Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials

BACKGROUND: Commutable reference materials (RMs) are suitable for end-users for evaluating the metrological traceability of values obtained using routine measurement systems. We assessed the performance of 6 routine measurement systems with validated secondary RMs. METHODS: We tested the homogeneity...

Descripción completa

Detalles Bibliográficos
Autores principales: Xia, ChangYu, Liu, Ou, Wang, LanZhen, Xu, GuoBing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3384804/
https://www.ncbi.nlm.nih.gov/pubmed/22779064
http://dx.doi.org/10.3343/alm.2012.32.4.243
_version_ 1782236750597324800
author Xia, ChangYu
Liu, Ou
Wang, LanZhen
Xu, GuoBing
author_facet Xia, ChangYu
Liu, Ou
Wang, LanZhen
Xu, GuoBing
author_sort Xia, ChangYu
collection PubMed
description BACKGROUND: Commutable reference materials (RMs) are suitable for end-users for evaluating the metrological traceability of values obtained using routine measurement systems. We assessed the performance of 6 routine measurement systems with validated secondary RMs. METHODS: We tested the homogeneity, stability, and commutability of 5 minimally processed human serum pools according to the standard guidelines. The serum pools were assigned values as per the reference procedure of the United States Centers for Disease Control and were used to evaluate the trueness of results from 6 commercial measurement systems based on enzymatic methods: 3 glucose oxidase (GOD) and 3 hexokinase (HK) methods. RESULTS: The prepared RMs were validated to be sufficiently homogenous, stable, and commutable with the patient samples. Method bias varied for different systems: GOD01, -0.17 to 2.88%; GOD02, 1.66 to 4.58%; GOD03, -0.17 to 3.14%; HK01, -3.48 to -0.85%; HK02, -3.83 to -0.11%, and HK03, -1.82 to -0.27%. CONCLUSIONS: We observed that the prepared serum glucose RMs were qualified for trueness assessment. Most of the measurement systems met the minimal quality specifications.
format Online
Article
Text
id pubmed-3384804
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-33848042012-07-10 Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials Xia, ChangYu Liu, Ou Wang, LanZhen Xu, GuoBing Ann Lab Med Original Article BACKGROUND: Commutable reference materials (RMs) are suitable for end-users for evaluating the metrological traceability of values obtained using routine measurement systems. We assessed the performance of 6 routine measurement systems with validated secondary RMs. METHODS: We tested the homogeneity, stability, and commutability of 5 minimally processed human serum pools according to the standard guidelines. The serum pools were assigned values as per the reference procedure of the United States Centers for Disease Control and were used to evaluate the trueness of results from 6 commercial measurement systems based on enzymatic methods: 3 glucose oxidase (GOD) and 3 hexokinase (HK) methods. RESULTS: The prepared RMs were validated to be sufficiently homogenous, stable, and commutable with the patient samples. Method bias varied for different systems: GOD01, -0.17 to 2.88%; GOD02, 1.66 to 4.58%; GOD03, -0.17 to 3.14%; HK01, -3.48 to -0.85%; HK02, -3.83 to -0.11%, and HK03, -1.82 to -0.27%. CONCLUSIONS: We observed that the prepared serum glucose RMs were qualified for trueness assessment. Most of the measurement systems met the minimal quality specifications. The Korean Society for Laboratory Medicine 2012-07 2012-06-20 /pmc/articles/PMC3384804/ /pubmed/22779064 http://dx.doi.org/10.3343/alm.2012.32.4.243 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Xia, ChangYu
Liu, Ou
Wang, LanZhen
Xu, GuoBing
Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials
title Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials
title_full Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials
title_fullStr Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials
title_full_unstemmed Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials
title_short Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials
title_sort trueness assessment for serum glucose measurement using commercial systems through the preparation of commutable reference materials
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3384804/
https://www.ncbi.nlm.nih.gov/pubmed/22779064
http://dx.doi.org/10.3343/alm.2012.32.4.243
work_keys_str_mv AT xiachangyu truenessassessmentforserumglucosemeasurementusingcommercialsystemsthroughthepreparationofcommutablereferencematerials
AT liuou truenessassessmentforserumglucosemeasurementusingcommercialsystemsthroughthepreparationofcommutablereferencematerials
AT wanglanzhen truenessassessmentforserumglucosemeasurementusingcommercialsystemsthroughthepreparationofcommutablereferencematerials
AT xuguobing truenessassessmentforserumglucosemeasurementusingcommercialsystemsthroughthepreparationofcommutablereferencematerials