Cargando…
Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form
A new isocratic reversed-phase HPLC method with diode-array UV detection was developed and validated for the determination of methamphetamine and propranolol in tablet dosage forms. Chromatography was carried out on an XTerra RP18 (150×4.6 mm, 5 μm) column using 50 mM pyrrolidine (pH 11.5) – acetoni...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3374560/ https://www.ncbi.nlm.nih.gov/pubmed/22707828 http://dx.doi.org/10.4103/0250-474X.95632 |
_version_ | 1782235663017443328 |
---|---|
author | Shabir, G. A. |
author_facet | Shabir, G. A. |
author_sort | Shabir, G. A. |
collection | PubMed |
description | A new isocratic reversed-phase HPLC method with diode-array UV detection was developed and validated for the determination of methamphetamine and propranolol in tablet dosage forms. Chromatography was carried out on an XTerra RP18 (150×4.6 mm, 5 μm) column using 50 mM pyrrolidine (pH 11.5) – acetonitrile (50:50, v/v) as mobile phase at a flow rate of 1 ml/min. Spectrophotometric detection was performed at a wavelength of 214 nm. The linearity was established over the concentration range of 0.075-0.60 mg/ml for both drugs. The correlation coefficients (r(2)) were ≥0.9998 in each case. The relative standard deviation values for intermediate precision studies were <1%. Statistical analysis of the data showed that the method was precise, accurate, reproducible and selective for the analysis of methamphetamine and propranolol drugs. The method was successfully employed for the determination of propranolol and methamphetamine in commercially available tablet dosage form. |
format | Online Article Text |
id | pubmed-3374560 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-33745602012-06-15 Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form Shabir, G. A. Indian J Pharm Sci Research Paper A new isocratic reversed-phase HPLC method with diode-array UV detection was developed and validated for the determination of methamphetamine and propranolol in tablet dosage forms. Chromatography was carried out on an XTerra RP18 (150×4.6 mm, 5 μm) column using 50 mM pyrrolidine (pH 11.5) – acetonitrile (50:50, v/v) as mobile phase at a flow rate of 1 ml/min. Spectrophotometric detection was performed at a wavelength of 214 nm. The linearity was established over the concentration range of 0.075-0.60 mg/ml for both drugs. The correlation coefficients (r(2)) were ≥0.9998 in each case. The relative standard deviation values for intermediate precision studies were <1%. Statistical analysis of the data showed that the method was precise, accurate, reproducible and selective for the analysis of methamphetamine and propranolol drugs. The method was successfully employed for the determination of propranolol and methamphetamine in commercially available tablet dosage form. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3374560/ /pubmed/22707828 http://dx.doi.org/10.4103/0250-474X.95632 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Paper Shabir, G. A. Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form |
title | Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form |
title_full | Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form |
title_fullStr | Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form |
title_full_unstemmed | Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form |
title_short | Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form |
title_sort | development and validation of rp-hplc method for the determination of methamphetamine and propranolol in tablet dosage form |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3374560/ https://www.ncbi.nlm.nih.gov/pubmed/22707828 http://dx.doi.org/10.4103/0250-474X.95632 |
work_keys_str_mv | AT shabirga developmentandvalidationofrphplcmethodforthedeterminationofmethamphetamineandpropranololintabletdosageform |