Cargando…
Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials
BACKGROUND: Commutable reference materials (RMs) are suitable for end-users for evaluating the metrological traceability of values obtained using routine measurement systems. We assessed the performance of 6 routine measurement systems with validated secondary RMs. METHODS: We tested the homogeneity...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3384804/ https://www.ncbi.nlm.nih.gov/pubmed/22779064 http://dx.doi.org/10.3343/alm.2012.32.4.243 |
_version_ | 1782236750597324800 |
---|---|
author | Xia, ChangYu Liu, Ou Wang, LanZhen Xu, GuoBing |
author_facet | Xia, ChangYu Liu, Ou Wang, LanZhen Xu, GuoBing |
author_sort | Xia, ChangYu |
collection | PubMed |
description | BACKGROUND: Commutable reference materials (RMs) are suitable for end-users for evaluating the metrological traceability of values obtained using routine measurement systems. We assessed the performance of 6 routine measurement systems with validated secondary RMs. METHODS: We tested the homogeneity, stability, and commutability of 5 minimally processed human serum pools according to the standard guidelines. The serum pools were assigned values as per the reference procedure of the United States Centers for Disease Control and were used to evaluate the trueness of results from 6 commercial measurement systems based on enzymatic methods: 3 glucose oxidase (GOD) and 3 hexokinase (HK) methods. RESULTS: The prepared RMs were validated to be sufficiently homogenous, stable, and commutable with the patient samples. Method bias varied for different systems: GOD01, -0.17 to 2.88%; GOD02, 1.66 to 4.58%; GOD03, -0.17 to 3.14%; HK01, -3.48 to -0.85%; HK02, -3.83 to -0.11%, and HK03, -1.82 to -0.27%. CONCLUSIONS: We observed that the prepared serum glucose RMs were qualified for trueness assessment. Most of the measurement systems met the minimal quality specifications. |
format | Online Article Text |
id | pubmed-3384804 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-33848042012-07-10 Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials Xia, ChangYu Liu, Ou Wang, LanZhen Xu, GuoBing Ann Lab Med Original Article BACKGROUND: Commutable reference materials (RMs) are suitable for end-users for evaluating the metrological traceability of values obtained using routine measurement systems. We assessed the performance of 6 routine measurement systems with validated secondary RMs. METHODS: We tested the homogeneity, stability, and commutability of 5 minimally processed human serum pools according to the standard guidelines. The serum pools were assigned values as per the reference procedure of the United States Centers for Disease Control and were used to evaluate the trueness of results from 6 commercial measurement systems based on enzymatic methods: 3 glucose oxidase (GOD) and 3 hexokinase (HK) methods. RESULTS: The prepared RMs were validated to be sufficiently homogenous, stable, and commutable with the patient samples. Method bias varied for different systems: GOD01, -0.17 to 2.88%; GOD02, 1.66 to 4.58%; GOD03, -0.17 to 3.14%; HK01, -3.48 to -0.85%; HK02, -3.83 to -0.11%, and HK03, -1.82 to -0.27%. CONCLUSIONS: We observed that the prepared serum glucose RMs were qualified for trueness assessment. Most of the measurement systems met the minimal quality specifications. The Korean Society for Laboratory Medicine 2012-07 2012-06-20 /pmc/articles/PMC3384804/ /pubmed/22779064 http://dx.doi.org/10.3343/alm.2012.32.4.243 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Xia, ChangYu Liu, Ou Wang, LanZhen Xu, GuoBing Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials |
title | Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials |
title_full | Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials |
title_fullStr | Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials |
title_full_unstemmed | Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials |
title_short | Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials |
title_sort | trueness assessment for serum glucose measurement using commercial systems through the preparation of commutable reference materials |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3384804/ https://www.ncbi.nlm.nih.gov/pubmed/22779064 http://dx.doi.org/10.3343/alm.2012.32.4.243 |
work_keys_str_mv | AT xiachangyu truenessassessmentforserumglucosemeasurementusingcommercialsystemsthroughthepreparationofcommutablereferencematerials AT liuou truenessassessmentforserumglucosemeasurementusingcommercialsystemsthroughthepreparationofcommutablereferencematerials AT wanglanzhen truenessassessmentforserumglucosemeasurementusingcommercialsystemsthroughthepreparationofcommutablereferencematerials AT xuguobing truenessassessmentforserumglucosemeasurementusingcommercialsystemsthroughthepreparationofcommutablereferencematerials |