Cargando…
PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis
This paper presents a theoretical analysis of the maximum contact stress and the lubrication regimes for PEEK (Polyether-ether-ketone) based self-mating cervical total disc arthroplasty. The NuNec(®) cervical disc arthroplasty system was chosen as the study object, which was then analytically modell...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3367298/ https://www.ncbi.nlm.nih.gov/pubmed/22670159 http://dx.doi.org/10.2174/1874230001206010073 |
_version_ | 1782234831863676928 |
---|---|
author | Xin, H Shepherd, DET Dearn, KD |
author_facet | Xin, H Shepherd, DET Dearn, KD |
author_sort | Xin, H |
collection | PubMed |
description | This paper presents a theoretical analysis of the maximum contact stress and the lubrication regimes for PEEK (Polyether-ether-ketone) based self-mating cervical total disc arthroplasty. The NuNec(®) cervical disc arthroplasty system was chosen as the study object, which was then analytically modelled as a ball on socket joint. A non-adhesion Hertzian contact model and elastohydrodynamic lubrication theory were used to predict the maximum contact stress and the minimum film thickness, respectively. The peak contact stress and the minimum film thickness between the bearing surfaces were then determined, as the radial clearance or lubricant was varied. The obtained results show that under 150 N loading, the peak contact stress was in the range 5.9 – 32.1 MPa, well below the yield and fatigue strength of PEEK; the calculated minimum film thickness ranged from 0 to 0.042 µm and the corresponding lambda ratio range was from 0 to 0.052. This indicates that the PEEK based cervical disc arthroplasty will operate under a boundary lubrication regime, within the natural angular velocity range of the cervical spine. |
format | Online Article Text |
id | pubmed-3367298 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Bentham Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-33672982012-06-05 PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis Xin, H Shepherd, DET Dearn, KD Open Biomed Eng J Article This paper presents a theoretical analysis of the maximum contact stress and the lubrication regimes for PEEK (Polyether-ether-ketone) based self-mating cervical total disc arthroplasty. The NuNec(®) cervical disc arthroplasty system was chosen as the study object, which was then analytically modelled as a ball on socket joint. A non-adhesion Hertzian contact model and elastohydrodynamic lubrication theory were used to predict the maximum contact stress and the minimum film thickness, respectively. The peak contact stress and the minimum film thickness between the bearing surfaces were then determined, as the radial clearance or lubricant was varied. The obtained results show that under 150 N loading, the peak contact stress was in the range 5.9 – 32.1 MPa, well below the yield and fatigue strength of PEEK; the calculated minimum film thickness ranged from 0 to 0.042 µm and the corresponding lambda ratio range was from 0 to 0.052. This indicates that the PEEK based cervical disc arthroplasty will operate under a boundary lubrication regime, within the natural angular velocity range of the cervical spine. Bentham Open 2012-05-09 /pmc/articles/PMC3367298/ /pubmed/22670159 http://dx.doi.org/10.2174/1874230001206010073 Text en © Xin et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited. |
spellingShingle | Article Xin, H Shepherd, DET Dearn, KD PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis |
title | PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis |
title_full | PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis |
title_fullStr | PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis |
title_full_unstemmed | PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis |
title_short | PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis |
title_sort | peek (polyether-ether-ketone) based cervical total disc arthroplasty: contact stress and lubrication analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3367298/ https://www.ncbi.nlm.nih.gov/pubmed/22670159 http://dx.doi.org/10.2174/1874230001206010073 |
work_keys_str_mv | AT xinh peekpolyetheretherketonebasedcervicaltotaldiscarthroplastycontactstressandlubricationanalysis AT shepherddet peekpolyetheretherketonebasedcervicaltotaldiscarthroplastycontactstressandlubricationanalysis AT dearnkd peekpolyetheretherketonebasedcervicaltotaldiscarthroplastycontactstressandlubricationanalysis |