A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study
A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating HPLC assay method was developed and validated for determination of Aripiprazole in bulk and solid pharmaceutical dosage form. A reversed-phase C8 (250×4.0 mm, 5 μm particle size) column for HPLC and C8 (50×2.1mm, 1.7...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3374562/ https://www.ncbi.nlm.nih.gov/pubmed/22707830 http://dx.doi.org/10.4103/0250-474X.95638 |
_version_ | 1782235663473573888 |
---|---|
author | Thakkar, R. S. Saravaia, H. T. Ambasana, M. A. Kaila, H. O. Shah, A. K. |
author_facet | Thakkar, R. S. Saravaia, H. T. Ambasana, M. A. Kaila, H. O. Shah, A. K. |
author_sort | Thakkar, R. S. |
collection | PubMed |
description | A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating HPLC assay method was developed and validated for determination of Aripiprazole in bulk and solid pharmaceutical dosage form. A reversed-phase C8 (250×4.0 mm, 5 μm particle size) column for HPLC and C8 (50×2.1mm, 1.7 μm particle size) for UPLC method in isocratic mode was used. The mobile phase consists of acetonitrile: 20 mM ammonium acetate (90:10, v/v), flow rate was set at 1.0 ml/min and 0.250 ml/min for HPLC and UPLC, respectively and the detection was performed for both methods were at 240 nm. Further the validation of both developed method was performed and subsequently compared to prove its better applicability. |
format | Online Article Text |
id | pubmed-3374562 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-33745622012-06-15 A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study Thakkar, R. S. Saravaia, H. T. Ambasana, M. A. Kaila, H. O. Shah, A. K. Indian J Pharm Sci Short Communication A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating HPLC assay method was developed and validated for determination of Aripiprazole in bulk and solid pharmaceutical dosage form. A reversed-phase C8 (250×4.0 mm, 5 μm particle size) column for HPLC and C8 (50×2.1mm, 1.7 μm particle size) for UPLC method in isocratic mode was used. The mobile phase consists of acetonitrile: 20 mM ammonium acetate (90:10, v/v), flow rate was set at 1.0 ml/min and 0.250 ml/min for HPLC and UPLC, respectively and the detection was performed for both methods were at 240 nm. Further the validation of both developed method was performed and subsequently compared to prove its better applicability. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3374562/ /pubmed/22707830 http://dx.doi.org/10.4103/0250-474X.95638 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Communication Thakkar, R. S. Saravaia, H. T. Ambasana, M. A. Kaila, H. O. Shah, A. K. A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study |
title | A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study |
title_full | A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study |
title_fullStr | A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study |
title_full_unstemmed | A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study |
title_short | A Chromatographic Determination of Aripiprazole using HPLC and UPLC: A Comparative Validation Study |
title_sort | chromatographic determination of aripiprazole using hplc and uplc: a comparative validation study |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3374562/ https://www.ncbi.nlm.nih.gov/pubmed/22707830 http://dx.doi.org/10.4103/0250-474X.95638 |
work_keys_str_mv | AT thakkarrs achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT saravaiaht achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT ambasanama achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT kailaho achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT shahak achromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT thakkarrs chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT saravaiaht chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT ambasanama chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT kailaho chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy AT shahak chromatographicdeterminationofaripiprazoleusinghplcanduplcacomparativevalidationstudy |