Cargando…
Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging
Two-photon fluorescence microscopy has become an indispensable tool for imaging scattering biological samples by detecting scattered fluorescence photons generated from a spatially confined excitation volume. However, this optical sectioning capability breaks down eventually when imaging much deeper...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3370985/ https://www.ncbi.nlm.nih.gov/pubmed/22741091 http://dx.doi.org/10.1364/BOE.3.001465 |
_version_ | 1782235158937600000 |
---|---|
author | Wei, Lu Chen, Zhixing Min, Wei |
author_facet | Wei, Lu Chen, Zhixing Min, Wei |
author_sort | Wei, Lu |
collection | PubMed |
description | Two-photon fluorescence microscopy has become an indispensable tool for imaging scattering biological samples by detecting scattered fluorescence photons generated from a spatially confined excitation volume. However, this optical sectioning capability breaks down eventually when imaging much deeper, as the out-of-focus fluorescence gradually overwhelms the in-focal signal in the scattering samples. The resulting loss of image contrast defines a fundamental imaging-depth limit, which cannot be overcome by increasing excitation efficiency. Herein we propose to extend this depth limit by performing stimulated emission reduced fluorescence (SERF) microscopy in which the two-photon excited fluorescence at the focus is preferentially switched on and off by a modulated and focused laser beam that is capable of inducing stimulated emission of the fluorophores from the excited states. The resulting image, constructed from the reduced fluorescence signal, is found to exhibit a significantly improved signal-to-background contrast owing to its overall higher-order nonlinear dependence on the incident laser intensity. We demonstrate this new concept by both analytical theory and numerical simulations. For brain tissues, SERF is expected to extend the imaging depth limit of two-photon fluorescence microscopy by a factor of more than 1.8. |
format | Online Article Text |
id | pubmed-3370985 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-33709852012-06-27 Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging Wei, Lu Chen, Zhixing Min, Wei Biomed Opt Express Microscopy Two-photon fluorescence microscopy has become an indispensable tool for imaging scattering biological samples by detecting scattered fluorescence photons generated from a spatially confined excitation volume. However, this optical sectioning capability breaks down eventually when imaging much deeper, as the out-of-focus fluorescence gradually overwhelms the in-focal signal in the scattering samples. The resulting loss of image contrast defines a fundamental imaging-depth limit, which cannot be overcome by increasing excitation efficiency. Herein we propose to extend this depth limit by performing stimulated emission reduced fluorescence (SERF) microscopy in which the two-photon excited fluorescence at the focus is preferentially switched on and off by a modulated and focused laser beam that is capable of inducing stimulated emission of the fluorophores from the excited states. The resulting image, constructed from the reduced fluorescence signal, is found to exhibit a significantly improved signal-to-background contrast owing to its overall higher-order nonlinear dependence on the incident laser intensity. We demonstrate this new concept by both analytical theory and numerical simulations. For brain tissues, SERF is expected to extend the imaging depth limit of two-photon fluorescence microscopy by a factor of more than 1.8. Optical Society of America 2012-05-22 /pmc/articles/PMC3370985/ /pubmed/22741091 http://dx.doi.org/10.1364/BOE.3.001465 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Microscopy Wei, Lu Chen, Zhixing Min, Wei Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging |
title | Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging |
title_full | Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging |
title_fullStr | Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging |
title_full_unstemmed | Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging |
title_short | Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging |
title_sort | stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging |
topic | Microscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3370985/ https://www.ncbi.nlm.nih.gov/pubmed/22741091 http://dx.doi.org/10.1364/BOE.3.001465 |
work_keys_str_mv | AT weilu stimulatedemissionreducedfluorescencemicroscopyaconceptforextendingthefundamentaldepthlimitoftwophotonfluorescenceimaging AT chenzhixing stimulatedemissionreducedfluorescencemicroscopyaconceptforextendingthefundamentaldepthlimitoftwophotonfluorescenceimaging AT minwei stimulatedemissionreducedfluorescencemicroscopyaconceptforextendingthefundamentaldepthlimitoftwophotonfluorescenceimaging |