A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study

A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating HPLC assay method was developed and validated for determination of Aripiprazole in bulk and solid pharmaceutical dosage form. A reversed-phase C8 (250×4.0 mm, 5 μm particle size) column for HPLC and C8 (50×2.1mm, 1.7...

Descripción completa

Detalles Bibliográficos
Autores principales: Thakkar, R. S., Saravaia, H. T., Ambasana, M. A., Kaila, H. O., Shah, A. K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3374562/
https://www.ncbi.nlm.nih.gov/pubmed/22707830
http://dx.doi.org/10.4103/0250-474X.95638
_version_ 1782235663473573888
author Thakkar, R. S.
Saravaia, H. T.
Ambasana, M. A.
Kaila, H. O.
Shah, A. K.
author_facet Thakkar, R. S.
Saravaia, H. T.
Ambasana, M. A.
Kaila, H. O.
Shah, A. K.
author_sort Thakkar, R. S.
collection PubMed
description A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating HPLC assay method was developed and validated for determination of Aripiprazole in bulk and solid pharmaceutical dosage form. A reversed-phase C8 (250×4.0 mm, 5 μm particle size) column for HPLC and C8 (50×2.1mm, 1.7 μm particle size) for UPLC method in isocratic mode was used. The mobile phase consists of acetonitrile: 20 mM ammonium acetate (90:10, v/v), flow rate was set at 1.0 ml/min and 0.250 ml/min for HPLC and UPLC, respectively and the detection was performed for both methods were at 240 nm. Further the validation of both developed method was performed and subsequently compared to prove its better applicability.
format Online
Article
Text
id pubmed-3374562
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-33745622012-06-15 A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study Thakkar, R. S. Saravaia, H. T. Ambasana, M. A. Kaila, H. O. Shah, A. K. Indian J Pharm Sci Short Communication A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating HPLC assay method was developed and validated for determination of Aripiprazole in bulk and solid pharmaceutical dosage form. A reversed-phase C8 (250×4.0 mm, 5 μm particle size) column for HPLC and C8 (50×2.1mm, 1.7 μm particle size) for UPLC method in isocratic mode was used. The mobile phase consists of acetonitrile: 20 mM ammonium acetate (90:10, v/v), flow rate was set at 1.0 ml/min and 0.250 ml/min for HPLC and UPLC, respectively and the detection was performed for both methods were at 240 nm. Further the validation of both developed method was performed and subsequently compared to prove its better applicability. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3374562/ /pubmed/22707830 http://dx.doi.org/10.4103/0250-474X.95638 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Communication
Thakkar, R. S.
Saravaia, H. T.
Ambasana, M. A.
Kaila, H. O.
Shah, A. K.
A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study
title A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study
title_full A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study
title_fullStr A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study
title_full_unstemmed A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study
title_short A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study
title_sort chromatographic determination of aripiprazole using hplc and uplc: a comparative validation study
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3374562/
https://www.ncbi.nlm.nih.gov/pubmed/22707830
http://dx.doi.org/10.4103/0250-474X.95638
work_keys_str_mv AT thakkarrs achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT saravaiaht achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT ambasanama achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT kailaho achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT shahak achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT thakkarrs chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT saravaiaht chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT ambasanama chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT kailaho chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy
AT shahak chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy