Cargando…
Hearing Performance Benefits of a Programmable Power Baha® Sound Processor with a Directional Microphone for Patients with a Mixed Hearing Loss
OBJECTIVES: New signal processing technologies have recently become available for Baha® sound processors. These technologies have led to an increase in power and to the implementation of directional microphones. For any new technology, it is important to evaluate the degree of benefit under differen...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Otorhinolaryngology-Head and Neck Surgery
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3369989/ https://www.ncbi.nlm.nih.gov/pubmed/22701154 http://dx.doi.org/10.3342/ceo.2012.5.S1.S76 |
_version_ | 1782235125164015616 |
---|---|
author | Flynn, Mark C. Hedin, Annelen Halvarsson, Glenn Good, Tobias Sadeghi, Andre |
author_facet | Flynn, Mark C. Hedin, Annelen Halvarsson, Glenn Good, Tobias Sadeghi, Andre |
author_sort | Flynn, Mark C. |
collection | PubMed |
description | OBJECTIVES: New signal processing technologies have recently become available for Baha® sound processors. These technologies have led to an increase in power and to the implementation of directional microphones. For any new technology, it is important to evaluate the degree of benefit under different listening situations. METHODS: Twenty wearers of the Baha osseointegrated hearing system participated in the investigation. The control sound processor was the Baha Intenso and the test sound processor was the Cochlear™ Baha® BP110power. Performance was evaluated in terms of free-field audibility with narrow band noise stimuli. Speech recognition of monosyllabic phonetically balanced (PB) words in quiet was performed at three intensity settings (50, 65, and 80 dB sound pressure level [SPL]) with materials presented at 0 degrees azimuth. Speech recognition of sentences in noise using the Hearing in Noise Test (HINT) in an adaptive framework was performed with speech from 0 degrees and noise held constant at 65 dB SPL from 180 degrees. Testing was performed in both the omni and directional microphone settings. Loudness growth was assessed in randomly presented 10 dB steps between 30 and 90 dB SPL to narrow band noise stimuli at 500 Hz and 3,000 Hz. RESULTS: The test sound processor had significantly improved high frequency audibility (3,000-8,000 Hz). Speech recognition of PB words in quiet at three different intensity levels (50, 65, and 80 dB SPL) indicated a significant difference in terms of level (P<0.0001) but not for sound processor type (P>0.05). Speech recognition of sentences in noise demonstrated a 2.5 dB signal-to-noise ratio (SNR) improvement in performance for the test sound processor. The directional microphone provided an additional 2.3 dB SNR improvement in speech recognition (P<0.0001). Loudness growth functions demonstrated similar performance, indicating that both sound processors had sufficient headroom and amplification for the required hearing loss. CONCLUSION: The test sound processor demonstrated significant improvements in the most challenging listening situation (speech recognition in noise). The implementation of a directional microphone demonstrated a further potential improvement in hearing performance. Both the control and test sound processors demonstrated good performance in terms of audibility, word recognition in quiet and loudness growth. |
format | Online Article Text |
id | pubmed-3369989 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Korean Society of Otorhinolaryngology-Head and Neck Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-33699892012-06-13 Hearing Performance Benefits of a Programmable Power Baha® Sound Processor with a Directional Microphone for Patients with a Mixed Hearing Loss Flynn, Mark C. Hedin, Annelen Halvarsson, Glenn Good, Tobias Sadeghi, Andre Clin Exp Otorhinolaryngol Original Article OBJECTIVES: New signal processing technologies have recently become available for Baha® sound processors. These technologies have led to an increase in power and to the implementation of directional microphones. For any new technology, it is important to evaluate the degree of benefit under different listening situations. METHODS: Twenty wearers of the Baha osseointegrated hearing system participated in the investigation. The control sound processor was the Baha Intenso and the test sound processor was the Cochlear™ Baha® BP110power. Performance was evaluated in terms of free-field audibility with narrow band noise stimuli. Speech recognition of monosyllabic phonetically balanced (PB) words in quiet was performed at three intensity settings (50, 65, and 80 dB sound pressure level [SPL]) with materials presented at 0 degrees azimuth. Speech recognition of sentences in noise using the Hearing in Noise Test (HINT) in an adaptive framework was performed with speech from 0 degrees and noise held constant at 65 dB SPL from 180 degrees. Testing was performed in both the omni and directional microphone settings. Loudness growth was assessed in randomly presented 10 dB steps between 30 and 90 dB SPL to narrow band noise stimuli at 500 Hz and 3,000 Hz. RESULTS: The test sound processor had significantly improved high frequency audibility (3,000-8,000 Hz). Speech recognition of PB words in quiet at three different intensity levels (50, 65, and 80 dB SPL) indicated a significant difference in terms of level (P<0.0001) but not for sound processor type (P>0.05). Speech recognition of sentences in noise demonstrated a 2.5 dB signal-to-noise ratio (SNR) improvement in performance for the test sound processor. The directional microphone provided an additional 2.3 dB SNR improvement in speech recognition (P<0.0001). Loudness growth functions demonstrated similar performance, indicating that both sound processors had sufficient headroom and amplification for the required hearing loss. CONCLUSION: The test sound processor demonstrated significant improvements in the most challenging listening situation (speech recognition in noise). The implementation of a directional microphone demonstrated a further potential improvement in hearing performance. Both the control and test sound processors demonstrated good performance in terms of audibility, word recognition in quiet and loudness growth. Korean Society of Otorhinolaryngology-Head and Neck Surgery 2012-04 2012-04-30 /pmc/articles/PMC3369989/ /pubmed/22701154 http://dx.doi.org/10.3342/ceo.2012.5.S1.S76 Text en Copyright © 2012 by Korean Society of Otorhinolaryngology-Head and Neck Surgery. http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Flynn, Mark C. Hedin, Annelen Halvarsson, Glenn Good, Tobias Sadeghi, Andre Hearing Performance Benefits of a Programmable Power Baha® Sound Processor with a Directional Microphone for Patients with a Mixed Hearing Loss |
title | Hearing Performance Benefits of a Programmable Power Baha® Sound Processor with a Directional Microphone for Patients with a Mixed Hearing Loss |
title_full | Hearing Performance Benefits of a Programmable Power Baha® Sound Processor with a Directional Microphone for Patients with a Mixed Hearing Loss |
title_fullStr | Hearing Performance Benefits of a Programmable Power Baha® Sound Processor with a Directional Microphone for Patients with a Mixed Hearing Loss |
title_full_unstemmed | Hearing Performance Benefits of a Programmable Power Baha® Sound Processor with a Directional Microphone for Patients with a Mixed Hearing Loss |
title_short | Hearing Performance Benefits of a Programmable Power Baha® Sound Processor with a Directional Microphone for Patients with a Mixed Hearing Loss |
title_sort | hearing performance benefits of a programmable power baha® sound processor with a directional microphone for patients with a mixed hearing loss |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3369989/ https://www.ncbi.nlm.nih.gov/pubmed/22701154 http://dx.doi.org/10.3342/ceo.2012.5.S1.S76 |
work_keys_str_mv | AT flynnmarkc hearingperformancebenefitsofaprogrammablepowerbahasoundprocessorwithadirectionalmicrophoneforpatientswithamixedhearingloss AT hedinannelen hearingperformancebenefitsofaprogrammablepowerbahasoundprocessorwithadirectionalmicrophoneforpatientswithamixedhearingloss AT halvarssonglenn hearingperformancebenefitsofaprogrammablepowerbahasoundprocessorwithadirectionalmicrophoneforpatientswithamixedhearingloss AT goodtobias hearingperformancebenefitsofaprogrammablepowerbahasoundprocessorwithadirectionalmicrophoneforpatientswithamixedhearingloss AT sadeghiandre hearingperformancebenefitsofaprogrammablepowerbahasoundprocessorwithadirectionalmicrophoneforpatientswithamixedhearingloss |