Cargando…

Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy

A real-time three-dimensional (3D) photoacoustic imaging system was developed for epilepsy imaging in small animals. The system is based on a spherical array containing 192 transducers with a 5 MHz central frequency. The signals from the 192 transducers are amplified by 16 homemade preamplifier boar...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Bo, Xiang, Liangzhong, Jiang, Max S., Yang, Jianjun, Zhang, Qizhi, Carney, Paul R., Jiang, Huabei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3370981/
https://www.ncbi.nlm.nih.gov/pubmed/22741087
http://dx.doi.org/10.1364/BOE.3.001427
_version_ 1782235158025338880
author Wang, Bo
Xiang, Liangzhong
Jiang, Max S.
Yang, Jianjun
Zhang, Qizhi
Carney, Paul R.
Jiang, Huabei
author_facet Wang, Bo
Xiang, Liangzhong
Jiang, Max S.
Yang, Jianjun
Zhang, Qizhi
Carney, Paul R.
Jiang, Huabei
author_sort Wang, Bo
collection PubMed
description A real-time three-dimensional (3D) photoacoustic imaging system was developed for epilepsy imaging in small animals. The system is based on a spherical array containing 192 transducers with a 5 MHz central frequency. The signals from the 192 transducers are amplified by 16 homemade preamplifier boards with 26 dB and multiplexed into a 64 channel data acquisition system. It can record a complete set of 3D data at a frame rate of 3.3 f/s, and the spatial resolution is about 0.2 mm. Phantom experiments were conducted to demonstrate the high imaging quality and real time imaging ability of the system. Finally, we tested the system on an acute epilepsy rat model, and the induced seizure focus was successfully detected using this system.
format Online
Article
Text
id pubmed-3370981
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-33709812012-06-27 Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy Wang, Bo Xiang, Liangzhong Jiang, Max S. Yang, Jianjun Zhang, Qizhi Carney, Paul R. Jiang, Huabei Biomed Opt Express Photoacoustic Imaging and Spectroscopy A real-time three-dimensional (3D) photoacoustic imaging system was developed for epilepsy imaging in small animals. The system is based on a spherical array containing 192 transducers with a 5 MHz central frequency. The signals from the 192 transducers are amplified by 16 homemade preamplifier boards with 26 dB and multiplexed into a 64 channel data acquisition system. It can record a complete set of 3D data at a frame rate of 3.3 f/s, and the spatial resolution is about 0.2 mm. Phantom experiments were conducted to demonstrate the high imaging quality and real time imaging ability of the system. Finally, we tested the system on an acute epilepsy rat model, and the induced seizure focus was successfully detected using this system. Optical Society of America 2012-05-17 /pmc/articles/PMC3370981/ /pubmed/22741087 http://dx.doi.org/10.1364/BOE.3.001427 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Photoacoustic Imaging and Spectroscopy
Wang, Bo
Xiang, Liangzhong
Jiang, Max S.
Yang, Jianjun
Zhang, Qizhi
Carney, Paul R.
Jiang, Huabei
Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
title Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
title_full Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
title_fullStr Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
title_full_unstemmed Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
title_short Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
title_sort photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
topic Photoacoustic Imaging and Spectroscopy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3370981/
https://www.ncbi.nlm.nih.gov/pubmed/22741087
http://dx.doi.org/10.1364/BOE.3.001427
work_keys_str_mv AT wangbo photoacoustictomographysystemfornoninvasiverealtimethreedimensionalimagingofepilepsy
AT xiangliangzhong photoacoustictomographysystemfornoninvasiverealtimethreedimensionalimagingofepilepsy
AT jiangmaxs photoacoustictomographysystemfornoninvasiverealtimethreedimensionalimagingofepilepsy
AT yangjianjun photoacoustictomographysystemfornoninvasiverealtimethreedimensionalimagingofepilepsy
AT zhangqizhi photoacoustictomographysystemfornoninvasiverealtimethreedimensionalimagingofepilepsy
AT carneypaulr photoacoustictomographysystemfornoninvasiverealtimethreedimensionalimagingofepilepsy
AT jianghuabei photoacoustictomographysystemfornoninvasiverealtimethreedimensionalimagingofepilepsy