Cargando…

Test-Retest Reliability and Physiological Responses Associated with the Steep Ramp Anaerobic Test in Patients with COPD

The Steep Ramp Anaerobic Test (SRAT) was developed as a clinical test of anaerobic leg muscle function for use in determining anaerobic power and in prescribing high-intensity interval exercise in patients with chronic heart failure and Chronic Obstructive Pulmonary Disease (COPD); however, neither...

Descripción completa

Detalles Bibliográficos
Autores principales: Chura, Robyn L., Marciniuk, Darcy D., Clemens, Ron, Butcher, Scotty J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3375098/
https://www.ncbi.nlm.nih.gov/pubmed/22720154
http://dx.doi.org/10.1155/2012/653831
_version_ 1782235714617868288
author Chura, Robyn L.
Marciniuk, Darcy D.
Clemens, Ron
Butcher, Scotty J.
author_facet Chura, Robyn L.
Marciniuk, Darcy D.
Clemens, Ron
Butcher, Scotty J.
author_sort Chura, Robyn L.
collection PubMed
description The Steep Ramp Anaerobic Test (SRAT) was developed as a clinical test of anaerobic leg muscle function for use in determining anaerobic power and in prescribing high-intensity interval exercise in patients with chronic heart failure and Chronic Obstructive Pulmonary Disease (COPD); however, neither the test-retest reliability nor the physiological qualities of this test have been reported. We therefore, assessed test-retest reliability of the SRAT and the physiological characteristics associated with the test in patients with COPD. 11 COPD patients (mean FEV(1) 43% predicted) performed a cardiopulmonary exercise test (CPET) on Day 1, and an SRAT and a 30-second Wingate anaerobic test (WAT) on each of Days 2 and 3. The SRAT showed a high degree of test-retest reliability (ICC = 0.99; CV = 3.8%, and bias 4.5 W, error −15.3–24.4 W). Power output on the SRAT was 157 W compared to 66 W on the CPET and 231 W on the WAT. Despite the differences in workload, patients exhibited similar metabolic and ventilatory responses between the three tests. Measures of ventilatory constraint correlated more strongly with the CPET than the WAT; however, physiological variables correlated more strongly with the WAT. The SRAT is a highly reliable test that better reflects physiological performance on a WAT power test despite a similar level of ventilatory constraint compared to CPET.
format Online
Article
Text
id pubmed-3375098
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33750982012-06-20 Test-Retest Reliability and Physiological Responses Associated with the Steep Ramp Anaerobic Test in Patients with COPD Chura, Robyn L. Marciniuk, Darcy D. Clemens, Ron Butcher, Scotty J. Pulm Med Research Article The Steep Ramp Anaerobic Test (SRAT) was developed as a clinical test of anaerobic leg muscle function for use in determining anaerobic power and in prescribing high-intensity interval exercise in patients with chronic heart failure and Chronic Obstructive Pulmonary Disease (COPD); however, neither the test-retest reliability nor the physiological qualities of this test have been reported. We therefore, assessed test-retest reliability of the SRAT and the physiological characteristics associated with the test in patients with COPD. 11 COPD patients (mean FEV(1) 43% predicted) performed a cardiopulmonary exercise test (CPET) on Day 1, and an SRAT and a 30-second Wingate anaerobic test (WAT) on each of Days 2 and 3. The SRAT showed a high degree of test-retest reliability (ICC = 0.99; CV = 3.8%, and bias 4.5 W, error −15.3–24.4 W). Power output on the SRAT was 157 W compared to 66 W on the CPET and 231 W on the WAT. Despite the differences in workload, patients exhibited similar metabolic and ventilatory responses between the three tests. Measures of ventilatory constraint correlated more strongly with the CPET than the WAT; however, physiological variables correlated more strongly with the WAT. The SRAT is a highly reliable test that better reflects physiological performance on a WAT power test despite a similar level of ventilatory constraint compared to CPET. Hindawi Publishing Corporation 2012 2012-06-06 /pmc/articles/PMC3375098/ /pubmed/22720154 http://dx.doi.org/10.1155/2012/653831 Text en Copyright © 2012 Robyn L. Chura et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chura, Robyn L.
Marciniuk, Darcy D.
Clemens, Ron
Butcher, Scotty J.
Test-Retest Reliability and Physiological Responses Associated with the Steep Ramp Anaerobic Test in Patients with COPD
title Test-Retest Reliability and Physiological Responses Associated with the Steep Ramp Anaerobic Test in Patients with COPD
title_full Test-Retest Reliability and Physiological Responses Associated with the Steep Ramp Anaerobic Test in Patients with COPD
title_fullStr Test-Retest Reliability and Physiological Responses Associated with the Steep Ramp Anaerobic Test in Patients with COPD
title_full_unstemmed Test-Retest Reliability and Physiological Responses Associated with the Steep Ramp Anaerobic Test in Patients with COPD
title_short Test-Retest Reliability and Physiological Responses Associated with the Steep Ramp Anaerobic Test in Patients with COPD
title_sort test-retest reliability and physiological responses associated with the steep ramp anaerobic test in patients with copd
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3375098/
https://www.ncbi.nlm.nih.gov/pubmed/22720154
http://dx.doi.org/10.1155/2012/653831
work_keys_str_mv AT churarobynl testretestreliabilityandphysiologicalresponsesassociatedwiththesteeprampanaerobictestinpatientswithcopd
AT marciniukdarcyd testretestreliabilityandphysiologicalresponsesassociatedwiththesteeprampanaerobictestinpatientswithcopd
AT clemensron testretestreliabilityandphysiologicalresponsesassociatedwiththesteeprampanaerobictestinpatientswithcopd
AT butcherscottyj testretestreliabilityandphysiologicalresponsesassociatedwiththesteeprampanaerobictestinpatientswithcopd