Cargando…
Reflectance confocal microscopy of optical phantoms
A reflectance confocal scanning laser microscope (rCSLM) operating at 488-nm wavelength imaged three types of optical phantoms: (1) 100-nm-dia. polystyrene microspheres in gel at 2% volume fraction, (2) solid polyurethane phantoms (INO Biomimic(TM)), and (3) common reflectance standards (Spectralon(...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3370959/ https://www.ncbi.nlm.nih.gov/pubmed/22741065 http://dx.doi.org/10.1364/BOE.3.001162 |
_version_ | 1782235153033068544 |
---|---|
author | Jacques, Steven L. Wang, Bo Samatham, Ravikant |
author_facet | Jacques, Steven L. Wang, Bo Samatham, Ravikant |
author_sort | Jacques, Steven L. |
collection | PubMed |
description | A reflectance confocal scanning laser microscope (rCSLM) operating at 488-nm wavelength imaged three types of optical phantoms: (1) 100-nm-dia. polystyrene microspheres in gel at 2% volume fraction, (2) solid polyurethane phantoms (INO Biomimic(TM)), and (3) common reflectance standards (Spectralon(TM)). The noninvasive method measured the exponential decay of reflected signal as the focus (z(f)) moved deeper into the material. The two experimental values, the attenuation coefficient μ and the pre-exponential factor ρ, were mapped into the material optical scattering properties, the scattering coefficient μ(s) and the anisotropy of scattering g. Results show that μ(s) varies as 58, 8–24, and 130–200 cm(-1) for phantom types (1), (2) and (3), respectively. The g varies as 0.112, 0.53–0.67, and 0.003–0.26, respectively. |
format | Online Article Text |
id | pubmed-3370959 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-33709592012-06-27 Reflectance confocal microscopy of optical phantoms Jacques, Steven L. Wang, Bo Samatham, Ravikant Biomed Opt Express Calibration, Validation and Phantom Studies A reflectance confocal scanning laser microscope (rCSLM) operating at 488-nm wavelength imaged three types of optical phantoms: (1) 100-nm-dia. polystyrene microspheres in gel at 2% volume fraction, (2) solid polyurethane phantoms (INO Biomimic(TM)), and (3) common reflectance standards (Spectralon(TM)). The noninvasive method measured the exponential decay of reflected signal as the focus (z(f)) moved deeper into the material. The two experimental values, the attenuation coefficient μ and the pre-exponential factor ρ, were mapped into the material optical scattering properties, the scattering coefficient μ(s) and the anisotropy of scattering g. Results show that μ(s) varies as 58, 8–24, and 130–200 cm(-1) for phantom types (1), (2) and (3), respectively. The g varies as 0.112, 0.53–0.67, and 0.003–0.26, respectively. Optical Society of America 2012-05-01 /pmc/articles/PMC3370959/ /pubmed/22741065 http://dx.doi.org/10.1364/BOE.3.001162 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Calibration, Validation and Phantom Studies Jacques, Steven L. Wang, Bo Samatham, Ravikant Reflectance confocal microscopy of optical phantoms |
title | Reflectance confocal microscopy of optical phantoms |
title_full | Reflectance confocal microscopy of optical phantoms |
title_fullStr | Reflectance confocal microscopy of optical phantoms |
title_full_unstemmed | Reflectance confocal microscopy of optical phantoms |
title_short | Reflectance confocal microscopy of optical phantoms |
title_sort | reflectance confocal microscopy of optical phantoms |
topic | Calibration, Validation and Phantom Studies |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3370959/ https://www.ncbi.nlm.nih.gov/pubmed/22741065 http://dx.doi.org/10.1364/BOE.3.001162 |
work_keys_str_mv | AT jacquesstevenl reflectanceconfocalmicroscopyofopticalphantoms AT wangbo reflectanceconfocalmicroscopyofopticalphantoms AT samathamravikant reflectanceconfocalmicroscopyofopticalphantoms |