Cargando…
Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound
PURPOSE: Accurate evaluation of side branch (SB) ostium could be critical to the treatment of bifurcation lesions. We compared measured and calculated values of side branch ostial length (SBOL) in coronary bifurcation lesions with intravascular ultrasound (IVUS). MATERIALS AND METHODS: Pre-intervent...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3381491/ https://www.ncbi.nlm.nih.gov/pubmed/22665331 http://dx.doi.org/10.3349/ymj.2012.53.4.680 |
_version_ | 1782236407792664576 |
---|---|
author | Ryu, Hyeon Min Kim, Byeong-Keuk Kim, Jung-Sun Ko, Young-Guk Choi, Donghoon Jang, Yangsoo Hong, Myeong-Ki |
author_facet | Ryu, Hyeon Min Kim, Byeong-Keuk Kim, Jung-Sun Ko, Young-Guk Choi, Donghoon Jang, Yangsoo Hong, Myeong-Ki |
author_sort | Ryu, Hyeon Min |
collection | PubMed |
description | PURPOSE: Accurate evaluation of side branch (SB) ostium could be critical to the treatment of bifurcation lesions. We compared measured and calculated values of side branch ostial length (SBOL) in coronary bifurcation lesions with intravascular ultrasound (IVUS). MATERIALS AND METHODS: Pre-intervention and post-intervention IVUS was performed in 113 patients who underwent stent implantation of bifurcation lesions. For the IVUS longitudinal reconstruction of the bifurcation lesions, SBOL, SB diameter, and the angle between the distal portion of the main vessel (MV) and SB were directly measured. In addition, SBOL was calculated as: SB diameter/sin (angle between distal MV and SB). The relationship between measured and calculated SBOL was then evaluated. RESULTS: The angled between the distal MV and SB were 57.3±12.4° at pre-intervention and 59.4±12.6° at post-intervention. The mean measured and calculated SBOL values were 2.91±0.86 mm and 3.06±0.77 mm at pre-intervention and 2.79±0.82 mm and 2.92±0.69 mm at post-intervention, respectively. Differences between measured and calculated SBOL were 0.15±0.44 mm at pre-intervention and 0.13±0.41 mm at post-intervention. We found that calculated SBOL was correlated with measured SBOL (pre-intervention r=0.863, p<0.001; post-intervention r=0.868, p<0.001). CONCLUSION: There was a good correlation between measured and calculated SBOLs of the bifurcation lesions in IVUS longitudinal reconstruction. SBOL in the bifurcation lesions can therefore be estimated using the SB diameter and the angle between distal MV and SB. |
format | Online Article Text |
id | pubmed-3381491 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-33814912012-07-01 Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound Ryu, Hyeon Min Kim, Byeong-Keuk Kim, Jung-Sun Ko, Young-Guk Choi, Donghoon Jang, Yangsoo Hong, Myeong-Ki Yonsei Med J Original Article PURPOSE: Accurate evaluation of side branch (SB) ostium could be critical to the treatment of bifurcation lesions. We compared measured and calculated values of side branch ostial length (SBOL) in coronary bifurcation lesions with intravascular ultrasound (IVUS). MATERIALS AND METHODS: Pre-intervention and post-intervention IVUS was performed in 113 patients who underwent stent implantation of bifurcation lesions. For the IVUS longitudinal reconstruction of the bifurcation lesions, SBOL, SB diameter, and the angle between the distal portion of the main vessel (MV) and SB were directly measured. In addition, SBOL was calculated as: SB diameter/sin (angle between distal MV and SB). The relationship between measured and calculated SBOL was then evaluated. RESULTS: The angled between the distal MV and SB were 57.3±12.4° at pre-intervention and 59.4±12.6° at post-intervention. The mean measured and calculated SBOL values were 2.91±0.86 mm and 3.06±0.77 mm at pre-intervention and 2.79±0.82 mm and 2.92±0.69 mm at post-intervention, respectively. Differences between measured and calculated SBOL were 0.15±0.44 mm at pre-intervention and 0.13±0.41 mm at post-intervention. We found that calculated SBOL was correlated with measured SBOL (pre-intervention r=0.863, p<0.001; post-intervention r=0.868, p<0.001). CONCLUSION: There was a good correlation between measured and calculated SBOLs of the bifurcation lesions in IVUS longitudinal reconstruction. SBOL in the bifurcation lesions can therefore be estimated using the SB diameter and the angle between distal MV and SB. Yonsei University College of Medicine 2012-07-01 2012-05-22 /pmc/articles/PMC3381491/ /pubmed/22665331 http://dx.doi.org/10.3349/ymj.2012.53.4.680 Text en © Copyright: Yonsei University College of Medicine 2012 http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ryu, Hyeon Min Kim, Byeong-Keuk Kim, Jung-Sun Ko, Young-Guk Choi, Donghoon Jang, Yangsoo Hong, Myeong-Ki Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound |
title | Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound |
title_full | Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound |
title_fullStr | Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound |
title_full_unstemmed | Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound |
title_short | Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound |
title_sort | comparison between measured and calculated length of side branch ostium in coronary bifurcation lesions with intravascular ultrasound |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3381491/ https://www.ncbi.nlm.nih.gov/pubmed/22665331 http://dx.doi.org/10.3349/ymj.2012.53.4.680 |
work_keys_str_mv | AT ryuhyeonmin comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound AT kimbyeongkeuk comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound AT kimjungsun comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound AT koyoungguk comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound AT choidonghoon comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound AT jangyangsoo comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound AT hongmyeongki comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound |