Cargando…

A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode

Here, we report the application of a label-free electrochemical aptasensor based on a graphite-epoxy composite electrode for the detection of thrombin; in this work, aptamers were immobilized onto the electrodes surface using wet physical adsorption. The detection principle is based on the changes o...

Descripción completa

Detalles Bibliográficos
Autores principales: Ocaña, Cristina, Pacios, Mercè, del Valle, Manel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3376577/
https://www.ncbi.nlm.nih.gov/pubmed/22736991
http://dx.doi.org/10.3390/s120303037
_version_ 1782235846065258496
author Ocaña, Cristina
Pacios, Mercè
del Valle, Manel
author_facet Ocaña, Cristina
Pacios, Mercè
del Valle, Manel
author_sort Ocaña, Cristina
collection PubMed
description Here, we report the application of a label-free electrochemical aptasensor based on a graphite-epoxy composite electrode for the detection of thrombin; in this work, aptamers were immobilized onto the electrodes surface using wet physical adsorption. The detection principle is based on the changes of the interfacial properties of the electrode; these were probed in the presence of the reversible redox couple [Fe(CN)(6)](3−)/[Fe(CN)(6)](4−) using impedance measurements. The electrode surface was partially blocked due to formation of aptamer-thrombin complex, resulting in an increase of the interfacial electron-transfer resistance detected by Electrochemical Impedance Spectroscopy (EIS). The aptasensor showed a linear response for thrombin in the range of 7.5 pM to 75 pM and a detection limit of 4.5 pM. The aptasensor was regenerated by breaking the complex formed between the aptamer and thrombin using 2.0 M NaCl solution at 42 °C, showing its operation for different cycles. The interference response caused by main proteins in serum has been characterized.
format Online
Article
Text
id pubmed-3376577
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-33765772012-06-25 A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode Ocaña, Cristina Pacios, Mercè del Valle, Manel Sensors (Basel) Article Here, we report the application of a label-free electrochemical aptasensor based on a graphite-epoxy composite electrode for the detection of thrombin; in this work, aptamers were immobilized onto the electrodes surface using wet physical adsorption. The detection principle is based on the changes of the interfacial properties of the electrode; these were probed in the presence of the reversible redox couple [Fe(CN)(6)](3−)/[Fe(CN)(6)](4−) using impedance measurements. The electrode surface was partially blocked due to formation of aptamer-thrombin complex, resulting in an increase of the interfacial electron-transfer resistance detected by Electrochemical Impedance Spectroscopy (EIS). The aptasensor showed a linear response for thrombin in the range of 7.5 pM to 75 pM and a detection limit of 4.5 pM. The aptasensor was regenerated by breaking the complex formed between the aptamer and thrombin using 2.0 M NaCl solution at 42 °C, showing its operation for different cycles. The interference response caused by main proteins in serum has been characterized. Molecular Diversity Preservation International (MDPI) 2012-03-06 /pmc/articles/PMC3376577/ /pubmed/22736991 http://dx.doi.org/10.3390/s120303037 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Ocaña, Cristina
Pacios, Mercè
del Valle, Manel
A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
title A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
title_full A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
title_fullStr A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
title_full_unstemmed A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
title_short A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
title_sort reusable impedimetric aptasensor for detection of thrombin employing a graphite-epoxy composite electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3376577/
https://www.ncbi.nlm.nih.gov/pubmed/22736991
http://dx.doi.org/10.3390/s120303037
work_keys_str_mv AT ocanacristina areusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode
AT paciosmerce areusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode
AT delvallemanel areusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode
AT ocanacristina reusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode
AT paciosmerce reusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode
AT delvallemanel reusableimpedimetricaptasensorfordetectionofthrombinemployingagraphiteepoxycompositeelectrode