Cargando…

Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study

BACKGROUND: Different types of devices are available and the choice about which to use depends on various factors: cost, physical characteristics, performance, and the validity and intra- and interinstrument reliability. Given the large number of studies that have used uniaxial or triaxial devices,...

Descripción completa

Detalles Bibliográficos
Autores principales: Vanhelst, Jérémy, Béghin, Laurent, Duhamel, Alain, Bergman, Patrick, Sjöström, Michael, Gottrand, Frédéric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3378459/
https://www.ncbi.nlm.nih.gov/pubmed/22409718
http://dx.doi.org/10.1186/1471-2288-12-26
_version_ 1782236040665235456
author Vanhelst, Jérémy
Béghin, Laurent
Duhamel, Alain
Bergman, Patrick
Sjöström, Michael
Gottrand, Frédéric
author_facet Vanhelst, Jérémy
Béghin, Laurent
Duhamel, Alain
Bergman, Patrick
Sjöström, Michael
Gottrand, Frédéric
author_sort Vanhelst, Jérémy
collection PubMed
description BACKGROUND: Different types of devices are available and the choice about which to use depends on various factors: cost, physical characteristics, performance, and the validity and intra- and interinstrument reliability. Given the large number of studies that have used uniaxial or triaxial devices, it is of interest to know whether the different devices give similar information about PA levels and patterns. The aim of this study was to compare physical activity (PA) levels and patterns obtained simultaneously by triaxial accelerometry and uniaxial accelerometry in adolescents in free-living conditions. METHODS: Sixty-two participants, aged 13-16 years, were recruited in this ancillary study, which is a part of the Healthy Lifestyle in Europe by Nutrition in Adolescence (HELENA). All participants wore a uniaxial accelerometer (ActiGraph GT1M(®), Pensacola, FL) and a triaxial accelerometer (RT3(®), Stayhealthy, Monrovia, CA) simultaneously for 7 days. The patterns were calculated by converting accelerometer data output as a percentage of time spent at sedentary, light, moderate, and vigorous PA per day. Analysis of output data from the two accelerometers were assessed by two different tests: Equivalence Test and Bland & Altman method. RESULTS: The concordance correlation coefficient between the data from the triaxial accelerometer and uniaxial accelerometer at each intensity level was superior to 0.95. The ANOVA test showed a significant difference for the first three lower intensities while no significant difference was found for vigorous intensity. The difference between data obtained with the triaxial accelerometer and the uniaxial monitor never exceeded 2.1% and decreased as PA level increased. The Bland & Altman method showed good agreement between data obtained between the both accelerometers (p < 0.05). CONCLUSIONS: Uniaxial and triaxial accelerometers do not differ in their measurement of PA in population studies, and either could be used in such studies.
format Online
Article
Text
id pubmed-3378459
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33784592012-06-20 Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study Vanhelst, Jérémy Béghin, Laurent Duhamel, Alain Bergman, Patrick Sjöström, Michael Gottrand, Frédéric BMC Med Res Methodol Research Article BACKGROUND: Different types of devices are available and the choice about which to use depends on various factors: cost, physical characteristics, performance, and the validity and intra- and interinstrument reliability. Given the large number of studies that have used uniaxial or triaxial devices, it is of interest to know whether the different devices give similar information about PA levels and patterns. The aim of this study was to compare physical activity (PA) levels and patterns obtained simultaneously by triaxial accelerometry and uniaxial accelerometry in adolescents in free-living conditions. METHODS: Sixty-two participants, aged 13-16 years, were recruited in this ancillary study, which is a part of the Healthy Lifestyle in Europe by Nutrition in Adolescence (HELENA). All participants wore a uniaxial accelerometer (ActiGraph GT1M(®), Pensacola, FL) and a triaxial accelerometer (RT3(®), Stayhealthy, Monrovia, CA) simultaneously for 7 days. The patterns were calculated by converting accelerometer data output as a percentage of time spent at sedentary, light, moderate, and vigorous PA per day. Analysis of output data from the two accelerometers were assessed by two different tests: Equivalence Test and Bland & Altman method. RESULTS: The concordance correlation coefficient between the data from the triaxial accelerometer and uniaxial accelerometer at each intensity level was superior to 0.95. The ANOVA test showed a significant difference for the first three lower intensities while no significant difference was found for vigorous intensity. The difference between data obtained with the triaxial accelerometer and the uniaxial monitor never exceeded 2.1% and decreased as PA level increased. The Bland & Altman method showed good agreement between data obtained between the both accelerometers (p < 0.05). CONCLUSIONS: Uniaxial and triaxial accelerometers do not differ in their measurement of PA in population studies, and either could be used in such studies. BioMed Central 2012-03-12 /pmc/articles/PMC3378459/ /pubmed/22409718 http://dx.doi.org/10.1186/1471-2288-12-26 Text en Copyright ©2012 Vanhelst et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Vanhelst, Jérémy
Béghin, Laurent
Duhamel, Alain
Bergman, Patrick
Sjöström, Michael
Gottrand, Frédéric
Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study
title Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study
title_full Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study
title_fullStr Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study
title_full_unstemmed Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study
title_short Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study
title_sort comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the helena study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3378459/
https://www.ncbi.nlm.nih.gov/pubmed/22409718
http://dx.doi.org/10.1186/1471-2288-12-26
work_keys_str_mv AT vanhelstjeremy comparisonofuniaxialandtriaxialaccelerometryintheassessmentofphysicalactivityamongadolescentsunderfreelivingconditionsthehelenastudy
AT beghinlaurent comparisonofuniaxialandtriaxialaccelerometryintheassessmentofphysicalactivityamongadolescentsunderfreelivingconditionsthehelenastudy
AT duhamelalain comparisonofuniaxialandtriaxialaccelerometryintheassessmentofphysicalactivityamongadolescentsunderfreelivingconditionsthehelenastudy
AT bergmanpatrick comparisonofuniaxialandtriaxialaccelerometryintheassessmentofphysicalactivityamongadolescentsunderfreelivingconditionsthehelenastudy
AT sjostrommichael comparisonofuniaxialandtriaxialaccelerometryintheassessmentofphysicalactivityamongadolescentsunderfreelivingconditionsthehelenastudy
AT gottrandfrederic comparisonofuniaxialandtriaxialaccelerometryintheassessmentofphysicalactivityamongadolescentsunderfreelivingconditionsthehelenastudy