Cargando…

Stability-Indicating HPLC Method for Posaconazole Bulk Assay

A stability-indicating liquid chromatographic (LC) method was developed for the determination of posaconazole in bulk. Chromatographic separation was achieved using an isocratic elution in a reversed-phase system, with a mobile phase composed of methanol-water (75:25, v/v), at 1.0 mL min(−1) flow. S...

Descripción completa

Detalles Bibliográficos
Autores principales: Garcia, Cássia V., Costa, Gislaine R., Mendez, Andreas S. L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Österreichische Apotheker-Verlagsgesellschaft 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3383215/
https://www.ncbi.nlm.nih.gov/pubmed/22896819
http://dx.doi.org/10.3797/scipharm.1111-11
_version_ 1782236594459115520
author Garcia, Cássia V.
Costa, Gislaine R.
Mendez, Andreas S. L.
author_facet Garcia, Cássia V.
Costa, Gislaine R.
Mendez, Andreas S. L.
author_sort Garcia, Cássia V.
collection PubMed
description A stability-indicating liquid chromatographic (LC) method was developed for the determination of posaconazole in bulk. Chromatographic separation was achieved using an isocratic elution in a reversed-phase system, with a mobile phase composed of methanol-water (75:25, v/v), at 1.0 mL min(−1) flow. Samples were exposed to degradation under thermal, oxidative and acid/basic conditions, and no interference in the analysis was observed. System suitability was evaluated and results were satisfactory (N = 4,900.00 tailing factor 1.04; RSD between injections = 0.65). The retention time of posaconazole was about 8.5 min and the method was validated within the concentration range 5–60 μg mL(−1) (r = 0.9996). Adequate results were obtained for repeatability (RSD % = 0.86–1.22), inter-day precision (RSD % = 1.21) and accuracy (98.13% mean recovery). Robustness was also determined to be satisfactory after evaluation. The proposed method was successfully applied to posaconazole bulk quantification, showing the method is useful for determination of the drug in routine analysis.
format Online
Article
Text
id pubmed-3383215
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Österreichische Apotheker-Verlagsgesellschaft
record_format MEDLINE/PubMed
spelling pubmed-33832152012-08-15 Stability-Indicating HPLC Method for Posaconazole Bulk Assay Garcia, Cássia V. Costa, Gislaine R. Mendez, Andreas S. L. Sci Pharm Research Article A stability-indicating liquid chromatographic (LC) method was developed for the determination of posaconazole in bulk. Chromatographic separation was achieved using an isocratic elution in a reversed-phase system, with a mobile phase composed of methanol-water (75:25, v/v), at 1.0 mL min(−1) flow. Samples were exposed to degradation under thermal, oxidative and acid/basic conditions, and no interference in the analysis was observed. System suitability was evaluated and results were satisfactory (N = 4,900.00 tailing factor 1.04; RSD between injections = 0.65). The retention time of posaconazole was about 8.5 min and the method was validated within the concentration range 5–60 μg mL(−1) (r = 0.9996). Adequate results were obtained for repeatability (RSD % = 0.86–1.22), inter-day precision (RSD % = 1.21) and accuracy (98.13% mean recovery). Robustness was also determined to be satisfactory after evaluation. The proposed method was successfully applied to posaconazole bulk quantification, showing the method is useful for determination of the drug in routine analysis. Österreichische Apotheker-Verlagsgesellschaft 2012 2012-03-12 /pmc/articles/PMC3383215/ /pubmed/22896819 http://dx.doi.org/10.3797/scipharm.1111-11 Text en © Garcia et al.; licensee Österreichische Apotheker-Verlagsgesellschaft m. b. H., Vienna, Austria. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Garcia, Cássia V.
Costa, Gislaine R.
Mendez, Andreas S. L.
Stability-Indicating HPLC Method for Posaconazole Bulk Assay
title Stability-Indicating HPLC Method for Posaconazole Bulk Assay
title_full Stability-Indicating HPLC Method for Posaconazole Bulk Assay
title_fullStr Stability-Indicating HPLC Method for Posaconazole Bulk Assay
title_full_unstemmed Stability-Indicating HPLC Method for Posaconazole Bulk Assay
title_short Stability-Indicating HPLC Method for Posaconazole Bulk Assay
title_sort stability-indicating hplc method for posaconazole bulk assay
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3383215/
https://www.ncbi.nlm.nih.gov/pubmed/22896819
http://dx.doi.org/10.3797/scipharm.1111-11
work_keys_str_mv AT garciacassiav stabilityindicatinghplcmethodforposaconazolebulkassay
AT costagislainer stabilityindicatinghplcmethodforposaconazolebulkassay
AT mendezandreassl stabilityindicatinghplcmethodforposaconazolebulkassay