A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
Here, we report the application of a label-free electrochemical aptasensor based on a graphite-epoxy composite electrode for the detection of thrombin; in this work, aptamers were immobilized onto the electrodes surface using wet physical adsorption. The detection principle is based on the changes o...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3376577/ https://www.ncbi.nlm.nih.gov/pubmed/22736991 http://dx.doi.org/10.3390/s120303037 |
_version_ | 1782235846065258496 |
---|---|
author | Ocaña, Cristina Pacios, Mercè del Valle, Manel |
author_facet | Ocaña, Cristina Pacios, Mercè del Valle, Manel |
author_sort | Ocaña, Cristina |
collection | PubMed |
description | Here, we report the application of a label-free electrochemical aptasensor based on a graphite-epoxy composite electrode for the detection of thrombin; in this work, aptamers were immobilized onto the electrodes surface using wet physical adsorption. The detection principle is based on the changes of the interfacial properties of the electrode; these were probed in the presence of the reversible redox couple [Fe(CN)(6)](3−)/[Fe(CN)(6)](4−) using impedance measurements. The electrode surface was partially blocked due to formation of aptamer-thrombin complex, resulting in an increase of the interfacial electron-transfer resistance detected by Electrochemical Impedance Spectroscopy (EIS). The aptasensor showed a linear response for thrombin in the range of 7.5 pM to 75 pM and a detection limit of 4.5 pM. The aptasensor was regenerated by breaking the complex formed between the aptamer and thrombin using 2.0 M NaCl solution at 42 °C, showing its operation for different cycles. The interference response caused by main proteins in serum has been characterized. |
format | Online Article Text |
id | pubmed-3376577 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-33765772012-06-25 A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode Ocaña, Cristina Pacios, Mercè del Valle, Manel Sensors (Basel) Article Here, we report the application of a label-free electrochemical aptasensor based on a graphite-epoxy composite electrode for the detection of thrombin; in this work, aptamers were immobilized onto the electrodes surface using wet physical adsorption. The detection principle is based on the changes of the interfacial properties of the electrode; these were probed in the presence of the reversible redox couple [Fe(CN)(6)](3−)/[Fe(CN)(6)](4−) using impedance measurements. The electrode surface was partially blocked due to formation of aptamer-thrombin complex, resulting in an increase of the interfacial electron-transfer resistance detected by Electrochemical Impedance Spectroscopy (EIS). The aptasensor showed a linear response for thrombin in the range of 7.5 pM to 75 pM and a detection limit of 4.5 pM. The aptasensor was regenerated by breaking the complex formed between the aptamer and thrombin using 2.0 M NaCl solution at 42 °C, showing its operation for different cycles. The interference response caused by main proteins in serum has been characterized. Molecular Diversity Preservation International (MDPI) 2012-03-06 /pmc/articles/PMC3376577/ /pubmed/22736991 http://dx.doi.org/10.3390/s120303037 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Ocaña, Cristina Pacios, Mercè del Valle, Manel A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode |
title | A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode |
title_full | A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode |
title_fullStr | A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode |
title_full_unstemmed | A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode |
title_short | A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode |
title_sort | reusable impedimetric aptasensor for detection of thrombin employing a graphite-epoxy composite electrode |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3376577/ https://www.ncbi.nlm.nih.gov/pubmed/22736991 http://dx.doi.org/10.3390/s120303037 |
work_keys_str_mv | AT ocanacristina areusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode AT paciosmerce areusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode AT delvallemanel areusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode AT ocanacristina reusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode AT paciosmerce reusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode AT delvallemanel reusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode |