Cargando…

Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound

PURPOSE: Accurate evaluation of side branch (SB) ostium could be critical to the treatment of bifurcation lesions. We compared measured and calculated values of side branch ostial length (SBOL) in coronary bifurcation lesions with intravascular ultrasound (IVUS). MATERIALS AND METHODS: Pre-intervent...

Descripción completa

Detalles Bibliográficos
Autores principales: Ryu, Hyeon Min, Kim, Byeong-Keuk, Kim, Jung-Sun, Ko, Young-Guk, Choi, Donghoon, Jang, Yangsoo, Hong, Myeong-Ki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3381491/
https://www.ncbi.nlm.nih.gov/pubmed/22665331
http://dx.doi.org/10.3349/ymj.2012.53.4.680
_version_ 1782236407792664576
author Ryu, Hyeon Min
Kim, Byeong-Keuk
Kim, Jung-Sun
Ko, Young-Guk
Choi, Donghoon
Jang, Yangsoo
Hong, Myeong-Ki
author_facet Ryu, Hyeon Min
Kim, Byeong-Keuk
Kim, Jung-Sun
Ko, Young-Guk
Choi, Donghoon
Jang, Yangsoo
Hong, Myeong-Ki
author_sort Ryu, Hyeon Min
collection PubMed
description PURPOSE: Accurate evaluation of side branch (SB) ostium could be critical to the treatment of bifurcation lesions. We compared measured and calculated values of side branch ostial length (SBOL) in coronary bifurcation lesions with intravascular ultrasound (IVUS). MATERIALS AND METHODS: Pre-intervention and post-intervention IVUS was performed in 113 patients who underwent stent implantation of bifurcation lesions. For the IVUS longitudinal reconstruction of the bifurcation lesions, SBOL, SB diameter, and the angle between the distal portion of the main vessel (MV) and SB were directly measured. In addition, SBOL was calculated as: SB diameter/sin (angle between distal MV and SB). The relationship between measured and calculated SBOL was then evaluated. RESULTS: The angled between the distal MV and SB were 57.3±12.4° at pre-intervention and 59.4±12.6° at post-intervention. The mean measured and calculated SBOL values were 2.91±0.86 mm and 3.06±0.77 mm at pre-intervention and 2.79±0.82 mm and 2.92±0.69 mm at post-intervention, respectively. Differences between measured and calculated SBOL were 0.15±0.44 mm at pre-intervention and 0.13±0.41 mm at post-intervention. We found that calculated SBOL was correlated with measured SBOL (pre-intervention r=0.863, p<0.001; post-intervention r=0.868, p<0.001). CONCLUSION: There was a good correlation between measured and calculated SBOLs of the bifurcation lesions in IVUS longitudinal reconstruction. SBOL in the bifurcation lesions can therefore be estimated using the SB diameter and the angle between distal MV and SB.
format Online
Article
Text
id pubmed-3381491
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-33814912012-07-01 Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound Ryu, Hyeon Min Kim, Byeong-Keuk Kim, Jung-Sun Ko, Young-Guk Choi, Donghoon Jang, Yangsoo Hong, Myeong-Ki Yonsei Med J Original Article PURPOSE: Accurate evaluation of side branch (SB) ostium could be critical to the treatment of bifurcation lesions. We compared measured and calculated values of side branch ostial length (SBOL) in coronary bifurcation lesions with intravascular ultrasound (IVUS). MATERIALS AND METHODS: Pre-intervention and post-intervention IVUS was performed in 113 patients who underwent stent implantation of bifurcation lesions. For the IVUS longitudinal reconstruction of the bifurcation lesions, SBOL, SB diameter, and the angle between the distal portion of the main vessel (MV) and SB were directly measured. In addition, SBOL was calculated as: SB diameter/sin (angle between distal MV and SB). The relationship between measured and calculated SBOL was then evaluated. RESULTS: The angled between the distal MV and SB were 57.3±12.4° at pre-intervention and 59.4±12.6° at post-intervention. The mean measured and calculated SBOL values were 2.91±0.86 mm and 3.06±0.77 mm at pre-intervention and 2.79±0.82 mm and 2.92±0.69 mm at post-intervention, respectively. Differences between measured and calculated SBOL were 0.15±0.44 mm at pre-intervention and 0.13±0.41 mm at post-intervention. We found that calculated SBOL was correlated with measured SBOL (pre-intervention r=0.863, p<0.001; post-intervention r=0.868, p<0.001). CONCLUSION: There was a good correlation between measured and calculated SBOLs of the bifurcation lesions in IVUS longitudinal reconstruction. SBOL in the bifurcation lesions can therefore be estimated using the SB diameter and the angle between distal MV and SB. Yonsei University College of Medicine 2012-07-01 2012-05-22 /pmc/articles/PMC3381491/ /pubmed/22665331 http://dx.doi.org/10.3349/ymj.2012.53.4.680 Text en © Copyright: Yonsei University College of Medicine 2012 http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ryu, Hyeon Min
Kim, Byeong-Keuk
Kim, Jung-Sun
Ko, Young-Guk
Choi, Donghoon
Jang, Yangsoo
Hong, Myeong-Ki
Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound
title Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound
title_full Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound
title_fullStr Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound
title_full_unstemmed Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound
title_short Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound
title_sort comparison between measured and calculated length of side branch ostium in coronary bifurcation lesions with intravascular ultrasound
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3381491/
https://www.ncbi.nlm.nih.gov/pubmed/22665331
http://dx.doi.org/10.3349/ymj.2012.53.4.680
work_keys_str_mv AT ryuhyeonmin comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound
AT kimbyeongkeuk comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound
AT kimjungsun comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound
AT koyoungguk comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound
AT choidonghoon comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound
AT jangyangsoo comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound
AT hongmyeongki comparisonbetweenmeasuredandcalculatedlengthofsidebranchostiumincoronarybifurcationlesionswithintravascularultrasound