Cargando…
Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Scientific World Journal
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3361235/ https://www.ncbi.nlm.nih.gov/pubmed/22654606 http://dx.doi.org/10.1100/2012/439875 |
_version_ | 1782234104241061888 |
---|---|
author | Zelinková, Hana Červenka, Rostislav Komárek, Josef |
author_facet | Zelinková, Hana Červenka, Rostislav Komárek, Josef |
author_sort | Zelinková, Hana |
collection | PubMed |
description | Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. The calibration solutions had the form of methyl isobutyl ketone (MIBK) extracts or MIBK-methanol solutions with the TMDTC and DEDTC chelates and aqueous solutions with thiourea complexes. The best results were obtained for MIBK-methanol solutions in the presence of 2.5 g L(−1) TMDTC. The surface of graphite platforms for solid sampling was modified with palladium or rhenium by using electrodeposition from a drop of solutions. The Re modifier is preferable due to a higher lifetime of platform coating. A new SS-ETAAS procedure using the direct sampling of solid samples into a platform with an Re modified graphite surface and the calibration against MIBK-methanol solutions in the presence of TMDTC is proposed for the determination of mercury content in solid environmental samples, such as soil and plants. |
format | Online Article Text |
id | pubmed-3361235 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Scientific World Journal |
record_format | MEDLINE/PubMed |
spelling | pubmed-33612352012-05-31 Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry Zelinková, Hana Červenka, Rostislav Komárek, Josef ScientificWorldJournal Research Article Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. The calibration solutions had the form of methyl isobutyl ketone (MIBK) extracts or MIBK-methanol solutions with the TMDTC and DEDTC chelates and aqueous solutions with thiourea complexes. The best results were obtained for MIBK-methanol solutions in the presence of 2.5 g L(−1) TMDTC. The surface of graphite platforms for solid sampling was modified with palladium or rhenium by using electrodeposition from a drop of solutions. The Re modifier is preferable due to a higher lifetime of platform coating. A new SS-ETAAS procedure using the direct sampling of solid samples into a platform with an Re modified graphite surface and the calibration against MIBK-methanol solutions in the presence of TMDTC is proposed for the determination of mercury content in solid environmental samples, such as soil and plants. The Scientific World Journal 2012-04-30 /pmc/articles/PMC3361235/ /pubmed/22654606 http://dx.doi.org/10.1100/2012/439875 Text en Copyright © 2012 Hana Zelinková et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zelinková, Hana Červenka, Rostislav Komárek, Josef Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry |
title | Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry |
title_full | Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry |
title_fullStr | Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry |
title_full_unstemmed | Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry |
title_short | Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry |
title_sort | stabilizing agents for calibration in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3361235/ https://www.ncbi.nlm.nih.gov/pubmed/22654606 http://dx.doi.org/10.1100/2012/439875 |
work_keys_str_mv | AT zelinkovahana stabilizingagentsforcalibrationinthedeterminationofmercuryusingsolidsamplingelectrothermalatomicabsorptionspectrometry AT cervenkarostislav stabilizingagentsforcalibrationinthedeterminationofmercuryusingsolidsamplingelectrothermalatomicabsorptionspectrometry AT komarekjosef stabilizingagentsforcalibrationinthedeterminationofmercuryusingsolidsamplingelectrothermalatomicabsorptionspectrometry |