Cargando…

Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis

BACKGROUND: SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging...

Descripción completa

Detalles Bibliográficos
Autores principales: Hirschmann, Michael T, Wagner, Christopher R, Rasch, Helmut, Henckel, Johann
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3368747/
https://www.ncbi.nlm.nih.gov/pubmed/22458556
http://dx.doi.org/10.1186/1471-2342-12-5
_version_ 1782234981672681472
author Hirschmann, Michael T
Wagner, Christopher R
Rasch, Helmut
Henckel, Johann
author_facet Hirschmann, Michael T
Wagner, Christopher R
Rasch, Helmut
Henckel, Johann
author_sort Hirschmann, Michael T
collection PubMed
description BACKGROUND: SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging has been recognized in a variety of medical fields and most recently in orthopaedics; however, clinical adoption has been limited due to shortcomings of analytical tools available. Specifically, SPECT analyses are mainly qualitative due to variation in overall metabolic uptake among patients. Furthermore, most analyses are done in 2D, although rich 3D data are available. Consequently, it is difficult to quantitatively compare the position, size, and intensity of SPECT uptake regions among patients, and therefore difficult to draw meaningful clinical conclusions. METHODS: We propose a method for normalizing orthopaedic SPECT/CT data that enables standardised 3D volumetric quantitative measurements and comparison among patients. Our method is based on 3D localisation using clinically relevant anatomical landmarks and frames of reference, along with intensity value normalisation using clinically relevant reference regions. Using the normalised data, we describe a thresholding technique to distinguish clinically relevant hot spots from background activity. RESULTS: Using an exemplar comparison of two patients, we demonstrate how the normalised, 3D-rendered data can provide a richer source of clinical information and allow quantitative comparison of SPECT/CT measurements across patients. Specifically, we demonstrate how non-normalized SPECT/CT analysis can lead to different clinical conclusions than the normalized SPECT/CT analysis, and that normalized quantitative analysis can be a more accurate indicator of pathology. CONCLUSIONS: Conventional orthopaedic frames of reference, 3D volumetric data analysis and thresholding are used to distinguish clinically relevant hot spots from background activity. Our goal is to facilitate a standardised approach to quantitative data collection and comparison of clinical studies using SPECT/CT, enabling more widespread clinical use of this powerful imaging tool.
format Online
Article
Text
id pubmed-3368747
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33687472012-06-07 Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis Hirschmann, Michael T Wagner, Christopher R Rasch, Helmut Henckel, Johann BMC Med Imaging Technical Advance BACKGROUND: SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging has been recognized in a variety of medical fields and most recently in orthopaedics; however, clinical adoption has been limited due to shortcomings of analytical tools available. Specifically, SPECT analyses are mainly qualitative due to variation in overall metabolic uptake among patients. Furthermore, most analyses are done in 2D, although rich 3D data are available. Consequently, it is difficult to quantitatively compare the position, size, and intensity of SPECT uptake regions among patients, and therefore difficult to draw meaningful clinical conclusions. METHODS: We propose a method for normalizing orthopaedic SPECT/CT data that enables standardised 3D volumetric quantitative measurements and comparison among patients. Our method is based on 3D localisation using clinically relevant anatomical landmarks and frames of reference, along with intensity value normalisation using clinically relevant reference regions. Using the normalised data, we describe a thresholding technique to distinguish clinically relevant hot spots from background activity. RESULTS: Using an exemplar comparison of two patients, we demonstrate how the normalised, 3D-rendered data can provide a richer source of clinical information and allow quantitative comparison of SPECT/CT measurements across patients. Specifically, we demonstrate how non-normalized SPECT/CT analysis can lead to different clinical conclusions than the normalized SPECT/CT analysis, and that normalized quantitative analysis can be a more accurate indicator of pathology. CONCLUSIONS: Conventional orthopaedic frames of reference, 3D volumetric data analysis and thresholding are used to distinguish clinically relevant hot spots from background activity. Our goal is to facilitate a standardised approach to quantitative data collection and comparison of clinical studies using SPECT/CT, enabling more widespread clinical use of this powerful imaging tool. BioMed Central 2012-03-29 /pmc/articles/PMC3368747/ /pubmed/22458556 http://dx.doi.org/10.1186/1471-2342-12-5 Text en Copyright ©2012 Hirschmann et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Advance
Hirschmann, Michael T
Wagner, Christopher R
Rasch, Helmut
Henckel, Johann
Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis
title Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis
title_full Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis
title_fullStr Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis
title_full_unstemmed Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis
title_short Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis
title_sort standardized volumetric 3d-analysis of spect/ct imaging in orthopaedics: overcoming the limitations of qualitative 2d analysis
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3368747/
https://www.ncbi.nlm.nih.gov/pubmed/22458556
http://dx.doi.org/10.1186/1471-2342-12-5
work_keys_str_mv AT hirschmannmichaelt standardizedvolumetric3danalysisofspectctimaginginorthopaedicsovercomingthelimitationsofqualitative2danalysis
AT wagnerchristopherr standardizedvolumetric3danalysisofspectctimaginginorthopaedicsovercomingthelimitationsofqualitative2danalysis
AT raschhelmut standardizedvolumetric3danalysisofspectctimaginginorthopaedicsovercomingthelimitationsofqualitative2danalysis
AT henckeljohann standardizedvolumetric3danalysisofspectctimaginginorthopaedicsovercomingthelimitationsofqualitative2danalysis