Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age

BACKGROUND: Very low birth weight (VLBW) infants (< 1,500 g) with bronchopulmonary dysplasia (BPD) develop lung damage caused by mechanical ventilation and maturational arrest. We compared functional lung development after discharge from hospital between VLBW infants with and without BPD. METHODS...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmalisch, Gerd, Wilitzki, Silke, Roehr, Charles Christoph, Proquitté, Hans, Bührer, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3362756/
https://www.ncbi.nlm.nih.gov/pubmed/22443188
http://dx.doi.org/10.1186/1471-2431-12-37
_version_ 1782234254018609152
author Schmalisch, Gerd
Wilitzki, Silke
Roehr, Charles Christoph
Proquitté, Hans
Bührer, Christoph
author_facet Schmalisch, Gerd
Wilitzki, Silke
Roehr, Charles Christoph
Proquitté, Hans
Bührer, Christoph
author_sort Schmalisch, Gerd
collection PubMed
description BACKGROUND: Very low birth weight (VLBW) infants (< 1,500 g) with bronchopulmonary dysplasia (BPD) develop lung damage caused by mechanical ventilation and maturational arrest. We compared functional lung development after discharge from hospital between VLBW infants with and without BPD. METHODS: Comprehensive lung function assessment was performed at about 50, 70, and 100 weeks of postmenstrual age in 55 sedated VLBW infants (29 with former BPD [O(2 )supplementation was given at 36 weeks of gestational age] and 26 VLBW infants without BPD [controls]). Mean gestational age (26 vs. 29 weeks), birth weight (815 g vs. 1,125 g), and the proportion of infants requiring mechanical ventilation for ≥7 d (55% vs. 8%), differed significantly between BPD infants and controls. RESULTS: Both body weight and length, determined over time, were persistently lower in former BPD infants compared to controls, but no significant between-group differences were noted in respiratory rate, respiratory or airway resistance, functional residual capacity as determined by body plethysmography (FRC(pleth)), maximal expiratory flow at the FRC (V'max (FRC)), or blood gas (pO(2), pCO(2)) levels. Tidal volume, minute ventilation, respiratory compliance, and FRC determined by SF6 multiple breath washout (representing the lung volume in actual communication with the airways) were significantly lower in former BPD infants compared to controls. However, these differences became non-significant after normalization to body weight. CONCLUSIONS: Although somatic growth and the development of some lung functional parameters lag in former BPD infants, the lung function of such infants appears to develop in line with that of non-BPD infants when a body weight correction is applied. Longitudinal lung function testing of preterm infants after discharge from hospital may help to identify former BPD infants at risk of incomplete recovery of respiratory function; such infants are at risk of later respiratory problems.
format Online
Article
Text
id pubmed-3362756
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33627562012-05-31 Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age Schmalisch, Gerd Wilitzki, Silke Roehr, Charles Christoph Proquitté, Hans Bührer, Christoph BMC Pediatr Research Article BACKGROUND: Very low birth weight (VLBW) infants (< 1,500 g) with bronchopulmonary dysplasia (BPD) develop lung damage caused by mechanical ventilation and maturational arrest. We compared functional lung development after discharge from hospital between VLBW infants with and without BPD. METHODS: Comprehensive lung function assessment was performed at about 50, 70, and 100 weeks of postmenstrual age in 55 sedated VLBW infants (29 with former BPD [O(2 )supplementation was given at 36 weeks of gestational age] and 26 VLBW infants without BPD [controls]). Mean gestational age (26 vs. 29 weeks), birth weight (815 g vs. 1,125 g), and the proportion of infants requiring mechanical ventilation for ≥7 d (55% vs. 8%), differed significantly between BPD infants and controls. RESULTS: Both body weight and length, determined over time, were persistently lower in former BPD infants compared to controls, but no significant between-group differences were noted in respiratory rate, respiratory or airway resistance, functional residual capacity as determined by body plethysmography (FRC(pleth)), maximal expiratory flow at the FRC (V'max (FRC)), or blood gas (pO(2), pCO(2)) levels. Tidal volume, minute ventilation, respiratory compliance, and FRC determined by SF6 multiple breath washout (representing the lung volume in actual communication with the airways) were significantly lower in former BPD infants compared to controls. However, these differences became non-significant after normalization to body weight. CONCLUSIONS: Although somatic growth and the development of some lung functional parameters lag in former BPD infants, the lung function of such infants appears to develop in line with that of non-BPD infants when a body weight correction is applied. Longitudinal lung function testing of preterm infants after discharge from hospital may help to identify former BPD infants at risk of incomplete recovery of respiratory function; such infants are at risk of later respiratory problems. BioMed Central 2012-03-23 /pmc/articles/PMC3362756/ /pubmed/22443188 http://dx.doi.org/10.1186/1471-2431-12-37 Text en Copyright ©2012 Schmalisch et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Schmalisch, Gerd
Wilitzki, Silke
Roehr, Charles Christoph
Proquitté, Hans
Bührer, Christoph
Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age
title Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age
title_full Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age
title_fullStr Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age
title_full_unstemmed Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age
title_short Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age
title_sort development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: longitudinal assessment during the first 15 months of corrected age
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3362756/
https://www.ncbi.nlm.nih.gov/pubmed/22443188
http://dx.doi.org/10.1186/1471-2431-12-37
work_keys_str_mv AT schmalischgerd developmentoflungfunctioninverylowbirthweightinfantswithorwithoutbronchopulmonarydysplasialongitudinalassessmentduringthefirst15monthsofcorrectedage
AT wilitzkisilke developmentoflungfunctioninverylowbirthweightinfantswithorwithoutbronchopulmonarydysplasialongitudinalassessmentduringthefirst15monthsofcorrectedage
AT roehrcharleschristoph developmentoflungfunctioninverylowbirthweightinfantswithorwithoutbronchopulmonarydysplasialongitudinalassessmentduringthefirst15monthsofcorrectedage
AT proquittehans developmentoflungfunctioninverylowbirthweightinfantswithorwithoutbronchopulmonarydysplasialongitudinalassessmentduringthefirst15monthsofcorrectedage
AT buhrerchristoph developmentoflungfunctioninverylowbirthweightinfantswithorwithoutbronchopulmonarydysplasialongitudinalassessmentduringthefirst15monthsofcorrectedage