplingelectrothermalatomicabsorptionspectrometry
AT cervenkarostislav stabilizingagentsforcalibrationinthedeterminationofmercuryusingsolidsamplingelectrothermalatomicabsorptionspectrometry
AT komarekjosef stabilizingagentsforcalibrationinthedeterminationofmercuryusingsolidsamplingelectrothermalatomicabsorptionspectrometry