Cargando…

Electrical Characterization of Gold-DNA-Gold Structures in Presence of an External Magnetic Field by Means of I–V Curve Analysis

This work presents an experimental study of gold-DNA-gold structures in the presence and absence of external magnetic fields with strengths less than 1,200.00 mT. The DNA strands, extracted by standard method were used to fabricate a Metal-DNA-Metal (MDM) structure. Its electric behavior when subjec...

Descripción completa

Detalles Bibliográficos
Autores principales: Khatir, Nadia Mahmoudi, Banihashemian, Seyedeh Maryam, Periasamy, Vengadesh, Ritikos, Richard, Majid, Wan Haliza Abd, Rahman, Saadah Abdul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3376582/
https://www.ncbi.nlm.nih.gov/pubmed/22737025
http://dx.doi.org/10.3390/s120303578
_version_ 1782235847184089088
author Khatir, Nadia Mahmoudi
Banihashemian, Seyedeh Maryam
Periasamy, Vengadesh
Ritikos, Richard
Majid, Wan Haliza Abd
Rahman, Saadah Abdul
author_facet Khatir, Nadia Mahmoudi
Banihashemian, Seyedeh Maryam
Periasamy, Vengadesh
Ritikos, Richard
Majid, Wan Haliza Abd
Rahman, Saadah Abdul
author_sort Khatir, Nadia Mahmoudi
collection PubMed
description This work presents an experimental study of gold-DNA-gold structures in the presence and absence of external magnetic fields with strengths less than 1,200.00 mT. The DNA strands, extracted by standard method were used to fabricate a Metal-DNA-Metal (MDM) structure. Its electric behavior when subjected to a magnetic field was studied through its current-voltage (I–V) curve. Acquisition of the I–V curve demonstrated that DNA as a semiconductor exhibits diode behavior in the MDM structure. The current versus magnetic field strength followed a decreasing trend because of a diminished mobility in the presence of a low magnetic field. This made clear that an externally imposed magnetic field would boost resistance of the MDM structure up to 1,000.00 mT and for higher magnetic field strengths we can observe an increase in potential barrier in MDM junction. The magnetic sensitivity indicates the promise of using MDM structures as potential magnetic sensors.
format Online
Article
Text
id pubmed-3376582
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-33765822012-06-25 Electrical Characterization of Gold-DNA-Gold Structures in Presence of an External Magnetic Field by Means of I–V Curve Analysis Khatir, Nadia Mahmoudi Banihashemian, Seyedeh Maryam Periasamy, Vengadesh Ritikos, Richard Majid, Wan Haliza Abd Rahman, Saadah Abdul Sensors (Basel) Article This work presents an experimental study of gold-DNA-gold structures in the presence and absence of external magnetic fields with strengths less than 1,200.00 mT. The DNA strands, extracted by standard method were used to fabricate a Metal-DNA-Metal (MDM) structure. Its electric behavior when subjected to a magnetic field was studied through its current-voltage (I–V) curve. Acquisition of the I–V curve demonstrated that DNA as a semiconductor exhibits diode behavior in the MDM structure. The current versus magnetic field strength followed a decreasing trend because of a diminished mobility in the presence of a low magnetic field. This made clear that an externally imposed magnetic field would boost resistance of the MDM structure up to 1,000.00 mT and for higher magnetic field strengths we can observe an increase in potential barrier in MDM junction. The magnetic sensitivity indicates the promise of using MDM structures as potential magnetic sensors. Molecular Diversity Preservation International (MDPI) 2012-03-14 /pmc/articles/PMC3376582/ /pubmed/22737025 http://dx.doi.org/10.3390/s120303578 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Khatir, Nadia Mahmoudi
Banihashemian, Seyedeh Maryam
Periasamy, Vengadesh
Ritikos, Richard
Majid, Wan Haliza Abd
Rahman, Saadah Abdul
Electrical Characterization of Gold-DNA-Gold Structures in Presence of an External Magnetic Field by Means of I–V Curve Analysis
title Electrical Characterization of Gold-DNA-Gold Structures in Presence of an External Magnetic Field by Means of I–V Curve Analysis
title_full Electrical Characterization of Gold-DNA-Gold Structures in Presence of an External Magnetic Field by Means of I–V Curve Analysis
title_fullStr Electrical Characterization of Gold-DNA-Gold Structures in Presence of an External Magnetic Field by Means of I–V Curve Analysis
title_full_unstemmed Electrical Characterization of Gold-DNA-Gold Structures in Presence of an External Magnetic Field by Means of I–V Curve Analysis
title_short Electrical Characterization of Gold-DNA-Gold Structures in Presence of an External Magnetic Field by Means of I–V Curve Analysis
title_sort electrical characterization of gold-dna-gold structures in presence of an external magnetic field by means of i–v curve analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3376582/
https://www.ncbi.nlm.nih.gov/pubmed/22737025
http://dx.doi.org/10.3390/s120303578
work_keys_str_mv AT khatirnadiamahmoudi electricalcharacterizationofgolddnagoldstructuresinpresenceofanexternalmagneticfieldbymeansofivcurveanalysis
AT banihashemianseyedehmaryam electricalcharacterizationofgolddnagoldstructuresinpresenceofanexternalmagneticfieldbymeansofivcurveanalysis
AT periasamyvengadesh electricalcharacterizationofgolddnagoldstructuresinpresenceofanexternalmagneticfieldbymeansofivcurveanalysis
AT ritikosrichard electricalcharacterizationofgolddnagoldstructuresinpresenceofanexternalmagneticfieldbymeansofivcurveanalysis
AT majidwanhalizaabd electricalcharacterizationofgolddnagoldstructuresinpresenceofanexternalmagneticfieldbymeansofivcurveanalysis
AT rahmansaadahabdul electricalcharacterizationofgolddnagoldstructuresinpresenceofanexternalmagneticfieldbymeansofivcurveanalysis